• Title/Summary/Keyword: penetration energy

Search Result 636, Processing Time 0.028 seconds

Estimation of Groundwater Table using Ground Penetration Radar (GPR) in a Sand Tank Model and at an Alluvial Field Site (실내 모형과 현장 충적층에서 지하투과레이더를 이용한 지하수면 추정)

  • Kim, Byung-Woo;Kim, Hyoung-Soo;Choi, Doo-Houng;Koh, Yong-Kwon
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.201-216
    • /
    • 2013
  • Ground penetrating radar (GPR) surveys were conducted in a sand tank model in a laboratory and at an alluvial field site to detect the groundwater table and to investigate the influence of saturation on GPR response in the unsaturated zone. In the sand tank model, the groundwater table and saturation in the sand layer were altered by injecting water, which was then drained by a valve inserted into the bottom of the tank. GPR vertical reflection profile (VRP) data were obtained in the sand tank model for rising and lowering of the groundwater table to estimate the groundwater table and saturation. Results of the lab-scale model provide information on the sensitivity of GPR signals to changes in the water content and in the groundwater table. GPR wave velocities in the vadose zone are controlled mainly by variations in water content (increased travel time is interpreted as an increase in saturation). At the field site, VRP data were collected to a depth of 220 m to estimate the groundwater table at an alluvial site near the Nakdong river at Iryong-ri, Haman-gun, South Korea. Results of the field survey indicate that under saturated conditions, the first reflector of the GPR is indicative of the capillary fringe and not the actual groundwater table. To measure the groundwater table more accurately, we performed a GPR survey using the common mid-point (CMP) method in the vicinity of well-3, and sunk a well to check the groundwater table. The resultant CMP data revealed reflective events from the capillary fringe and groundwater table showing hyperbolic patterns. The normal moveout correction was applied to evaluate the velocity of the GPR, which improved the accuracy of saturation and groundwater table information at depth. The GPR results show that the saturation information, including the groundwater table, is useful in assessing the hydrogeologic properties of the vadose zone in the field.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

Design Development Test of Crashworthiness Device for Landing Gear (착륙장치 내추락 장치 설계개발시험)

  • Shin, Jeong-Woo;Kim, Tae-Uk;Hwang, In-Hee;Jo, Jeong-Jun;Lee, Jeong-Sun;Park, Chong-Yeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.111-116
    • /
    • 2010
  • To improve occupants' safety in an emergency, crashworthy design is necessary to rotorcraft design and development. Especially, landing gear has the important role for crashworthy design because landing gear absorbs relatively large energy for the crash landing. In addition, military specifications require failure of landing gear shall not increase danger to any occupants by penetration of the airframe. To meet the specification requirements, crashworthiness device like failure mechanism should be prepared so that landing gear is collapsed safely and doesn't penetrate the airframe. In this study, design and design development test of the failure mechanism which is necessary for the rotorcraft landing gear was performed. First, collapse scenario was determined for the landing gear not to penetrate the airframe. Then, the failure pin which is the most important part of the failure mechanism was designed with 2 strength range in order to meet design criteria. Finally, design of the failure mechanism was verified successfully by design development test.

Performance estimation depending on the insert size of conical picks by linear cutting test (선형절삭시험에 의한 코니컬커터의 삽입재 크기에 따른 절삭성능 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho;Lee, Cheol-Ho;Lee, Gyu-Phil;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.2
    • /
    • pp.221-233
    • /
    • 2016
  • In order to estimate the performance of a conical cutter depending on the insert size, this study measured forces acting on conical cutters with different cutter spacings, penetration depths and skew angles using slim and heavy conical cutters. When cutter spacings ranged from 12 to 27 mm, the deviations of mean cutter forces with cutter depths appeared smaller compared to other cutter spacings. When skew angle is $0^{\circ}$, the optimal S/d ratio was obtained in the range of 4 to 4.5 for which specific energy of cutting was minimized. It were usually found in the range of 1 to 5. However, when skew angle is $6^{\circ}$, the optimal S/d ratio was obtained in the range of 1 to 3. The simple comparison results shows that the performance of slim cutter was superior to that of heavy cutter, but the use of heavy cutter can be effective, considering the cutter consumption and cutter damage when the strength of the ground is high enough.

A Study of Warm-Mix Asphalt's Bonding Properties on the Change of Asphalt Film Thicknesses (아스팔트 피막두께 변화에 따른 중온 아스팔트의 접착성질에 관한 연구)

  • Yoo, In-Sang;Cho, Dong-Woo;Hwang, Sung-Do;Rhee, Suk-Keun
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.29-40
    • /
    • 2011
  • Warm-Mix Asphalt(WMA) technologies have been developed since 15 years ago, which are internationally and domestically concerned with energy-saving and environmental-friendly technologies in public and private sectors of highway engineering. The performance of asphalt mass is traditionally evaluated by the penetration, viscosity, or Superpave tests. This research, however, is focused more on the properties depending on asphalt film thicknesses instead of evaluating asphalt mass behaviors by those tests. For this approach, a new testing protocol and analysis method are described by the bonding properties on each film thickness. This testing method and analysis tool are borrowed from those of DSR Moisture Damage test and applied by using ARES. The analysis results indicate that there is a limit film thickness between $200{\mu}m$ and $400{\mu}m$, which causes significant changes of the properties. In addition, the results show that the property changes of Hot-Mix Asphalt(HMA) and WMA on the limit film thickness are also different. Therefore, it is suggested that the properties on thin film thicknesses between $200{\mu}m$ and $400{\mu}m$ should be considered in order to evaluate WMA properly.

The Effect of Glass Fabric Separator Elongation on Electric Property in Structural Battery (유리섬유 분리막 인장으로 인한 구조전지의 전기적 물성 변화)

  • Shin, Jae-Sung;Park, Hyun-Wook;Park, Mi-Young;Kim, Chun-Gon;Kim, Soo-Hyun
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.46-51
    • /
    • 2017
  • Structural battery has been researched extensively to combine the functions of the battery and structure without gravimetric or volumetric increments compared to their individual components. The main idea is to employ carbon fabric as the reinforcement and electrode, glass fabric as the separator, and solid-state electrolyte which can transfer load. However, state-of-the-art solid-state electrolytes do not have sufficient load carrying functionality and exhibiting appropriate ion conductivity simultaneously. Therefore, in this research, a system which has both battery and load carrying capabilities using glass fabric separator and liquid electrolyte was devised and tested to investigate the potential and feasibility of this structural battery system and observe electric properties. It was observed that elongating separator decreased electrical behavior stability. A possible cause of this phenomenon was the elongated glass fabric separator inadequately preventing the penetration of small particles of the cathode material into the anode. This problem was verified additionally by using a commercial separator. The characteristic of the glass fabric and the interface between the electrode and glass fabric needed to be further studied for the realization of such a load carrying structural battery system.

Study on the 'Diagnosis and Treatment of the Woman Various Diseases' in Synopsis Golden Chamber (금궤요략${\cdot}$부인잡병맥증병치제이십이(婦人雜病脈證幷治第二十二)에 대(對)한 연구(硏究))

  • Lee, Tae-Ho;Lim, Dong-Kook;Koh, Seung-Wook;Jeong, Heon-Young;Keum, Kyoung-Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.1
    • /
    • pp.32-50
    • /
    • 2008
  • This study is concerned with examining the causes and symptoms of Woman various diseases and clearing up the situations of pulses and their treatment. Woman various diseases are said to be various kinds of diseases including the disorder of menstruation and genitals except pregnancy and postpartum diseases. The main contents are the penetration of heat into worm, the discharge of much blood, stomachache, and the postpartum cyst diseases. Among them, the nature of the diseases which often occur in the gynecology, such as the menstrual diseases and stomachache, were described comparatively in detail. The reason why heat penetrates into the worm is that the external germs come into it under its weakness. To treat it, heat should be removed and lumping blood should be sent out of body. Especially only after whether the disease is serious or not is examined, and just after the process of the disease is examined, the lumping blood can be eliminated. The ways to cure it by sweating a patient too much, getting him or her to vomit, or forcing him or her to be urinated too much, should be avoided. The disorder of menstruation, as the disease which most often occur among the diseases of gynecology, includes menstrual irregularity and blood discharge, and non-menstruation. Among them, non-menstruation and blood discharge are comparatively often discussed. When they are treated, lumping blood and cold energy should be cured well through getting rid of the lumping blood and making the blood vessel flow well. The difficult urination after childbirth, which comes from the weak urinary cist, makes symptoms such as the stuffy chest, the difficulty of lying down, and breathing with his or her back something. To urinate better, the ability of the urinary cist should be supplemented and improved. The principle of the treatment for Woman various diseases is to examine the situation of the pulse closely, then set up the way to treat it, and prescribe a patient. In this study, besides the treatment of Chinese herb medicine, the medicine for washing genitals and the medicine placed in the worm were used to cure Woman various diseases. This treatment is the beginning of the surgical treatment in the gynecology.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

A Study on the Micellization of Sodium Dodecyl Sulfate in 𝜔-Phenylakylammonium Salt Solution (𝜔-Phenylalkylammonium Salt의 수용액에서 Sodium Dodecyl Sulfate의 미셀에 관한 연구)

  • Ryu, Yeanho;Oh, Jung Hee
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.1041-1047
    • /
    • 1997
  • The influence of $\omega$-phenylalkylammonium salt on the critical micelle concentration (CMC) of SDS has been examined using the electric conductivity method. CMC of SDS exhibited the tendency to decrease with the length of alkyl group of additives. The effect of temperature on CMC of SDS in additive solutions has been observed in the range of $18^{\circ}C-50^{\circ}C$. The free energy(${\Delta}G_m^{\circ}$) for the micellization of SDS is negative and the entropy(${\Delta}S_m^{\circ}$) is a large positive value. The enthalpy(ΔHm0is positive in low temperature($18^{\circ}C$) and negative in high temperature($>25^{\circ}C$). In the prensence of organic additives, the micellization of SDS was considered as a spontaneous process and to involve a phase transition. The values of ΔGm0has shown the tendency to increase but the values of ${\Delta}S_m^{\circ}$ and ${\Delta}H_m^{\circ}$ to decrease with the length of alklyl group of additive salts. The changes in ${\Delta}\kappa$(difference of specific conductivity) with increasing mole ratio of additives in the mixed solutions indicated the formation of mixed micelles between SDS and additives. The effect of the length of alkyl chain on the micellization of SDS demonstrated the penetration of organic additives into the palisade layer of the SDS micelle.

  • PDF

A Study on the Stabilization of the Papain Enzyme in the Moderately Concentrated Anionic Surfactant System (음이온 계면활성제에서 파파인 효소의 안정도에 관한 연구)

  • Kim, Ji-Yeong;Kim, Jin-Woo;Kim, Yong-Jin;Lee, Jae-Wook;Lee, Hae-Kwang;Kang, Hak-Hee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.2
    • /
    • pp.93-97
    • /
    • 2007
  • Even in the moderately concentrated anionic surfactant system, some special encapsulation method can shield the papain enzyme from proteolytic attacks. The stabilization of enzyme has been a major issue for successful therapies. In this study, we first stabilized an enzyme, papain in the microcapsules by using polyols, polyethyleneglycol (PEG), poly-propyleneglycol (PPG), and PEG-PPG-PEG block copolymer. In the analysis of EDS and CLSM, it was demonstrated that polyols are effectively located in the interface of papain and polymer. Polyols located in the interface had an ability to buffer the external triggers by hydrophobic partitioning, preventing consequently the catalytic activity of papain in the micro-capsules. Second. we introduced multi-layer capsulation methods containing ion complex. Such a moderately concentrated anionic surfactant system as wash-off cleansers, surfactants and waters can cause instability of entrapped enzymes. Surfactants and water in our final products swell the surface of enzyme capsules and penetrate into the core so easily that we can not achieve the effect of enzyme, papain. In this case, the ion complex multi-layer capsule composed of sodium lauroyl sarcosinate and polyquaternium-6 could effectively prevent water from penetration into the core enzyme, followed by in vivo test, and evaluate the stratum corneum (SC) turn-over speed.