• Title/Summary/Keyword: peak time

Search Result 4,652, Processing Time 0.043 seconds

Ecological variation between two populations of Thecodiplosis japonensis uchida et Inouye in Korea (솔잎혹파리 두 집단간(集團間)의 생태변이(生態變異))

  • Hwang, Yu Chul;Yim, Kyong Bin
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.2
    • /
    • pp.115-126
    • /
    • 1990
  • This study was performed to find differences in phototaxis response of the larva, adult emergence, sex ratio and gall formation rate of Thecodiplosis japonensis Uchida et Inouye between two areas, north and south. Larvae from these two areas, Hweng-sung in north and Moo-an in south, both considered to be the sities of severe outbreak of the insect recently, were collected from the floor and transported to the entomology larboratory, Won-Kwang University in Iri, then overwintered. These larvae were used for various experimental purposes on various dates. The following results were obtained. 1. The sizes of larvae reached 2.45 in length, 0.70 in width for north, and 2.50 in length, 0.72 in width for sourth. It seems that the differents were not significant. 2. It is known that Leaving gall of larvae to the ground for the hibernation usually occurs on rainy days. For the larvae dispersion, the phototaxis response of the larvae was hypothesized. To check this, the author manipulated some different illumination intensities adjusting the distance between the glass tube in which 100 larvae were contained and electric bulb. The glass tubes were blackened all but except a small portion. The phototaxis responses between two areas seemed to be different particularly at low light intensities, 45, 145 and 1000 lux, The larvae from north assembled to the clear portion of the glass tube were more than 30 out of 100, however less than 30 in south sample regardless of the time passage. In either cases, the saturation points came after about 8 to 10 hours. If temperature units were used, the phototaxis curve= after 1 hour illumination between two areas provided significant differences. 3. The adult emergence of south area was lagged 10 days later than that of north area. The accumulated effective day-degrees of temperature for adult emergence were $934^{\circ}C$ for north area and $1180^{\circ}C$ for south area. The emerging duration of north area appeared to be in late May through the early of July and the peak emergence occurred in middle June that was approximately 15days earlier than that of south area. The sex ratio of female to male, regardless of area, was approximately 3 : 1. 4. The rates of gall formation of the red pine(Pinus densiflora Siebold et Zuccarini), 6-year-old seedlings, were as low as 9.94% for north area and 8.87% for south area. Through the close observation, the author presumed that the population reduction was greatly affected during the prepupa stage by relative moisture content and predators, such as spiders and ants presented on the ground.

  • PDF

Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex (산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구)

  • Oh, Kwang Min;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.65-79
    • /
    • 2019
  • The study attempted to estimate the optimal facility capacity by combining renewable energy sources that can be connected with gas CHP in industrial complexes. In particular, we reviewed industrial complexes subject to energy use plan from 2013 to 2016. Although the regional designation was excluded, Sejong industrial complex, which has a fuel usage of 38 thousand TOE annually and a high heat density of $92.6Gcal/km^2{\cdot}h$, was selected for research. And we analyzed the optimal operation model of CHP Hybrid System linking fuel cell and photovoltaic power generation using HOMER Pro, a renewable energy hybrid system economic analysis program. In addition, in order to improve the reliability of the research by analyzing not only the heat demand but also the heat demand patterns for the dominant sectors in the thermal energy, the main supply energy source of CHP, the economic benefits were added to compare the relative benefits. As a result, the total indirect heat demand of Sejong industrial complex under construction was 378,282 Gcal per year, of which paper industry accounted for 77.7%, which is 293,754 Gcal per year. For the entire industrial complex indirect heat demand, a single CHP has an optimal capacity of 30,000 kW. In this case, CHP shares 275,707 Gcal and 72.8% of heat production, while peak load boiler PLB shares 103,240 Gcal and 27.2%. In the CHP, fuel cell, and photovoltaic combinations, the optimum capacity is 30,000 kW, 5,000 kW, and 1,980 kW, respectively. At this time, CHP shared 275,940 Gcal, 72.8%, fuel cell 12,390 Gcal, 3.3%, and PLB 90,620 Gcal, 23.9%. The CHP capacity was not reduced because an uneconomical alternative was found that required excessive operation of the PLB for insufficient heat production resulting from the CHP capacity reduction. On the other hand, in terms of indirect heat demand for the paper industry, which is the dominant industry, the optimal capacity of CHP, fuel cell, and photovoltaic combination is 25,000 kW, 5,000 kW, and 2,000 kW. The heat production was analyzed to be CHP 225,053 Gcal, 76.5%, fuel cell 11,215 Gcal, 3.8%, PLB 58,012 Gcal, 19.7%. However, the economic analysis results of the current electricity market and gas market confirm that the return on investment is impossible. However, we confirmed that the CHP Hybrid System, which combines CHP, fuel cell, and solar power, can improve management conditions of about KRW 9.3 billion annually for a single CHP system.

The Characteristics of Black Carbon of Seoul (서울의 블랙카본 특성 연구)

  • Park, Jongsung;Song, Inho;Kim, Hyunwoong;Lim, Hyungbae;Park, Seungmyung;Shin, Suna;Shin, Hyejoung;Lee, Sangbo;Kim, Jeongho
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.2
    • /
    • pp.113-128
    • /
    • 2019
  • The concentration and coating thickness of black carbon (BC) were measured along with fine dust in the fall of 2018, at the Seoul Metropolitan Area Intensive Monitoring Station (SIMS). In fall, the concentration of $PM_{10}$ and $PM_{2.5}$ was $23{\pm}12.6{\mu}g/m^3$ and $12{\pm}5.8{\mu}g/m^3$, respectively, lower than that in other seasons. The BC level, measured using an Aethalometer, was $0.73{\pm}0.43{\mu}g/m^3$, while the levels of elemental carbon (EC) and refractory-BC (rBC), measured by semi-continuous carbon analyzer (SOCEC) and single particle soot photometer (SP2), were $0.34{\pm}0.18{\mu}g/m^3$ and $0.32{\pm}0.18{\mu}g/m^3$, respectively. As such, the concentration level differed according to the measurement method, but its time-series distribution and diurnal variation showed the same trends. The BC concentration at SIMS was primarily affected by automobiles with higher levels of BC during morning and evening commuting times due to increased traffic congestion. rBC, measured by SP2, had a peak concentration and coating thickness of 84 nm and 43 nm, respectively. Notably, the coating thickness had an inverse relationship with particle size.

Epidemiology and Clinical Characteristics of Parainfluenza Virus Type 4 in Korean Children: a Single Center Study, 2015-2017 (소아에서 파라인플루엔자 바이러스 4형의 역학 및 임상 양상에 대한 단일기관 연구: 2015-2017)

  • Sohn, Young Joo;Choi, Youn Young;Yun, Ki Wook;Choi, Eun Hwa;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.3
    • /
    • pp.156-164
    • /
    • 2018
  • Purpose: We aimed to identify the epidemiology and the clinical characteristics of human parainfluenza virus type 4 (HPIV-4) infection compared to HPIVs 1-3 infections in Korean children. Methods: We reviewed medical records of children with HPIV infection who visited Seoul National University Children's Hospital from 2015 to 2017. Detection of respiratory viruses was performed using real time-polymerase chain reaction (rt-PCR), which could differentiate HPIVs 1-4. Diagnosis was classified as a febrile illness, upper respiratory tract infection (URI), croup, bronchiolitis, or pneumonia. The epidemiology, demographic features, and clinical characteristics among HPIV types were compared. The clinical data were analyzed only for the previously healthy children. Results: Of the 472 children diagnosed with HPIV infection, 108 (22.9%) were previously healthy: 24 (22.2%), 19 (17.6%), 39 (36.1%), and 26 (24.1%) in HPIV types 1, 2, 3, and 4, respectively. The median age of children with HPIV-4 infection was 11 (0-195) months: the proportion of children aged < 2 years and 2 to < 5 years were 65.4% and 19.2%, respectively. Clinical diagnoses of HPIV-4 infection were bronchiolitis (38.5%), pneumonia (30.8%), and URI (30.8%). Croup was the most prevalent in HPIV-2 (21.1%) and none in HPIV-4 infection (P=0.026). Hospital admission rates among HPIV types were not significantly different (P>0.05). Conclusions: We observed seasonal peak of HPIV-4 infection in 2015 and 2017. HPIV-4 was a common respiratory pathogen causing lower respiratory tract infection in hospitalized children.

Effects of vocal aerobic treatment on voice improvement in patients with voice disorders (성대에어로빅치료법이 음성장애환자의 음성개선에 미치는 효과)

  • Park, Jun-Hee;Yoo, Jae-Yeon;Lee, Ha-Na
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.69-76
    • /
    • 2019
  • This study aimed to investigate the effects of vocal aerobic treatment (VAT) on the improvement of voice in patients with voice disorders. Twenty patients (13 males, 7 females) were diagnosed with voice disorders on the basis of videostroboscopy and voice evaluations. Acoustic evaluation was performed with the Multidimensional voice program (MDVP) and Voice Range Profile (VRP) of Computerized Speech Lab (CSL), and aerodynamic evaluation with PAS (Phonatory Aerodynamic System). The changes in F0, Jitter, Shimmer, and NHR before and after treatment were measured by MDVP. F0 range and Energy range were measured with VRP before and after treatment, and the changes in Expiratory Volume (FVC), Phonation Time (PHOT), Mean Expiratory Airflow (MEAF), Mean Peak Air Pressure (MPAP), and Aerodynamic Efficiency (AEFF) with PAS. Videostroboscopy was performed to evaluate the regularity, symmetry, mucosal wave, and amplitude changes of both vocal cords before and after treatment. Voice therapy was performed once a week for each patient using the VAT program in a holistic voice therapy approach. The average number of treatments per patient was 6.5. In the MDVP, Jitter, Shimmer, and NHR showed statistically significant decreases (p < .001, p < .01, p < .05). VRP results showed that Hz and semitones in the frequency range improved significantly after treatment (p < .01, p < .05), as did PAS, FVC, and PHOT (p < .01, p < .001). The results for videostroboscopy, functional voice disorder, laryngopharyngeal reflux, and benign vocal fold lesions were normal. Thus, the VAT program was found to be effective in improving the acoustic and aerodynamic aspects of the voice of patients with voice disorders. In future studies, the effect of VAT on the same group of voice disorders should be studied. It is also necessary to investigate subjective voice improvement and objective voice improvement. Furthermore, it is necessary to examine the effects of VAT in professional voice users.

Effect of Composition on Isotropic Chemical Shift of Na Silicate and Aluminosilicate Glasses Using Solid State NMR (고상 핵자기공명 분광분석을 이용한 비정질 Na 규산염 및 알루미노규산염 내 조성에 따른 등방성 화학적 차폐 변화 규명)

  • Park, Sun Young;Lee, Sung Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2019
  • Probing the Na environments in Na silicate and aluminosilicate glasses is essential to the macroscopic properties of melts in the Earth. In particular, exploring the atomic structure of Na silicate and aluminosilicate glasses reveals Na-O distance, which plays an important role in transport properties of melts. Here we report the local environment around Na using $^{23}Na$ magic angle spinning (MAS) NMR. We also obtain $^{23}Na$ isotropic chemical shift (${\delta}_{iso}$) of Na silicate and aluminosilicate glasses with varying composition using Dmfit program. The Q mas 1/2 model simulates the experimental results with three simulated peaks while the CzSimple model simulates with one peak. The ${\delta}_{iso}$ decreases with increasing $SiO_2$ content in Na silicate and aluminosilicate glasses. The ${\delta}_{iso}$ increases with increasing $Na_2O$ content in Na-Ca silicate and Na aluminosilicate glasses when the $SiO_2$ content is fixed. Considering the ${\delta}_{iso}$ of Na aluminosilicate glasses available in the previous studies, together with the current simulation results, we confirm that the ${\delta}_{iso}$ has positive correlation with Al / (Al + Si). Those experimental results were reproduced better using Q mas 1/2 model. The disorder of Na in Na silicate and aluminosilicate glasses can be revealed through the simulation of 1D $^{23}Na$ MAS NMR spectra using Dmfit program in a short time.

An Experimental Study on the Hydration Heat of Concrete Using Phosphate based Inorganic Salt (인산계 무기염을 이용한 콘크리트의 수화 발열 특성에 관한 실험적 연구)

  • Jeong, Seok-Man;Kim, Se-Hwan;Yang, Wan-Hee;Kim, Young-Sun;Ki, Jun-Do;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.489-495
    • /
    • 2020
  • Whereas the control of the hydration heat in mass concrete has been important as the concrete structures enlarge, many conventional strategies show some limitations in their effectiveness and practicality. Therefore, In this study, as a solution of controling the heat of hydration of mass concrete, a method to reduce the heat of hydration by controlling the hardening of cement was examined. The reduction of the hydration heat by the developed Phosphate Inorganic Salt was basically verified in the insulated boxes filled with binder paste or concrete mixture. That is, the effects of the Phosphate Inorganic Salt on the hydration heat, flow or slump, and compressive strength were analyzed in binary and ternary blended cement which is generally used for low heat. As a result, the internal maximum temperature rise induced by the hydration heat was decreased by 9.5~10.6% and 10.1~11.7% for binder paste and concrete mixed with the Phosphate Inorganic Salt, respectively. Besides, the delay of the time corresponding to the peak temperature was apparently observed, which is beneficial to the emission of the internal hydration heat in real structures. The Phosphate Inorganic Salt that was developed and verified by a series of the aforementioned experiments showed better performance than the existing ones in terms of the control of the hydration heat and other performance. It can be used for the purpose of hydration heat of mass concrete in the future.

Interpretation of Cultural Landscape at the Geumsidang(今是堂) sibigyung(12 Landscapes) in Miryang, Gyungnam (밀양 금시당(今是堂) 12경의 문화경관 해석)

  • Eom, Tae-Geon;Kim, Soo-Jin;Park, Jung-Lim;Kang, Han-Min;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.1-18
    • /
    • 2011
  • This study has been examined characteristics of Yeoju Lee family, rich group at Miryang in the middle of the Joseon Dynasty, around Geumsidang(今是堂) Lee Gwang-jin remains as a cultural landscape appeared in pictures, poetry, and a strange story. Geumsidang Lee Gwang-jin returned to his old home abandoned the middle government post after the death of Moonjeong queen in socially confused stage and tried to manage an annex to a Geumsidang located in Baekgok of Eungchun riverside, and Geumsidang he managed was affected by his teacher and uncle Wolyoun Lee Tae of a view of nature, filial behavior, and nature management etc. Also, 'Painting of 12 landscapes to Geumsidang' is landscape painting with the actual view not like the '8 landscapes of So-Sang' or '8 landscapes of Sa-Si' which is abstract landscape and Lee Gyeong-hong drew 12 landscapes of Geumsidang that includes Angbong(鶯峰: nightingale peak), Yongdu mountain(龍頭山), Mubong Buddhist temple(舞鳳寺), Maam mountain(馬巖山), Wolyeon-dae(月淵臺), Saindang village(舍人堂村), Youngnam-ru(嶺南樓), Miryang eubseong(密陽邑城), Eyeonso(梨淵沼: pear tree deep water), Yullim(栗林: chestnut tree forest), Miryang river(密陽江), Sammundong fields(沙門野), land and government office owned by Yeoju Lee family as landscape objects. 'Poems of 12 landscapes to Geumsidang' by Lee Yong-gu 11th sons of Lee Gwang-jin was written based on 'Painting of 12 landscapes to Geumsidang', and sang for time, season, and changes of the weather. All 12 poems are all a quatrain with seven Chinese characters in each line consisted of all 28 words, but does not match completely with shown elements in pictures because it is not a simple description of pictures but it is recreated by writer's personality. Therefore these painting shows not only th meaning of filial behavior but also village owned by Yeoju Lee family rich group in Miryang, and these poem recreated the pictures by changing as certain scenic spot with the object of enforcing territory of Yeoju Lee family.

A Study on the Meaning and Mount Effect of Twelve Peaks of Musan in Yongho Garden, Jinju (진주 용호정원(龍虎庭園) 무산십이봉의 경관의미와 축산효과)

  • Lee, Hyun-Woo
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.4
    • /
    • pp.27-39
    • /
    • 2011
  • The study on Musan twelve peaks of Yongho garden in Jinju, Gyeongnam was anticipated to provide data and implication for reproducing similar spaces and modern changes in terms of design factor since it is the prototype of traditional mount for overcoming monotonous geographical features and intriguing changes and interests. The study analyzed and interpreted the symbolism of twelve peaks, principles of space composition and function and effect of visual construction that were pursued by the builder in terms of landscape view, which results are as following. The center of Yongho garden, Yonghoji(龍虎池) is a typical man-made pond for a supportive feng shui feature. It is a supporting equipment to complete the state of feng shui, and the result of strengthening the completion through the connection with the dragon-related name of the place. The shape of Musan twelve peaks looks like an oval form of Geumseongsan(金星山), 2~3.5m in height and 6~12m in diameter. Peaks are estimated as 1.5~3.7m(2.4m in average) in height, $35{\sim}138m^2$($73.4m^2$ in average) in area, and $30.7{\sim}115.0m^3$($62.5m^3$ in average) in volume. Given that Yonghojeong(龍虎亭), Soseon(小船), the site of main building and Yongsanjae(龍山齋) stand in line, Yonghoji was presumed as the state of enlightenment through ascribing the meaning to virtue and secularity. For the intention of realizing Musan twelve peaks, the builder probably had mounted twelve peaks forming the body of dragons with crossing the point corresponding to a head of tiger, and located Musan twelve peaks and Yonghojeong with a representation of dragons holding Cintamani rising into the sky in the center. The middle area near Musan twelve peaks surrounded by peaks like Geumseongsan running north and south shows a multi-structure of multilayer, maintaining the similarity centering on Yonghoji. It is considered the intention of mount planned at the time of Musan twelve peaks construction, caused by similar form harmony. Internalization of progressive realization through concealment and exposure, enframement effect and spatial order like prospect-refuge theory in the mount of Musan twelve peaks is considered the reflection of the intention to increase depth of the view and expectancy through the various degree of exposure and surroundings of each peak and the colorful combination of viewing and shutting. The "closed view" by Musan twelve peaks creates interesting, vivid and attractive recognition of the view, which is more effective in bringing depth of the view and interests in terms of the geographical design, particularly the area around Yonghoji. Moreover, it was identified that the combination of peaks can be formed resulted from the view configuration concerning the location through multilayer effect reveals an island through the other one when viewed from Yonghojeong.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.