• Title/Summary/Keyword: per-cooling

Search Result 249, Processing Time 0.029 seconds

Investigation on Performance Characteristics of IPM for Electric Vehicles Considering Driving Conditions and Pole-Slot Combinations

  • Seo, Jangho
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.268-275
    • /
    • 2013
  • This paper shows the characteristics of performance for interior permanent magnet machine (IPM) considering driving conditions such as maximum torque per ampere (MTPA) and flux-weakening control especially in terms of harmonic loss. In particular, based on finite element analysis (FEA), permanent magnet (PM) eddycurrent loss and the harmonic iron loss have been computed where the models have been intentionally designed to identify the effects of pole-slot combinations on the loss while maintaining the required power for electric vehicle. From the analysis results, it was shown that the rotor iron loss and PM eddy-current loss of machine employing fractional slot winding are extremely large at load condition. Furthermore, it was revealed that the harmonic iron loss at high-speed operation is mainly distributed over stator teeth and rotor surface, which may aggravate cooling system of the rotor structure in the vehicle.

A Study on Standard Heating and Cooling Load according to Design Factors using Prototypical Load Model (표준부하모델을 이용한 설계 변수에 따른 표준부하량 분석)

  • Kim, Kwonye;Bae, Sangmu;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Before newly-built building and building remodeling, it is important to predict and analyze building energy performance through energy simulation programs. Nevertheless, simulation results widely vary depending on individual user experience and input values. Therefore, this study uses prototypical building model, a versatile tool in building energy modeling, simulation and research for researchers and policy-makers, and ASHRAE standards. Then, it analyzed the changes in design type (roof type, number of floors) for the base case. As the result, it was found that the gap of annual energy demand per between them is maximally 9.1%.

Analysis on Green BIM based Atrium Sizes in the Early Design Stage (Green BIM기반 초기설계 단계에서 타입별 아트리움의 규모산정에 관한 연구)

  • Jeong, Seung-Woo;Lee, Kweon-Hyoung;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.1
    • /
    • pp.58-70
    • /
    • 2013
  • This study for establishing specific standards of atrium design aims to discuss design of atrium to consider energy performance atrium in office buildings. In order to evaluate a type and a scale of atrium at the early design stage, modeling details of mass design were set as standards of conceptual design. In the experiment, Project Vasari was used to analyze modeling and energy consumption, based on the LOD 100-step suggested by AIA, because there is no guideline to specify a level of modeling details at each design process. From this analysis, the correlation among a simple-typed atrium and scale and energy load was considered. The result of this research is as follows: First, the single-sided atrium reduced energy the most, and it was followed by three-sided, two-sided, four-sided and continuous-typed ones. On the whole, they could decrease energy by up to about 15%. Also, the atrium with a wide facade facing in the south was more favorable to reduce energy. Second, planning the atrium within 10~30% of the whole building area was more energy efficient. Third, rather than the depth, adjusting the length in designing an atrium could reduce cooling and heating loads by 1.5% per 1m. As explained above, energy performance evaluation considering types and planning elements of atrium helps to assess alternatives in a reasonable way. In particular, considering the use of building needs to be preceded to select a type of atrium, although it is also important to consider its planning elements.

Applied cases of advanced construction & engineering technology at Tower Palace III Project (타워팰리스 III 현장의 첨단 시공 및 엔지니어링 기술 적용사례)

  • Wang In-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.202-213
    • /
    • 2003
  • Tower Palace III project is the highest residential and commercial high-rise complex building in Korea. In order to construct a high-rise building, advanced construction and engineering technology is required. Therefore, with more developed construction and engineering technology based upon accumulated knowledge, construction speed of 13.4 days per floor including finish work was achieved in this project. To achieve this project successfully, three main advanced construction technology were applied: 1) Construction methods for 3-day cycle of structural work and curtain wall, 2) Tact scheduling method for finish work, 3) Management system of material, labor, work, and information. Also, four main engineering technology were applied: 1) New material such as high -flowing concrete and high strength concrete of 800 kgf/cm2, 2) New method such as a pipe-cooling system of a cool water circulating type, 3) Mechanical system such as smart-fan controlling kitchen-ventilation system, 4) Electrical system such as false car system.

  • PDF

Design and Analysis of Heat Exchanger Using Sea Water Heat Source for Cooling

  • Kim, MyungRae;Lee, JuHee;Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.25-34
    • /
    • 2016
  • Purpose: The temperature in Seoul has risen 3 times more than the average global temperature increase for the past 100 years. Today, summer starts 15 days earlier than the early 20th century and is 32 days longer. This tendency causes rapid increase of cooling energy demand. Following this effect, seawater heat resources are to be used as an countermeasure for global warming. Incheon Port near the Western Sea has the lowest water temperature in the winter in South Korea in which it is suitable to use seawater cold heat resources. Method: The cold heat resource is gained from seawater when the water temperature is the lowest in the winter time and saved in a seasonal thermal storage. This can be used as cold heat resource in the summer time. A heat exchanger is essential to gain seawater cold energy. Due to this necessity, sea water heat resource heat exchangers are modeled by heat transfer equations and the fluid characteristics are analyzed. Also, a CFD (computational fluid dynamics) program is used to conduct simulation on the fluid characteristics of heat exchangers. The analyzed data of deducted from this process are comprehensively analyzed and discussed. Result: Regarding the performance of the heat exchanger, the heat exchanger was operated following the prediction within the range of heat transfer rate of minimum 3.3KW to maximum 33.6KW per device. In the temperature change analysis of the heat exchanger, fluid analysis by heat transfer equations almost corresponded to the temperature change by CFD simulation. Therefore, it is considered that the results of this study can be used as design data of heat exchangers.

Analysis on Fluid Dynamics in the Cooling Tube for Manufacture of Liquid Hydrogen (액체수소 제조를 위한 냉각튜브 내 유동장 해석)

  • LEE, DAE-WON;NGUYEN, HOANG HAI;NASONOVA, ANNA;OH, IN-HWAN;KIM, KYO-SEON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.301-307
    • /
    • 2015
  • We present a study of hydrogen liquefaction using the CFD (Computational Fluid Dynamics) program. Liquid hydrogen has been evaluated as the best storage method because of high energy per unit mass than gas hydrogen, but efficient hydrogen liquefaction and storage are needed in order to apply actual industrial. In this study, we use the CFD program that apply navier-stokes equation. A hydrogen is cooled by heat transfer with the while passing gas hydrogen through Cu tube. We change diameter and flow rate and observe a change of the temperature and flow rate of gas hydrogen passing through Cu tube. As a result of, less flow rate and larger diameter are confirmed that liquefaction is more well. Ultimately, When we simulate the hydrogen liquefaction by using CFD program, and find optimum results, it is expected to contribute to the more effective and economical aspects such as time and cost.

A Stress Analysis for Pressure Vessel to Prevent Spontaneous Ignition of Coal Stockpile (저탄장 자연발화 방지를 위한 압력용기의 응력 해석)

  • Kim, Young In;Kim, Seung Hun;Jie, Min-Seok;Yeum, Chan Sub;Choi, Won Hyuck
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.3
    • /
    • pp.205-212
    • /
    • 2018
  • Spontaneous ignition is not only severe economic damage but also a typical plant damage caused by harmful gases generated during the fire. Because coal is porous, it causes oxygen to be absorbed in the amount of oxygen per unit weight of oxygen, resulting in low humidity and low thermal conductivity. The cause and effect of spontaneous ignition are very complex, so it is difficult to prevent it beforehand and once it is difficult to digest it, it is difficult to digest it. This study examines structural safety by conducting a structural analysis of the cooling ball system to prevent spontaneous combustion of coal stockpile plants and external pressures.

Integrity Evaluation By IRT Technique And FEM Analysis of Spur Gear (스퍼 기어의 FEM 해석 및 IRT 기법을 적용한 건전성 평가)

  • Roh, Chi-Sung;Jung, Yoon-soo;Lee, Gyung-Il;Kim, Jae-Yeol
    • Tribology and Lubricants
    • /
    • v.32 no.4
    • /
    • pp.113-118
    • /
    • 2016
  • As an economic, high quality, and highly reliable gear with low noise and low vibration is demanded, an overall finite element analysis regarding a gear is required. Also, an infrared thermography test, which is a quantitative testing technique, is demanded for safety and longer lifespan of gear products. In order to manufacture a gear product or to determine safety of a gear being used, it is necessary to precisely determine ingredients of a material constituting a gear and detect any internal defect. This study aims to realize a design that minimizes the spur gear displacement with respect to power during its rotation and ensures the spur gear control capacity by using a 3D model and the midasNFX program. This facilitates the assessment of the possibility of cracking by evaluating the stress intensity and focusing on the integrity of the spur gear. We prepare the specimen of the spur gear based on the possibility of cranking as per the result of the structural interpretation from an infrared ray thermal measuring technique. After cooling the spur gear, we perform experiments using thermography and halogen lamps and analyze the temperature data according to the results of the experiment. In the experiment which we use thermography after cooling, we find a rise in the temperature of the room. As a result, the defective part show temperatures lower than their surroundings while the normal parts have temperatures higher than the defective parts. Therefore, it possible to precisely identify defective part owing to its low temperature.

Design of Thermodynamic Cycle and Cryogenic Turbo Expander for 2 kW Class Brayton Refrigerator (2 kW급 브레이튼 냉동기용 열역학 사이클 및 극저온 터보 팽창기 설계)

  • Lee, Jinwoo;Lee, Changhyeong;Yang, Hyeongseok;Kim, Seokho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.299-305
    • /
    • 2016
  • The High Temperature Superconducting power cables (HTS power cables) become increasingly longer to commercialize the HTS power cable system. Accordingly, demands on refrigerators of large cooling capacity per a unit system have been increased. In Korea, it is currently imported from abroad with the high price due to insufficient domestic technologies. In order to commercialize the HTS power cables, it is necessary to develop the refrigerators with large cooling capacity. The Brayton refrigerators are composed of recuperative heat exchangers, compressors and cryogenic turbo expanders. The most directly considering the efficiency of the Brayton refrigerator, it depends on performance of the cryogenic turbo expander. Rotating at high speed in cryogenic temperature, the cryogenic turbo expanders lower temperature by expanding high pressure of a helium or neon gas. In this paper, the reverse Brayton cycle is designed and the cryogenic turbo expander is designed in accordance with the thermodynamic cycle.

Observation and Analysis of Long and Short-wave Radiation According to Types of Summer Shelters (하계 그늘쉼터 유형별 장·단파복사 관측과 해석)

  • Baek, Chang-Hyeon;Choi, Dong-Ho;Lee, Bu-Yong;Lee, In-Gyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.127-135
    • /
    • 2019
  • In this study, we analyzed the relationship between five factors: long-wave radiation, short-wave radiation, cloudiness, SVF and summer shelters. In the previous study, we recognized the correlation between single building SVF and long-wave radiation. Furthermore, this study attempted to confirm the relationship at the summer shelter with high solar radiation blocking rate. The observations are as follows. ① Cooling in summer shelters was not the effect of temperature but the effect of radiation reduction due to short-wave radiation shielding. ② In the case of the canopy tent with low heat capacity, the long-wave radiation was observed to be 16.7% higher per hour than the comparison control point due to the increase in surface temperature. ③ The long-wave radiation increase rate was different according to SVF, but showed very similar pattern according to the material characteristics of the summer shelters. ④ Passive Cooling effect on the type of summer shelters are determined by the size of the total long and short-wave radiation at that point.