• Title/Summary/Keyword: peak to peak

Search Result 16,559, Processing Time 0.044 seconds

Peak seismic response of a symmetric base-isolated steel building: near vs. far fault excitations and varying incident angle

  • Pavlidou, Constantina;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • v.18 no.3
    • /
    • pp.349-365
    • /
    • 2020
  • Since the peak seismic response of a base-isolated building strongly depends on the characteristics of the imposed seismic ground motion, the behavior of a base-isolated building under different seismic ground motions is studied, in order to better assess their effects on its peak seismic response. Specifically, the behavior of a typical steel building is examined as base-isolated with elastomeric bearings, while the effect of near-fault ground motions is studied by imposing 7 pairs of near- and 7 pairs of far-fault seismic records, from the same 7 earthquake events, to the building, under 3 different loading combinations, through three-dimensional (3D) nonlinear dynamic analyses, conducted with SAP2000. The results indicate that near-fault seismic components are more likely to increase the building's peak seismic response than the corresponding far-fault components. Furthermore, the direction of the imposed earthquake excitations is also varied by rotating the imposed pairs of seismic records from 0◦ to 360◦, with respect to the major construction axes. It is observed that the peak seismic responses along the critical incident angles, which in general differ from the major horizontal construction axes of the building, are significantly higher. Moreover, the influence of 5% and 10% accidental mass eccentricities is also studied, revealing that when considering accidental mass eccentricities the peak relative displacements of the base isolated building at the isolation level are substantially increased, while the peak floor accelerations and interstory drifts of its superstructure are only slightly affected.

Optimal Operating Method of PV+ Storage System Using the Peak-Shaving in Micro-Grid System (Micro-Grid 시스템에서 Peak-Shaving을 이용한 PV+ 시스템의 최적 운영 방법)

  • Lee, Gi-hwan;Lee, Kang-won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering "demand spike" during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.

Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after aging

  • Abdulrahman A. Balhaddad;Isadora M. Garcia;Haifa Maktabi;Maria Salem Ibrahim;Qoot Alkhubaizi;Howard Strassler;Fabricio M. Collares;Mary Anne S. Melo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.51.1-51.13
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.

Cytomegalovirus Infection in Infantile Hepatitis

  • Na, So Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.15 no.2
    • /
    • pp.91-99
    • /
    • 2012
  • Purpose: The aims of this study was to compare and evaluate the clinical characteristics, laboratory data, and prognosis for infants under age 1 year with CMV hepatitis and those with viral hepatitis of unknown etiology. Methods: A retrospective study was conducted of infants under age 1 year who were admitted with acute hepatitis. The exclusion criteria consisted of: autoimmune, genetic, metabolic, toxic, HAV, HBV, HCV, toxoplasma, rubella, herpes simplex, and Epstein-Barr virus. The 30 patients included were divided into two groups based on markers for CMV (IgM anti-CMV, CMV PCR in urine, CMV culture in urine). Results: The median age of patients (n=15) was 2.8 months. No other organ involvement was detected in any patient. Peak serum total bilirubin levels (n=4) ranged from 2.6 to 6.7 mg/dL. Peak serum ALT levels ranged from 51 to 1,581 IU/L. The duration of ALT elevation ranged from 1.5 weeks to 26 weeks (median 9 weeks). All had recovered in full without ganciclovir; there were no cases of hearing loss. The median age of controls (n=15) was 2.5 months. Peak serum total bilirubin levels (n=4) ranged from 1.6 to 9.1 mg/dL. Peak serum ALT levels ranged from 26 to 1,794 IU/L. No significant differences were observed between both groups regarding the peak serum ALT levels, peak serum total bilirubin levels, duration of hyperbilirubinemia and ALT elevation. Conclusion: Although it was not possible to differentiate congenital infection with perinatal infection in this study, the prognosis of patients with CMV hepatitis without other organ involvement was good without ganciclovir treatment.

A study on the Dynamic Mechanical and Dielectric Loss according to Quenched Condition in Low Density Polyethylene fer Power Cable (전력 케이블용 저밀도 폴리에틸렌의 냉각 조건에 따른 기계적 및 유전손실에 관한 연구)

  • 김재환;권병휘;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.5
    • /
    • pp.27-37
    • /
    • 1992
  • We studied the dielectric and dynamic mechanical losses according to the quenching condition in low density polyethylene being used to power cables. According to severe quenching condition, characteristics of the temperature in internal friction los peak have decreased the magnitude of loss peak as amorphous region lengthen. From now on, the frequency dependent characteristics of dielectric loss have investigated at room temperature, and the dielectric loss peak due to interface polarization, between crystal and amorphous region, occurs about 30[Hz], and that, the peak due to orientation polarization in correspondence to the loss peak in internal friction has observed at about 3 [MHz]. As quenching velocity increased, the effect on quenching condition about the dielectric loss has decreased the magnitude of the loss peak. Thus, estimation has been carried out on the activation energies nd the degree of crystallinity by means of X-ray diffraction are obtained as follows: room quenching : 26.4 [kal/mole] and 54.73 [%], ice quenching : 25.6 [kcal/mole] and 48.47 [%], liquid nitrogen quenching specimens : 22.56 [kcal/mole] and 40.95 [%].

  • PDF

Polarity of Charged Particles n XLPE Measured by Temperature Gradient Thermally Stimulated Surface Potential (온도 구배열자극측정법의한 XLPE하전입자의 극성판정)

  • Kook, Sang-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.4
    • /
    • pp.144-152
    • /
    • 1985
  • This paper temperature gradient thermally stimulated surface potentian (TG-TSSP) in measurements are applied to the study of the polarity of trapped and ionic carriers in cross-linked polyethylene (XLPE) filsm. In the thermally stimulated current in uniform temperature (TSC) of XLPE five peaks appear as indicated of the A B C D and E. In this paper A (at about -120$^{\circ}C$) D (at about 70$^{\circ}C$) and E (at about 110$^{\circ}C$) peaks are investigated. A peak is due to the biassing voltage and biassing temperature. Appear in to the glass transition temperature territory and caused in to the polarization of dipole. D peak is due to the depolarization of ionic space charge and E peak due to the detrapping of carriers injected from the electrodes. TG-TSSP and TSSP are measured to study the polarity of ionic carrier (D peak). In the unsatureated region of ionic space charge polarization, TG-TSSP is lower than TSSP during the initial stage of heating. Result of the experiment for E peak, TG-TSSP is higher than TSSP during the initial stage of heating and these results do not depend on the polarity of biassing voltage, and E peak is concerned with positive carriers (Holes).

  • PDF

Extracting Frequency-Frequency Correlation Function from Two-Dimensional Infrared Spectroscopy: Peak Shift Measurement

  • Kwak, Kyung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3391-3396
    • /
    • 2012
  • Two-dimensional infrared (2D-IR) spectroscopy can probe the fast structural evolution of molecules under thermal equilibrium. Vibrational frequency fluctuation caused by structural evolution produced the time-dependent line shape change in 2D-IR spectrum. A variety of methods has been used to connect the evolution of 2D-IR spectrum with Frequency-Frequency Correlation Function (FFCF), which connects the experimental observables to a molecular level description. Here, a new method to extract FFCF from 2D-IR spectra is described. The experimental observable is the time-dependent frequency shift of maximum peak position in the slice spectrum of 2D-IR, which is taken along the excitation frequency axis. The direct relation between the 2D-IR peak shift and FFCF is proved analytically. Observing the 2D-IR peak shift does not need the full 2D-IR spectrum which covers 0-1 and 1-2 bands. Thus data collection time to determine FFCF can be reduced significantly, which helps the detection of transient species.

Restarting Trains Under Moving Block Signaling - An Expert System Approach

  • K, K.-Wong;Akio, Katuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.96.6-96
    • /
    • 2001
  • A high peak power demand at substations will result under Moving Block Signalling (MBS) when a dense queue of trains begins to start from a complete stop at the same time in an electrified railway system. This may cause the power supply interruption and in turn affect the train service substantially. In a recent study, measures of Starting Time Delay (STD) and Acceleration Rate Limit (ARL) are the possible approaches to reduce the peak power demand on the supply system under MBS. Nevertheless, there is no well-defined relationship between the two measures and peak power demand reduction (PDR). In order to attain a lower peak demand at substations on different traffic conditions and system requirements, an expert system is one of the possible approaches to procure the appropriate use of peak demand reduction measures ...

  • PDF

Novel Peak-to-Average Power Ratio Reduction Methods for OFDM/OQAM Systems

  • Sandeep, Vangala;Anuradha, Sundru
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1124-1134
    • /
    • 2016
  • The tone reservation method is one of the most effective pre-distortion methods for peak-to-average power ratio reduction in orthogonal frequency division multiplexing (OFDM) systems. Its direct application to OFDM systems with offset quadrature amplitude modulation (OQAM) is, however, not effective. In this paper, two novel TR-based methods are proposed, specifically designed for OFDM/OQAM systems by taking into consideration the overlapping nature of OQAM signals. These two methods have different approaches to the generation of the peak-cancelling signal. The first one (overlapped scaling tone reservation) generates the peak-cancelling signal using a least squares approximation algorithm with possible adjacent symbol overlap; the second one (multi-kernel tone reservation) generates the peak-cancelling signal by using multiple impulse-like time domain kernels. It is shown by simulation that, when used in OFDM/OQAM systems, the proposed methods can provide better performance than the direct application of the existing controlled clipping tone reservation method, and even outperform the multi-block tone reservation method.

Clock Scheduling and Cell Library Information Utilization for Power Supply Noise Reduction

  • Kim, Yoo-Seong;Han, Sang-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Power supply noise is fundamentally caused by large current peaks. Since large current peaks are induced by simultaneous switching of many circuit elements, power supply noise can be minimized by deliberate clock scheduling which utilizes nonzero clock skew. In this paper, nonzero skew clock scheduling is used to avoid the large peak current and consequently reduce power supply noise. While previous approaches require extra characterization efforts to acquire current waveform of a circuit, we approximate it only with existing cell library information to be easily adapted to conventional design flow. A simulated annealing based algorithm is performed, and the peak current values are estimated for feasible clock schedules found by the algorithm. The clock schedule with the minimum peak current is selected for a solution. Experimental results on ISCAS89 benchmark circuits show that the proposed method can effectively reduce the peak current.