• Title/Summary/Keyword: performance evaluation and design

Search Result 3,796, Processing Time 0.035 seconds

A New Generic Petri Net Model for Design and Performance Evaluation of JIT Flexible Manufacturing and Assembly

  • Seeluangsawat, Roongrat;Bohez, Erik L.J.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.963-966
    • /
    • 2002
  • This paper presents a new generic Petri net model for design and performance evaluation of a flexible assembly system with dual kanban. The architectural design of the model is derived from a generic bill of materials and the combination of FMS and FAS concepts. Two approaches for analysis and performance evaluation of the new model base on the theory of invariant analysis and linear programming are also introduced. Finally, the effect of different processing times between FMS-FAS on the number of kanban cards is investigated.

  • PDF

Numerical Range Criteria for Classification of Value Engineering Proposals based on Value Improvement Types (VE제안의 가치향상 유형별 수치적 범위기준 제시)

  • Nam, Keong-Woo;Jang, Myunghoun
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.287-294
    • /
    • 2018
  • Since its introduction in Korea, design VE has widely been used as a means to enhance values in the construction industry. However, a greater emphasis is still placed on cost reduction in approach attitudes and performance evaluations on the implementation of design VE. In this regard, this study presented a performance evaluation method for cost, function, and value of VE proposals. Numerical criteria on the increase and decrease of cost and function that can classify the value enhancement type of VE proposals were proposed based on the performance evaluation method. It is expected that the use of numerical criteria for the type classification of VE proposal, and cost and performance evaluation method proposed in this study will make it possible to conduct a clear and more intuitive evaluation of VE proposal. However, it is appropriate to use the numerical criteria as a guideline to apply the new performance evaluation method for VE proposals. Therefore, it is necessary to conduct a statistical analysis with a wider range of users after the repeated application of the findings of this study, and thus to carry out research for presenting the numerical criteria for various types of users.

Performance-measure of the domestic web site design (국내 웹 사이트 디자인의 행동적 사용성 측정)

  • Gwak, Ho-Wan;Gwak, Ji-Eun;Kim, Su-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.87-103
    • /
    • 1999
  • The present study employed an experimental usability testing technique to explore cognitive engineering characteristics of WWW. Based on the results of our previous study which employed non-experimental methods such as questionnaire and heuristic evaluation method, this study used a behavioral performance-measurement technique to evaluate the usability of a domestic web-site design. Specifically, we revised the menu and document structure of the original 'Movie-Friend' site to solve the design problems which were extracted from the results of the heuristic evaluation method of our previous study. Exp. 1 compared the relative navigation efficiency of the original frame menu site and the revised pop-up toolbar site, and Exp. 2 compared the toolbar menu site and the revised frame site. As a result of Exp. 1, the revised pop-up toolbar site showed improved navigation efficiency compared to the original site, as indicated by the mean latency and the number of pathways to reach the target page. However, we found no performance difference between the frame site and toolbar site in Exp. 2.

  • PDF

Proposed Seismic Performance Evaluation Enhancement for Existing School Building (기존 학교 건축물의 내진성능평가 및 보강방안 제안)

  • Hwang, Ji-Hoon;Jang, Jeong-Hyun;Yang, Kyeong-Seok;Choi, Jae-Hyouk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.4
    • /
    • pp.29-38
    • /
    • 2012
  • Recently large scale earthquake s are occurred around the world following the damage of buildings. So the interest of preparing for earthquake seismic design and seismic performance has becoming high. School buildings are though used for educational purpose; they are also used as emergency shelter for local residents during earthquake disaster. However, the current seismic design ratio of our country (Korea) is 3.7% and if massive earthquake is occurred it follows a serious damage. In order to overcome this situation, seismic performance evaluation is carried out for existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear static analysis on existing school buildings for ATC-40 and FEMA-356 are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to verify the effect of retrofit enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effect of seismic retrofit time history analysis using nonlinear dynamic analysis is also performed and nonlinear behavior of earthquake load of seismic retrofit of structures was also investigated.

Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change - (공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 -)

  • Ye, Tae-Gon;Kim, Kwang-Hyun;Kwon, Young-Sang
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.1
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.

Verification of diaphragm seismic design factors for precast concrete parking structures

  • Zhang, Dichuan;Fleischman, Robert
    • Structural Engineering and Mechanics
    • /
    • v.71 no.6
    • /
    • pp.643-656
    • /
    • 2019
  • A new seismic design methodology was proposed for precast concrete diaphragms. This methodology adopts seismic design factors applied on top of current diaphragm design forces. These factors are aimed to produce diaphragm design strengths aligned with different seismic performance targets. These factors were established through extensive parametric studies. These studies used a simple evaluation structure with a single-bay rectangular diaphragm. The simple evaluation structure is suitable for establishment of the design factors over comprehensive structural geometry and design parameters. However, the application of the design factors to prototype structures with realistic layouts requires further verification and investigation. This paper presents diaphragm design of several precast concrete parking structures using the new design methodology and verification of the design factor through nonlinear dynamic time history analyses. The seismic behavior and performance of the diaphragm were investigated for the precast concrete parking structures. It was found that the design factor established for the new design methodology is applicable to the realistic precast concrete parking structures.

Development of Computational Tools for Seismic Design of Architectural Components in Negative Pressure Isolation Wards (음압격리병동의 건축 비구조요소 내진설계를 위한 전산도구 개발)

  • Chu, Yu Rim;Kim, Tae Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.127-136
    • /
    • 2022
  • Recently, an unprecedented emerging infectious disease has rapidly spread, causing a global shortage of wards. Although various temporary beds have appeared, the supply of wards specializing in infectious diseases is required. Negative pressure isolation wards should maintain their function even after an earthquake. However, the current seismic design standards do not guarantee the negative pressure isolation wards' operational (OP) performance level. For this reason, some are not included in the design target even though they are non-structural elements that require seismic design. Also, the details of non-structural elements are usually determined during the construction phase. It is often necessary to complete the stability review and reinforcement design for non-structural elements within a short period. Against this background, enhanced performance objectives were set to guarantee the OP non-structural performance level, and a computerized tool was developed to quickly perform the seismic design of non-structural elements in the negative pressure isolation wards. This study created a spreadsheet-based computer tool that reflects the components, installation spacing, and design procedures of non-structural elements. Seismic performance review and design of the example non-structural elements were conducted using the computerized tool. The strength of some components was not sufficient, and it was reinforced. As a result, the time and effort required for strength evaluation, displacement evaluation, and reinforcement design were reduced through computerized tools.

Optimal PI Controller Design for Refrigeration System Considering Disturbance (외란을 고려한 냉동시스템의 최적 PI 제어기 설계)

  • Jeong, Seok-Kwon;Hong, Ki-Hak
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.85-93
    • /
    • 2013
  • The proportional plus integral(PI) feedback control manner has been used in many general industrial fields such as refrigeration system because of its simple design process and favorable control performance. This paper deals with optimized PI controller design of the refrigeration system based on evaluation functions such as integrated absolute error(IAE). The suggested optimal PI gains can be easily calculated by a simple program and the optimal controllability satisfying the evaluation function can be assured. Furthermore, at the initial step of controller design, the suggested optimal gain is able to reflect some noise disturbances caused by an inverter which drives variable speed compressors. The validity of the suggested optimal gain is investigated by some simulations and experiments to verify its efficiency. From the results of comparing control performance between the optimal PI controller based on the evaluation function and the PI controller designed by the Matlab tuner which was known as the most popular gain tuner, the optimal PI controller showed more desirable control performance especially in transient responses.

Development of Rolling Type Light-Shelf with Adjustable Reflectivity (반사율 변경이 가능한 롤링타입형 광선반 개발)

  • Kim, Kyungsoo;Shim, Hyungjun;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose: Recently, lighting energy consumption in buildings has been gradually increasing and more studies are being carried out in order to solve this problem. Especially, the efficiency of the light-shelf system, which is a natural lighting system, has been recognized as a potential solution in addressing this problem and so various studies regarding the light-shelf system are being conducted. However, if high luminance material is used for the light-shelf system, glaring may occur in certain circumstances even though such material increases efficiency, and there are also difficulties related to maintenance and management in the case of an external light-shelf system. Therefore, the purpose of this study is to suggest modifications in relation to the reflectivity of the light-shelf system and introduce a rolling type light-shelf system with built-in cleaning equipment. In addition, a performance evaluation technique was established to verify its effectiveness. Method: In this study, we reviewed previous studies related to the light-shelf system and its performance. Then a testbed was established to assess the performance of the rolling-type light-shelf system suggested in this study. Also, the performance of the rolling-type light-shelf system suggested in this study was compared and analyzed with that of existent light-shelf systems in order to better verify the performance, and the uniformity ratio of illumination and lighting energy consumption were calculated for this purpose. Result: The results of the performance evaluation are as follows. 1) The performance evaluation result of the light-shelf system on the day of the summer solstice shows that $30^{\circ}$ is appropriate for the angle of light-shelf system, and the depth of the incoming natural light also increases as the angle of the light shelf increases. 2) It is possible to improve the uniformity ratio of illumination by increasing the reflectivity of the light shelf, and the reason for this is the increase in the amount of incoming light entering indoors due to the increased reflectivity of the light shelf. 3) The rolling type light-shelf system suggested in this study enables energy saving in comparison with existent light-shelf systems, and when the external illuminance decreases to 60,000 lx and 40,000 lx during the summer solstice due to factors such as the weather, the suggested light-shelf system can save energy by 12.1% and 5.1% respectively. Thus the light-shelf system proposed in this study is deemed to be effective in reducing energy costs.

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.