• 제목/요약/키워드: penetrated chlorides

검색결과 10건 처리시간 0.02초

콘크리트의 표면거칠기에 따른 비래염분 침투 특성 (Properties on the penetration of airborne chlorides to the surface roughness of concrete)

  • 이종석;최원성;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.273-276
    • /
    • 2006
  • Airborne chlorides is moved to inland by sea wind and attach to the surface of concrete then penetrated into concrete. In addition, concrete structures are greatly affected by salt attack primarily due to airborne chlorides like it can be seen through the corrosion of rebar. Therefore, it is important to review the relationship among airborne, surface and penetrated chlorides. In this study, airborne, surface and penetrated chlorides were examined in terms of surface roughness of concrete. The results showed that penetrated and surface chlorides have close relationship with surface roughness of concrete.

  • PDF

해안환경에 노출된 콘크리트의 비래염분 침투 특성 (Penetration Properties of Airborne Chlorides on Concrete Exposed in Marine Environment)

  • 이종석;안기홍
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.553-558
    • /
    • 2012
  • 대기 중의 비래염분은 해풍에 의해 내륙으로 이동되고 해안 인근 콘크리트 구조물의 표면에 부착하여 내부로 침투하게 된다. 비래염분 환경에 있는 콘크리트 구조물의 표면염분량은 비래염분량에 의해 영향을 받기 때문에 비래염분량의 분포 특성에 따라 표면염분량도 변화하는 경향이 있다. 따라서, 비래염분 환경 하의 구조물은 해수에 직접접하는 구조물과 달리 표면부의 염분량을 예측하기가 상대적으로 어렵고, 침투되는 경향 또한 다르기 때문에 이에 대한 결과를 얻는것은 중요하다고 할 수 있다. 따라서, 이 연구에서는 비래염분 환경에서 콘크리트 표면으로부터 내부로 침투하는 염분을 표면염분량과 침투 염분량으로 구분하여 그 특성을 파악하였다. 이를 위하여 콘크리트 시험체를 제작하여 해안 현장에서 옥외노출실험을 3년간 실시하였으며, 노출기간 1년과 2년, 3년차에서 시험체를 회수하여 표면염분량 및 표면으로부터 깊이별 비래염분 침투량을 분석하였다. 분석 결과, 콘크리트의 표면조도에 따라 표면염분량의 차이가 발생하였으며, 강우의 영향을 받지 않은 경우 더 많은 표면염분량이 존재하였다. 침투 염분량은 대기중의 비래염분량 및 노출기간에 따라 차이가 발생하였으며, 장기재령으로 갈수록 표면부보다 콘크리트 내부에서 많은 염분량을 나타내는 경향이 두드러졌다.

국도 상 도로시설물 대상 열화환경 조건 별 콘크리트 염화물 침투 특성 분석 (Analysis of Chloride Ion Penetration Properties into Concrete on Road Facilities Depending on the Deterioration Environments)

  • 민지영;이종석;이탁곤;차기혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.102-113
    • /
    • 2021
  • 「시설물의 안전 및 유지관리 실시 세부지침(성능평가편)」의 내구성능 평가에서 열화환경 평가항목으로 제시된 제설제 및 비래염분에 의한 염해환경, 동해환경이 국내 국도 상 콘크리트 도로시설물의 염화물 침투특성에 미치는 영향을 살펴보았다. 강원 고성, 서울, 경기 고양, 부산에 위치한 교량 총 4개소, 강원권 방호울타리 4개소, 부산권 방호울타리 3개소 및 옹벽 1개소를 대상 시설물로 선정하였으며, 제설제에 의한 직접·간접적인 염해환경, 해안거리 및 교각 높이별 비래염분에 의한 염해환경에서 염화물 침투특성을 분석하였다. 분석 결과, (1) 제설제 살포일수(강설일수)에 따른 지역별 특성이 명확하게 구분되었고, (2) 바닥판 관통 누수 혹은 신축이음부를 통한 누수 등이 발생한 경우 침투 염화물량이 유의미한 수준까지 증가하였으며, (3) 부산 해안가에 위치한 교량의 경우 높이 20m까지 비래염분의 영향권에 해당함을 확인하였다. 이로부터, 동일한 시설물이라도 노출된 열화환경, 부재의 위치 및 높이, 열화진전상태에 따라 염화물 침투특성이 달라지기 때문에 시설물 점검 시 점검대상 부재 및 위치의 선정이 매우 중요함을 확인하였으며, 국내 지역별 및 부재별 열화환경에서의 염화물 침투특성에 관한 데이터베이스를 구축한다면 콘크리트 시설물에 대한 선제적인 내구성능 관리가 가능할 것으로 기대된다.

염해 및 황산염의 복합작용에 따른 염소이온 확산특성의 실험적 연구 (Experimental Study of Chlorides Ion Diffusion Characteristics under Combined Condition of Chlorides and Sulfates)

  • 오병환;김선우;정상화;서정문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.413-418
    • /
    • 2000
  • The test results on the deterioration process of concrete under single and combined action of chloride penetration have been obtained. Within the test period of 15 weeks, it is seen that the internally penetrated chloride ion contents are slightly less in the combined action of NaCI and $Na_2SO_4$ than the single action of NaCI. Also the theoretical prediction of chloride penetration based on measured diffusion coefficient agress well with the test data of single deterioration process but disagress with that of combined process. Therefore it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF

고로슬래그미분말 치환 콘크리트의 염화물 침투특성에 관한 연구 (A Study on the Chloride ion Penetration Characteristic of Concrete containing Ground Granulated Blast Furnace Slag)

  • 김현수;지남용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.997-1002
    • /
    • 2001
  • There are two types of chloride in concrete; one is added as concrete materials' chloride when concrete's mixing, and .the other is penetrated from the air and sea water in the sea-shore area. These chlorides penetrate into concrete, and they are accumulated inside the concrete with aging. This study aimed to evaluate the chloride ion penetration resistance of concrete containing GGBFS in the sea-shore area. Therefore, the specimens made with the replacement ratios(0, 0.30, 0.45, 0.60) of GGBFS were put into 3% NaCl solution according to the chloride accelerating test of JCI-SC3, and then investigated the weight changes, compressive strength, chloride ion with the depths of the specimens by aging. The result is that the diffusion coefficient of chloride ion is decreased with the increase of replacement ratios when compared to OPC

  • PDF

염화물 및 황산염 복합환경 하에서의 열화특성에 관한 실험적 연구 (Experimental Study on Deterioration Characteristics under Combined Exposure Conditions of Chlorides and Sulfates)

  • 오병환;인광진;강의영;김지상;서정문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.771-776
    • /
    • 2001
  • Test results on the deterioration process of concrete under single and combined attacks of chloride penetration have been obtained. After test period of 52 weeks, it is found that the internally penetrated chloride ion contents are less in the single attacks of chloride than the combined attacks of chloride and sulfate. Both the diffusion coefficients and surface chloride concentration derived form the chloride profiles showed a time dependence. Also the performance of fly ash-blended cements was observed to be better than plain cements in retarding chloride attack. However it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF

해안매립지에 위치한 전력구 콘크리트 구조물의 내구성 조사 (Investigation of Durability of Electric Power Concrete Structures Exposed to Reclaimed Marine Land)

  • 김성수;박광필;남바름;유주환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.597-600
    • /
    • 2006
  • In Marine Land underground reinforced concrete structures, such as electric box power structure, water and chloride ion penetrated into concrete through the cracks of concrete and its permeable property, cause the corrosion of reinforcing steel bar, which accelerates the expansive cracks and deterioration of concrete. The purpose of this paper is to evaluate on deterioration of durability concrete through instrumental analysis such as schmidt hammer and carbonation, chloride content. Under the reclaimed marine land, the main cause of deterioration of concrete structures is the steel corrosion due to the penetration of chlorides and the deterioration of outer concrete itself by chemical attack.

  • PDF

Chloride penetration in anchorage concrete of suspension bridge during construction stage

  • Yang, In-Hwan;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Advances in concrete construction
    • /
    • 제10권1호
    • /
    • pp.13-20
    • /
    • 2020
  • Steel corrosion in embedded steel causes a significant durability problems and this usually propagates to structural degradation. Large-scaled concrete structures, PSC (Pre-stressed Concrete) or RC (Reinforced Concrete) structures, are usually constructed with mass concrete and require quite a long construction period. When they are located near to sea shore, chloride ion penetrates into concrete through direct or indirect exposure to marine environment, and this leads durability problems. Even if the structures are sheltered from chloride ingress outside after construction, the chloride contents which have been penetrated into concrete during the long construction period are differently evaluated from the initially mixed chloride content. In the study, chloride profiles in cores extracted from anchorage concrete block in two large-scaled suspension bridge (K and P structure) are evaluated considering the exposure periods and conditions. Total 21 cores in tendon room and chamber room were obtained, and the acid-soluble chlorides and compressive strength were evaluated for the structures containing construction period around 3 years. The test results like diffusion coefficient and surface chloride content from the construction joint and cracked area were also discussed with the considerations for maintenance.

이미지 분석을 이용한 균열 콘크리트 내 염화물 침투 정량화 평가 (Quantifying Chloride Ingress in Cracked Concrete Using Image Processing)

  • 김건수;박기태;김재환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.57-64
    • /
    • 2022
  • 염화물은 철근 콘크리트 구조물의 주요 열화 요인 중 하나로 철근 부식을 발생시켜 구조물의 성능을 저하시킨다. 염해에 의한 철근 콘크리트 구조물의 열화정도 또는 철근 부식 개시 시기를 확인하기 위해서는 철근 깊이에서의 염화물 농도 또는 콘크리트 내에서 염화물 침투 속도를 확인할 필요가 있다. 일반적인 콘크리트내 염화물 침투를 확인할 수 있는 방법으로는 염화물 침투 깊이별로 전위차 적정법과 같은 방법으로 염화물 농도를 측정하는 염화물 프로파일링 방법이나 질산은 용액을 이용하여 콘크리트의 변색된 범위를 다지점 측정하여 침투 깊이를 측정하는 방법이 대표적이다. 전자의 경우에는 정확하게 염화물 농도를 직접 측정하기 때문에 염화물 침투 속도 (일반적으로 확산계수)를 정확하게 예측할 수 있는 장점이 있지만, 작업이 번거롭다는 단점이 있다. 후자는 질산은 용액과의 반응에 따른 변색 범위를 측정하여 염화물 침투 깊이를 산정하는 것이기 때문에 간편하고 결과의 신뢰성도 확보할 수 있는 장점이 있지만, 침투 깊이를 산정하는데 있어서 작업자의 숙련도에 따라 오류가 발생할 수 있는 단점이 있다. 본 연구에서는 변색법에 의해 얻어진 결과를 이미지 분석을 통해 콘크리트 내의 염화물 침투 깊이를 분석하였다. 이를 통해 작업자에 의해 발생될 수 있는 오류를 최소화할 수 있도록 하였다. 또한 콘크리트의 미세 균열이 염화물 침투에 미치는 영향에 대해서도 확인하였다. 이미지 분석을 통해 염화물 침투 깊이를 정량화한 결과 염화물은 미세균열부를 통해 빠른 속도로 염화물 침투가 발생한다는 것을 확인 하였기 때문에, 콘크리트 구조물에서는 특히 균열 발생에 주의가 필요할 것으로 판단된다.

Service life evaluation of HPC with increasing surface chlorides from field data in different sea conditions

  • Jong-Suk Lee;Keun-Hyeok Yang;Yong-Sik Yoon;Jin-Won Nam;Seug-Jun Kwon
    • Advances in concrete construction
    • /
    • 제16권3호
    • /
    • pp.155-167
    • /
    • 2023
  • The penetrated chloride in concrete has different behavior with mix proportions and local exposure conditions, even in the same environments, so that it is very important to quantify surface chloride contents for durability design. As well known, the surface chloride content which is a key parameter like external loading in structural safety design increases with exposure period. In this study, concrete samples containing OPC (Ordinary Portland Cement), GGBFS (Ground Granulated Blast Furnace Slag), and FA (Fly Ash) had been exposed to submerged, tidal, and splash area for 5 years, then the surface chloride contents changing with exposure period were evaluated. The surface chloride contents were obtained from the chloride profile based on the Fick's 2nd Law, and the regression analysis for them was performed with exponential and square root function. After exposure period of 5 years in submerged and tidal area conditions, the surface chloride content of OPC concrete increased to 6.4 kg/m3 - 7.3 kg/m3, and the surface chloride content of GGBFS concrete was evaluated as 7.3 kg/m3 - 11.5 kg/m3. In the higher replacement ratio of GGBFS, the higher surface chloride contents were evaluated. The surface chloride content in FA concrete showed a range of 6.7 kg/m3 to 9.9 kg/m3, which was the intermediate level of OPC and GGBFS concrete. In the case of splash area, the surface chloride contents in all specimens were from 0.59 kg/m3 to 0.75 kg/m3, which was the lowest of all exposure conditions. Experimental constants available for durability design of chloride ingress were derived through regression analysis over exposure period. In the concrete with GGBFS replacement ratio of 50%, the increase rate of surface chloride contents decreased rapidly as the water to binder ratio increased.