• Title/Summary/Keyword: per-cooling

Search Result 248, Processing Time 0.027 seconds

Characteristic Analysis of Double Effect Absorption Refrigeration Machine using $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ ($H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$를 이용한 2중 효용 흡수식 냉동기 특성해석)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.792-799
    • /
    • 1998
  • Further improvement of existing $H_{2}O/LiBr$ absorption refrigeration machine is absolutely neces-sary to promote the utilization of gas-cooling system Among various methods to improve the per-formance of the absorption refrigeration machine this research has focused on the use of a new working fluid that has better properties than the existing $H_{2}O/LiBr$ working fluid. In the series of the research, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ system was selected as the most promisable candidate. The absorption refrigeration machine is water-cooled double-effect, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ sys-tem with series flow type. In this study we found out the characteristic of new working solution through the cycle simulation and compared the result with that of LiBr solution to evaluate. Theoptimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance. Results demonstrate that new working fluid subsrantially increases COP by as much as 10% and has a wider working range with 8% higher crystallization limits compared to the conventional $H_{2}O/LiBr$.

  • PDF

A Study on the High Efficiency Ground Source Heat Pump System (1) (부하추종형 고효율 지열히트펌프 시스템에 관한 연구 (1))

  • Koh, Deuk-Yong;Kim, Ook-Joong;Choi, Sang-Kyu;Chang, Ki-Chang
    • New & Renewable Energy
    • /
    • v.1 no.4 s.4
    • /
    • pp.30-37
    • /
    • 2005
  • Cycle simulation of Ground Source Heat Pump[GSHP] system was carried out to determine the design specification of basic components such as turbo compressor and heat exchangers. Part load operation characteristics of the designed GSHP system was estimated using the compressor and heat exchanger performance data. A 50RT class turbo compressor for GSHP system is now under development, in which R134a refrigerant is adopted as working fluid. The compressor with variable cascade diffusers is designed to work both in cooling and heating modes so that it can actively keep up with the climate change with high efficiency. The normal running speeds of the compressor are 59000rpm for heating mode and 70000rpm for tooling mode respectively. It has two identical impellers at both ends of the rotor so as to minimize aero-induced thrust force effectively. GSHP system was coupled with a vortical type heat exchanger, and heat gain and heat loss from ground were evaluated per a bore hole. For the optimal integration of the heat pump system, its header for circulating fluid was combined with the ground heat exchangers in parallel and series configuration.

  • PDF

A Study on the Improvement of the Water System in Domestic Boiler (가정용 보일러의 급탕시설 개선방안에 관한 연구)

  • Han, Gyu-Il;Park, Jong-Un
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.200-211
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

Sustained Nuclear Star Formation and the Growth of a Nuclear Bulge

  • Kim, Sung-Soo S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.142.2-142.2
    • /
    • 2011
  • Hydrodynamic simulations of gas clouds in the central hundred parsecs region of the Milky Way that is modeled with a three-dimensional bar potential are presented. Our simulations consider realistic gas cooling and heating, star formation, and supernova feedback. A ring of dense gas clouds forms as a result of $X_1-X_2$ orbit transfer, and our potential model results in a ring radius of ~200 pc, which coincides with the extraordinary reservoir of dense molecular clouds in the inner bulge, the Central Molecular Zone (CMZ). The gas clouds accumulated in the CMZ can reach high enough densities to form stars, and with an appropriate choice of simulation parameters, we successfully reproduce the observed gas mass and the star formation rate (SFR) in the CMZ, ${\sim}2{\times}10^7\;M_{\odot}$ and ${\sim}0.1\;M_{\odot}/yr$. Star formation in our simulations takes place mostly in the outermost $X_2$ orbits, and the SFR per unit surface area outside the CMZ is much lower. These facts suggest that the inner Galactic bulge may harbor a mild version of the nuclear star-forming rings seen in some external disk galaxies. We also find that the stellar population resulting from sustained star formation in the CMZ would be enlogated perpendicularly to the main bar, and this "inner bar" can migrate the gas in the CMZ further down to the central parsecs region.

  • PDF

Effect of Tai Chi Exercise Program on Anxiety, Powerlessness, and Self-esteem in Elderly Women (타이치운동이 여성노인의 불안, 무력감 및 자아존중감에 미치는 효과)

  • Park, Young-Ju;Kim, Mi-Sun
    • Journal of muscle and joint health
    • /
    • v.18 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The purpose of this study was to determine the effect of Tai Chi exercise program (Sun style 12 forms) on anxiety, powerlessness, self-esteem in community-dwelling elderly women. Methods: With a quasi-experimental design, a nonequivalent control group pretest-post test was used. Elderly women who agreed to participate in the study were assigned into an experimental group (n=23), or a control group (n=23). The experimental group participated in Tai Chi exercise program for 50 minutes per session, 2 times a week for 11 weeks. Tai Chi exercise program consisted of 10 minutes for warm-up, 35 minutes for main session, and 5 minutes for cooling down exercises. Anxiety, powerlessness, and self-esteem were measured with questionnaires to evaluate the effect of Tai Chi exercise program. The data were analyzed by using Chi-square test, Fisher's exact test, and Mann-Whitney test by a SPSS WIN 12.0 program. Results: The experimental group showed significant improvement for self-esteem (z=-3.130, p=.002), powerlessness(z=-3.267, p=.001), and anxiety (z=-2.932, p=.003) when compared to control group, Conclusions: Tai chi exercise program may be an effective nursing intervention to improve self-esteem and to reduce powerlessness and anxiety in community-dwelling elderly women.

Hydrox Generator for Steel Manufacturing (철강재료 가공용 수산소 혼합가스 발생기)

  • Kim, Hong-Gun;Kwac, Lee-Ku;Lee, Woo-Gum;Cha, Hwa-Dong;Shin, Jooung-Dal
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.257-262
    • /
    • 2011
  • A low capacity generator converted to high capacity of 40m3 is designed and developed in order to use the hydroxy gas in the steel manufacturing process. For efficient design, it is increased from 8 electrode tubes to 10 electrode tubes as well as expanding the diameter of cell integument up to two times bigger, which can increase the amount of hydrogen occurrence per a cell significantly. In addition, circulating pump and pipe, heat exchanger of affiliated SUS material have been used in the circulation of electrolysis catalyst, and circulating cooling section and piping design are also developed. The flame trap is designed into all-in-one suitable check valve in the flow rate of 28-35m3/h and its application is possibly applied in work operation. It is found that the efficiency of generator developed is enhanced substantially up to 84%. It is expected that the application in this field can be expanded significantly by this study.

Effect of Tai Chi Exercise on Loneliness, Sleep Pattern, and Instrumental Activities of Daily Living in Elderly Women (타이치 운동이 노인의 외로움, 수면양상 및 일상생활수행능력에 미치는 효과)

  • Park, Young-Ju;Park, In-Hyae
    • Journal of muscle and joint health
    • /
    • v.17 no.2
    • /
    • pp.151-161
    • /
    • 2010
  • Purpose: The purpose of this study was to identify the effect of Tai Chi exercise on loneliness, sleep pattern, and instrumental activities of daily living in elderly women. Methods: A quasi-experimental design, a nonequivalent control group pretest-posttest was used. Elderly women who agreed to participated in the study were assigned into an experimental group (n=20) or a control group (n=20). The experimental group participated in Tai Chi exercise program (Sun-style 12 forms) for 50 minutes per session, 2 times a week for 8 weeks. Tai Chi exercise program consisted of 10 minutes for warm-up, 35 minutes for main session, and 5 minutes for cooling down. Study outcomes were measured through study questionnaires. Data were analyzed using Chi-square test, t-test and Mann-Whitney test by SPSS WIN 14.0 program. Results: Compared with the control group, the experimental group showed significant improvement in loneliness (t=-2.733, p=.009), sleep pattern (t=2.552, p=.015), and instrumental activities of daily living (z=-2.171, p=.030). Conclusion: Tai Chi exercise program may be an effective nursing intervention for elderly women.

Effect of Tai Chi Exercise on Fatigue, Anxiety, and Sleep Patterns in Nursing Students (타이치 운동이 간호대학생의 피로, 불안 및 수면양상에 미치는 효과)

  • Park, Young Ju;Kim, Ja Ok
    • Journal of muscle and joint health
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the effect of the Tai Chi exercise program (Sun style 31 forms) on fatigue, anxiety, and sleep patterns in nursing students. Methods: A quasi-experimental study with a non-equivalent control group pretest-posttest design was used. Nursing students who participated in this study were assigned to an experimental group (n=24), and a control group (n=26). The experimental group participated in Tai Chi exercise program for 60 minutes per session, and 3 times a week for 7 weeks. The Tai Chi exercise program consisted of 10 minutes for warm-up, 45 minutes for main session, and 5 minutes for cooling down exercises. The data were collected prior and after the intervention using self-administered questionnaires. Data were analyzed using descriptive statistics, $x^2$-test, Fisher's exact probability, t -test, and the general linear model. Results: After the application of the program, the experimental group showed a significant difference in fatigue (F=20.62, p<.001), anxiety (F=16.96, p<.001), and sleep pattern (F=15.70, p<.001) scores. Conclusion: These findings show that the Tai Chi exercise program can be an effective nursing intervention to improve sleep pattern and to reduce fatigue and anxiety in nursing students.

An Experimental Study on Residential Moving and Satisfaction Causes in Ulsan city (울산시 거주자의 주거이동동기와 주거만족에 관한 연구)

  • 김선중;강혜경
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.249-254
    • /
    • 2002
  • The purpose of this study is to identify the causes-effects of residential mobility and satisfaction. The research design employes a survey questionnaire for gathering a set of statistically-reasonable number of data among one million population of Ulsan metropolitan city. To make it more concrete, the attentions to be taken are on establishing (1) motives for moving (2) satisfaction factors in living, and (3) a relationship between houses and their environmental characteristics and the degree of satisfactions by them. The results of empirical analyses provide the following major findings: The most significant house-moving motivations were to achieve living-space at an affordable size or as wide as possible and to gain access to a comfortable and convenient environment. Per the residential satisfaction, highly respected factors were having good neighbors and active interactions with them and having good cooling-heating conditions, sunny rooms, and less noise and air pollution. Finally, the relation of house and its environment with the satisfaction indicated the following significant two: The higher the satisfaction, the shorter the duration of living and the history of construction. The less the satisfaction, the smaller the size of house and/or its complex.

  • PDF