Purpose : The purpose of this study was to investigate effects of kinesio taping of thigh muscle on isokinetic muscular function during closed kinetic chain exercise of lower extremity. Methods : Twenty healthy males were participated in this study. The isokinetic muscular function of closed kinetic chain were measured for peak torque, peak torque % body weight, average power, max rep tot work before and after application of kinesio taping on thigh muscles. Results : At $60^{\circ}/s$ peak force and peak force % body weight were significant increased in both extension(p<0.01) and flexion(p<0.001) after applying kinesio taping. At $180^{\circ}/s$ average power was significant increased in both extension and flexion after applying taping(p<0.001). At $240^{\circ}/s$ max rep tot work was significant increased in both extension(p<0.001) and flexion(p<0.05). Conclusion : This study suggests that application of kinesio taping on thigh muscle was more effective to improve isokinetic muscular function in closed kinetic chain exercise of lower extremity.
We investigated the biomechanics and characteristics of shoulder rotator muscles for professional woman volleyball players. The purpose of this study was to analyze the isokinetic peak torque and range of motion for shoulder joint rotation. We measured the strength and ROM of the internal rotation(IR) and external rotation(ER) of shoulders joint for nine professional woman Volleyball players and nine University students with Biodex and Simi-motion. 1. We measured peak torques for the shoulder joint rotator at angular velocities of 60/s and 180/s. It was found that the peak torques were significantly different between the two groups and also between the hands used. 2. At angular velocity of 60/s, IR/ER ratio of the shoulder joint was significantly different depending on the groups and the hands in use. There was a significant difference for 'Dominant side' at angular velocity of 180/s, but no significant difference for 'Non-dominant side' and the controls group. 3. Regarding the ROM of rotation of the shoulder joint group, IR was significantly different between the groups and the hands in use. 4. IR/ER ratio of the shoulder joint for Dominant side was quite different between the groups.
International Journal of Fluid Machinery and Systems
/
v.3
no.2
/
pp.113-121
/
2010
LES(Large Eddy Simulation) with a cavitation model was performed to calculate an unsteady flow for a mixed flow pump with a closed type impeller. First, the comparison between the numerical and experimental results was done to evaluate a computational accuracy. Second, the torque acting on the blade was calculated by simulation to investigate how the cavitation caused the fluctuation of torque. The absolute pressure around the leading edge on the suction side of blade surface had positive impulsive peaks in both the numerical and experimental results. The simulation showed that those peaks were caused by the cavitaion which contracted and vanished around the leading edge. The absolute pressure was predicted by simulation with -10% error. The absolute pressure around the trailing edge on the suction side of blade surface had no impulsive peaks in both the numerical and experimental results, because the absolute pressure was 100 times higher than the saturated vapor pressure. The simulation results showed that the cavitation was generated around the throat, then contracted and finally vanished. The simulated pump had five throats and cavitation behaviors such as contraction and vanishing around five throats were different from each other. For instance, the cavitations around those five throats were not vanished at the same time. When the cavitation was contracted and finally vanished, the absolute pressure on the blade surface was increased. When the cavitation was contracted around the throat located on the pressure side of blade surface, the pressure became high on the pressure side of blade surface. It caused the 1.4 times higher impulsive peak in the torque than the averaged value. On the other hand, when the cavitation was contracted around the throat located on the suction side of blade surface, the pressure became high on the suction side of blade surface. It caused the 0.4 times lower impulsive peak in the torque than the averaged value. The cavitation around the throat caused the large fluctuation in torque acting on the blade.
The purpose of this study was to evaluate the effects of quadriceps femoris flexibility exercise which would improve the degree of knee flexion range of motion, extension torque, and the activities of daily living (ADL) in elderly subjects with degenerative knee arthritis. Fourteen elderly patients (two men and twelve women) with degenerative knee arthritis participated and had a quadriceps femoris flexibility exercise intervention program in this study. The mean age of the patients was 70.00 years for men and 71.16 years for women. This study carried out the experimental study of one group pretest-posttest design, which evaluated the degree of knee flexion range of motion, extension torque, the ADL ability of the patients before and after applying the exercise intervention for five weeks. The results of this study are as follow: 1. The knee flexion ranges of motion of the patients were measured before and after the intervention and the ranges increased significantly both in the left and right knee flexion range of motion (p < 0.05). 2. The peak torque of the knee muscle, the peak torque/body weight, and average power of the patients showed significant increases in both in the left and right knee after applying the intervention (p < 0.05). 3. The intervention produced a significant reduction in pain of the patients (p < 0.05). Their functional activities of ADL improved significantly compared with before the intervention (p < 0.05). It has been shown that the quadriceps femoris flexibility exercise intervention program increased significantly the knee flexion range of motion, and extension torque, as well as an increase in performance of functional activities of ADL of the patients. Thus, the quadriceps femoris flexibility exercise should be considered as one of the therapeutic exercises for the elderly patients with degenerative knee arthritis applied.
Purpose: The purpose of this study was to examine the effects of static stretching and Evjenth-Hamberg stretching on isokinetic muscle strength of knee flexors and extensors. Methods: The subjects were composed of eighty healthy males without weight-training experience. ROM of knee joint measured active maximal extension and isokinetic Peak Torque measured $60^{\circ}/sec,\;120^{\circ}/sec$ using an the En-Knee. Three tests(Baseline, 4 weeks, 8 weeks, respectively) was operated to examine change of each variable. Data were analyzed with a $2{\times}3$ analysis of variance ($group{\times}test$) for repeated measures on last factor by SPSS package 10.0. The data analysis revealed muscle strength were dependent on stretching method. Results: The results were as follows. First, Evjenth-Hamberg stretching(E-HS) was more effective than static stretching(SS) on ROM. Second, Peak Torque of knee flexors and extensors was improved in both methods by each time. but E-HS was more improved than SS. Conclusion: In conclusion, This study indicates that E-HS is more efficient than SS on muscle strength improvement.
Purpose: The purpose of this study was to investigate the differences in FT (free-torque) components between non-fatigue and fatigue conditions induced by prolonged running. Methods: Fifteen healthy runners with no previous lower-extremity fractures ($22.0{\pm}2.1$ years of age) participated in this study. Ground reaction force data were collected for the right-stance phase for 10 strides of 5 and 125-min running periods at 1,000 Hz using an instrumented force platform (instrumented dual-belt treadmills, Bertec, USA) while the subjects ran on it. The running speed was set according to the preferences of the subjects, which were determined before the experiment. FT variables were calculated from the components of the moment and force output from the force platform. A repeated-measures one-way ANOVA was used to test for significant differences between the two conditions. The alpha level for all the statistical tests was 0.05. Results: The absolute FT at the peak braking force was significantly greater after 5 mins of running than after 125 mins of running-which was regarded as a fatigued state-but there were no significant differences in the absolute peak FT or impulse between the conditions. Conclusion: The FT variables in the fatigue condition during prolonged running hardly affect the tibial stress syndrome.
This study was carried out to investigate the muscle strength of quadriceps muscles by means of isokinetic test. The experimental objects were devided into electrically stimulated, isotonic and isometric groups and trained for 4weeks. The results were as follows : 1. the values of total work, peak torque, average power and the ratio of peak torque between flexors and extensors revealed singnificant statistically in three experimental groups(p<0.05). 2. The endurance was increased slightly in electrically stimulated group, but decreased in isotonic and isometric group, 3. The value of post training on all items did not reveal significant statistically in three experimental groups(P>0.05). 4. The electrically stimulated groups effected on increasing of muscle strength as isotonic and isometric exercises.
Kim, Samuel;Jeong, Seung-Ho;Rhyu, Se-Hyun;Kwon, Byung-Il
The Transactions of The Korean Institute of Electrical Engineers
/
v.56
no.1
/
pp.57-65
/
2007
Along with the development of power electronics and magnetic materials, permanent magnet (PM) brushless direct current (BLDC) motors are now widely used in many fields of modern industry BLDC motors have many advantages such as high efficiency, large peak torque, easy control of speed, and reliable working characteristics. However, Compared with the other electric motors without a PM, BLDC motors with a PM have inherent cogging torque. It is often a principle source of vibration, noise and difficulty of control in BLDC motors. Cogging torque which is produced by the interaction of the rotor magnetic flux and angular variation in the stator magnetic reluctance can be reduced by sinusoidal air-gap flux density waveform due to reduction of variation of magnetic reluctance. Therefore, this paper will present a design method of magnetizing system for reduction of cogging torque and low manufacturing cost of BLDC motor with isotropic bonded neodynium-iron-boron (Nd-Fe-B) magnets in ring type by sinusoidal air-gap flux density distribution. An analytical technique of magnetization makes use of two-dimensional finite element method (2-D FEM) and Preisach model that expresses the hysteresis phenomenon of magnetic materials in order for accurate calculation. In addition, For optimum design of magnetizing fixture, Factorial design which is one of the design of experiments (DOE) is used.
Kim, Do-Yon;Kim, Hyon-Kyoung;Baek, Sung-Ho;Jung, Kyung-Soo
Physical Therapy Korea
/
v.1
no.1
/
pp.47-54
/
1994
This study was designed to develop an objective method of strength measurement of muscles controlling the wrist joint in normal subjects. Forty subjects (20 male, 20 female) with a mean age of 22 years, were tested isokinetically at $60^{\circ}/sec$ and $120^{\circ}/sec$. Results were as follows, 1) Peak torque for wrist flexors, extensors were significantly different for both speeds, but wrist ulnar deviator, radial deviator peak torques were not, 2) Mean values for all muscle groups controlling the wrist were not significantly different for both speeds in the female group, 3) All mean values at both $60^{\circ}/sec$ and $120^{\circ}/sec$ were significantly different between males and females, 4) Means and standard deviations of wrist joint angle of movement at peak torque were determined.
The purpose of this study was to investigate the effects of circuit weight training(CWT) on isokinetic muscle strength and body composition in elderly. The subjects who engaged in this experiment exercised at 40$\%$ of 1-RM, 12 repetitions, followed by 15 sec as the subject moved to the each break training program which was consist of the circuit of 10 stations performed on 3 set a day, circuits 3 days a week during 10 weeks. The assessment of isokinetic factor was in concentric flexors and extensors of right and left knee joint. Tests were performed on the Cybex 770 Isokinetic Dynamometer and body composition were estimated the three parts of chest, abdomen and anterior thigh by using skinfold caliper, calculated the average and followed by Seri and Brozek way. Statistical analysis were performed using analysis of variance paired t-test, accepting level for all significant was above $\alpha$=.05 and $\alpha$=.01. Following is as a result of 10 weeks circuit weight training. 1. At the $60_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly (p < .01). 2. At the $180_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly (p < .01). 3. At the $60_{\circ}$ /sec, the right and left knee isokenetic concentric flexors and extensors average power increased significantly(p < 0.5, p < .01) and at the $180_{\circ}$ /sec, the right extensors didn't show any statistical significant. 4. At the $60_{\circ}$ /sec, the right and left knee Isokinetic concentric flexors and extensors total work increased significantly(p < .05, p < .01) but at the $180_{\circ}$ /su right concentric flexors didn't show any statistical significant. 5. The body composition changed significantly(p < .01). These results suggest that 10 weeks circuit weight training increases the peak torque, average power, total work significantly and decreases the $\%$body fat significantly.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.