Chloride Ion Penetration Resistance of Mortars including Expanded Vermiculite Immobilizing Bacteria (박테리아 흡착 팽창질석을 혼입한 모르타르의 염소이온 침투 저항성)

  • Jung, Seung-Bae;Yang, Keun-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.151-152
    • /
    • 2017
  • This tests examined the effectiveness of bacteria slime on the chloride ion penetration resistance of cement mortar. Test results exhibited that the chloride ion penetration depth of mortars including 5% expanded vermiculite immobilizing bacteria was 17% smaller than that of the control mortar without expanded vermiculite.

  • PDF

A Study on the ballistic performance and fracture mode of anodized Aluminum 5052-H34 alloy laminates (알루미늄 5052-H34 합금 적층재의 방탄성능과 파괴모드에 관한 연구)

  • 손세원;김희재;박영의;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.507-512
    • /
    • 2000
  • The ob.jective of this study is to determine fracture behaviors(penetrati0n modes) and resistance to penetration duringballistic impact of Al 5052-H34 alloy laminates and anodized Al 5052-H34 alloy laminates. Resistance to penetration is determined by $V_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed that result from V50 test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with 0" obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ tests with 0" obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface Hardness, resistance to penetration, and penetration modes of A1 5052-H34 alloy laminates compared to those of anodized Al 5052-H34 alloy laminates.y laminates.

  • PDF

An Experimental Study on the Impact Characteristics of Surface Hardened Al 5052-H34 Alloy (표면처리된 알루미늄 5052-H34 합금의 층격특성에 관한 실험적 연구)

  • 손세원;김희재;이두성;홍성희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.178-186
    • /
    • 2003
  • In order to investigate the fracture behaviors (penetration modes) and the resistance to penetration during ballistic impact of Al 5052-H34 alloy laminates, cold-rolled Al 5052-H34 alloy laminates, anodized Al 5052-H34 alloy laminates, and anodized Al 5052-H34 alloy after cold-rolling, a ballistic testing was conducted. In general, superior armor materials are brittle materials which have a high hardness. Ballistic resistance of these materials was measured by a protection ballistic limit (V$_{50}$), a statistical velocity with 50% probability fur incompletete penetration. Fracture begaviors and ballistic tolerance, described by penetration modes, ate observed from the results from the results of V$_{50}$ test and Projectile Through Plates (PTP) test at velocities greater than V$_{50}$, respectively. PTP tests were conducted with 0$_{\circ}$obliquity at room temperature using 5.56mm ball projectile. V$_{50}$ tests with 0$_{\circ}$obliquity at room temperature were concucted with projectiles that could achieve neat or complete penetration during PTP tests. Surface hardness, resistance to penetration, and penetration modes of Al 5052-H34 alloy laminates are compared to those of cold-rolled Al 5052-H34 alloy laminates and anodized Al 5052-H34 alloy laminates and anodized Al 5052-H34 cold-rolled alloy.

A study on the fracture behavior of Ti/Al laminates under high velocity impact (고속충격을 받는 Ti/Al 적층재의 파괴거동에 관한 연구)

  • Sohn, Se-Won;Lee, Doo-Sung;Hong, Sung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.267-272
    • /
    • 2003
  • In order to investigate the effect of face material on Ti/Al alloy laminates under high velocity impact, a ballistic testing was conducted. Ballistic resistance of these materials was measured by protection ballistic limit($V_{50}$), a statistical velocity with 50% probability penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, were respectfully observed, by $V_{50}$ test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with $0^{\circ}$obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ tests with $0^{\circ}$obliquity were also done with projectiles that were able to achieve near or complete penetration during PTP tests. Resistance to penetration, and penetration modes which face material was Titanium alloy, were compared to those which face material was anodized Al alloy after cold-rolling.

  • PDF

The Perforation Behavior of the Anodized AI Light Armor under High Velocity Impact

  • Sohn, Se-Won;Lee, Doo-Sung;Kim, Hee-Jae;Hong, Sung-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.4
    • /
    • pp.45-50
    • /
    • 2003
  • In order to investigate the effect of surface treatment (Anodizing) and rolling on AI 5083-H131 alloy, under hyper velocity impact, a ballistic testing was conducted. Ballistic resistance of these materials was measured by a protection ballistic limit ($V_{50}$)' a statistical velocity with 50% probability of penetration. Perforation behavior and ballistic tolerance, described by penetration modes, were respectfully observed, by $V_{50}$ test and Projectile Through Plates (PTP) test at velocities greater than $V_{50}$. PTP tests were conducted with 0$^{\circ}$ obliquity at room temperature using 5.56mm ball projectiles. $V_{50}$ tests with 0$^{\circ}$ obliquity were also done with projectiles that were able to achieve near or complete penetration during PTP tests. Resistance to penetration, and penetration modes of Al 5052-H34 alloy were compared to those of Al 5083-H 131 alloy.

Evaluation on Resistance of Chloride Attack and Freezing and Thawing of Concrete with Surface Penetration Sealer (표면 침투제에 따른 콘크리트의 염화물 침투와 동결융해 저항성 평가)

  • Kim Myung Yu;Yang Eun Ik;Lho Byeong Cheol;Kim Jeong Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.505-508
    • /
    • 2005
  • Concrete has a void, which exists as one of defect in concrete. If the porosity of concrete increases, durability of concrete decreases. In this paper, to improve surface void of concrete, surface penetration sealers are applied to specimen. And it were investigated that the resistances of chloride penetration and freezing and thawing for concrete with surface penetration sealer of two types. According to the results, surface penetration sealer has not show a harmful influence on strength and resistance of freezing and thawing. Also, B type surface penetration sealer was more superior in resistance of chloride penetration.

  • PDF

Study on the Measurement of Liquid Limit Using a Penetration Resistance of Small Cone in Clay Soil (소형콘의 관입저항력을 이용한 점토의 액성한계측정에 관한 연구)

  • Son, Moorak;Lee, Jaeyong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.5-15
    • /
    • 2016
  • This study investigated both water content and penetration resistance of small cone of various clay soils that were made of Kaolinite and Bentonite with different mixing ratios and compared the results with those of the existing dynamic (Casagrande test) and static (fall cone test) tests directly. The comparison showed that the water content at the inflection point on a curve of water content and penetration resistance was very similar to the liquid limit from a fall cone test. The penetration resistance of small cone at the inflection point was 0.2 kPa, and it was ascertained that the water content at the inflection point represents a liquid limit of clay soils. From the study results, it was found that the penetration resistance of 0.2 kPa with the small cone can be an indicator of the liquid limit of clay soils in practice. Finally a test procedure to measure the liquid limit of clay soil based on a penetration resistance of small cone was proposed.

A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs (옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Sun, Yoon-Suk;Kwon, Shi-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

A Study on the Chemical Resistance Improvement of Concrete Applied by Surface Penetration Sealers (표면침투제를 적용한 콘크리트의 내화학성 개선에 관한 연구)

  • Lho, Byeong-Cheol;Choi, Kyu-Hyung;Kim, Jeong-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.567-570
    • /
    • 2005
  • This study aims to verify the relationship between the penetration depth and chemical resistance, which can demonstrates the performance of the applied surface penetration sealers.