• Title/Summary/Keyword: peak set

Search Result 591, Processing Time 0.021 seconds

Analysis of the Ground Reaction Force of Arm Landing during Sports Aerobics (스포츠 에어로빅스 팔착지 동작의 지면 반력 분석)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.115-124
    • /
    • 2002
  • The purpose of this study is to analyze the ground reaction force of arm landing on arm and leg during sports aerobics. Subjects of this study were total 10 players of 5 males and 5 females who have are domain sports aerobics medalists more than the third place in national tournaments. The subjects jumped between the two ground reaction force analyzers, while landing their right hand on the front platform(#1) and their right leg on the rear platform(#2), and the data frequency was set to 200Hz. Findings of this study are as follows; More than 3 times of impact peak force of vertical reaction force acted on arm joint than on leg joint. And, when ground reaction force on foot increased, ground reaction force on hand decreased. 3 impact peaks of curve of ground reaction force were found - Impact Peak 1 incurred on the time the palm lands on the ground, Impact Peak 2 absorbing shock secondarily on wrist joint, and Active Peak incurred on the time of holding the weight while pushing out the severly bent elbow joint.

Optimal Operating Strategy of Distributed Generation Considering Hourly Reliability Worth (시간별 신뢰도 가치를 고려한 분산전원의 최적 운영전략)

  • 배인수;신동준;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.8
    • /
    • pp.457-462
    • /
    • 2003
  • This paper presents an optimal operating strategy of distributed generation (DG) with reliability worth evaluation of distribution systems. Using DG for peak-shaving unit could reduce the overall system operating cost, and using DG for standby power unit could reduce the customer interruption cost. If DG operating cost is less than utility power cost in peak time, DG should be running to reduce the overall system operating cost. When customer interruption cost enlarges, however, standby power strategy may be the better operating strategy than peak-shaving strategy. Selection of whether DG should be operated for peak-shaving or for standby power, needs the accurate reliability worth evaluation and the accurate power cost evaluation. Instead of using annual average reliability worth, the concept of hourly reliability worth is introduced in this paper to determine the optimal operating decision of DG. Applying suggested hourly reliability worth, the distribution companies that possess DG could set up the optimal operating strategy of DG.

Large Solvent and Noise Peak Suppression by Combined SVD-Harr Wavelet Transform

  • Kim, Dae-Sung;Kim, Dai-Gyoung;Lee, Yong-Woo;Won, Ho-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.7
    • /
    • pp.971-974
    • /
    • 2003
  • By utilizing singular value decomposition (SVD) and shift averaged Harr wavelet transform (WT) with a set of Daubechies wavelet coefficients (1/2, -1/2), a method that can simultaneously eliminate an unwanted large solvent peak and noise peaks from NMR data has been developed. Noise elimination was accomplished by shift-averaging the time domain NMR data after a large solvent peak was suppressed by SVD. The algorithms took advantage of the WT, giving excellent results for the noise elimination in the Gaussian type NMR spectral lines of NMR data pretreated with SVD, providing superb results in the adjustment of phase and magnitude of the spectrum. SVD and shift averaged Haar wavelet methods were quantitatively evaluated in terms of threshold values and signal to noise (S/N) ratio values.

Optimized Automatic Noise Level Calculations for Broadband FT-ICR Mass Spectra of Petroleum Give More Reliable and Faster Peak Picking Results

  • Hur, Manhoi;Oh, Han-Bin;Kim, Sung-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2665-2668
    • /
    • 2009
  • A new algorithm for determining noise level is proposed for more reliability in interpreting spectral data for complex Fourier transform ion cyclotron resonance (FTICR) mass spectra of petroleum. In the new algorithm, a moving window with a fixed number of data points was adopted, instead of a fixed m/z width. In the analysis of petroleum, it was found that a moving window of 50,000 or more data points was optimal. This optimized automated peak picking performed well even with frequency-dependant noise in the mass spectrum. Additionally, this fast, automated peak picking algorithm was suitable for the analysis of a large set of samples.

A study on improvement of policing perfomance by usage parameter control in asynchronous transfer mode networks (ATM망에서 사용자 변수 제어에 의한 감시 성능 개선에 관한 연구)

  • 한길성;오창석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1480-1489
    • /
    • 1996
  • In ATM networks there are two methods in traffic control as schemes advancing the quality of service. One is reactive control after congestion and the other which is generally recommended, is preventive control before congestion, including connection admission control on call leel and usage parameter control, network parameter control, priority control and congestion control on cell level. In particular, usage parameter control is required for restricting the peak cell rate of bursy tracffic to the parameter negotiated at call set-up phase since the peak cell rate significantly influences the network quality of service. The scheme for progressing quality of service by usage parameter control is themethod using VSA(Virtual Scheduling Algorlithm) recommended ITU-T. The method using VSSA(Virtual Scheduling Suggested Algorlithm) in this paper is suggested by considering cell delay variation and token rate of leaky bucket, compared VSA and VSANT(Virtual Scheduling Algolithm with No Tolerance) with VSSA which polices violated cell probability of conformed peak cell rate and intentionally excessive peak cell rate. VSSA method using IPP(Interruped Poisson Process) model of input traffic source showed more quality of service than VSA and VSANT methods as usage parameter control because the suggested method reduced the violated cell probability of contformed peak cell rate and intentionally excessive peak cell rate.

  • PDF

The influence of Art Nouveau on 'Crimson Peak' ('Crimson Peak'에 표현된 Art Nouveau 영향)

  • Kim, Ju-ae
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.1
    • /
    • pp.145-160
    • /
    • 2022
  • This study analyzes the influence of the social and cultural background of Art Nouveau on the costumes, architecture, and crafts in the period drama 'Crimson Peak'. This research method captures images of women's costumes, architecture, and crafts in the 'Crimson Peak' and selects and analyzes those with a clear Art Nouveau influence. Edith's costumes are characterized by the Art Nouveau style that emerged in the 1890s, with an hourglass silhouette, pastel colors, soft materials, and organic curved embellishments. Lucille's costumes show characteristics that were prevalent before the 1890s, using bustles, strong colors, and elaborate ornamentation. The architecture is characterized by gothic vertical lines and organic curves, naturalistic patterns featuring animals and plants, and steel and glass materials. The crafts of 'Crimson Peak' are characterized by flexible shapes with strong, organic curves. These costumes, architecture, and crafts share formal elements including waving, twisting, and organic curves and plant-shaped motifs. The influence of social and cultural background of the age of Art Nouveau expressed in movies on formative arts was examined as impressionism appeared in costumes made of pastel colors, thin and see-through materials, medieval Gothic historicism expressed in structures composed of vertical design and religious relief ornament, exoticism appeared in Chinese vase and Japanese-patterned tea sets, naturalism with an animal·plant motif and phenomenon of active social activities of progressive women through women's clothing that elements of men's costume are introduced. This study will provide data for the production of period dramas set at the end of the 19th century.

Similar Movie Retrieval using Low Peak Feature and Image Color (Low Peak Feature와 영상 Color를 이용한 유사 동영상 검색)

  • Chung, Myoung-Beom;Ko, Il-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.8
    • /
    • pp.51-58
    • /
    • 2009
  • In this paper. we propose search algorithm using Low Peak Feature of audio and image color value by which similar movies can be identified. Combing through entire video files for the purpose of recognizing and retrieving matching movies requires much time and memory space. Moreover, these methods still share a critical problem of erroneously recognizing as being different matching videos that have been altered only in resolution or converted merely with a different codec. Thus we present here a similar-video-retrieval method that relies on analysis of audio patterns, whose peak features are not greatly affected by changes in the resolution or codec used and image color values. which are used for similarity comparison. The method showed a 97.7% search success rate, given a set of 2,000 video files whose audio-bit-rate had been altered or were purposefully written in a different codec.

Changes in Total Work, Total Work Ratio, Heart Rate, and Blood Lactate during 75% 1-RM Bench Press Exercise

  • Kim, Ki Hong;Kim, Byung Kwan
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • Background and Objectives This study was conducted to investigate the change of total work and total work ratio for each set, peak heart rate during exercise, and blood lactate for each set during the 5-set bench press exercise at 75% one repetition maximum test (1-RM). Materials and Methods Seven men in their 20s with more than 6 months of experience doing resistance exercises were selected as subjects, and their 1-RM bench press was measured two weeks before the experiment and 75% 1-RM was measured one week before the experiment. In this study, total work was measured for each set, and heart rate was measured during rest and set-by-set exercise. Blood lactate was measured during rest time after each set. The raw data were analyzed by repeated one-way ANOVA. Results Total work and total work ratio decreased from 1 set to 4 sets (p < .05), p < .001), heart rate increased from stable at the start of exercise (p < .001) and decreased between 3 sets and 4 sets (p < .05). Blood lactate increased continuously up to 2 sets (p < .001, p < .01). Conclusion In conclusion, total work and heart rate decreased with muscle fatigue during exercise, and blood lactate continuously increased. The results of this study are expected to be useful references for constructing resistance exercise programs in the future.

An Adaptive Control of Smart Appliances with Peak Shaving Considering EV Penetration (전기자동차 침투율을 고려한 피크 부하 저감용 스마트 기기의 적응적 제어)

  • Haider, Zunaib Maqsood;Malik, Farhan H.;Rafique, M. Kashif;Lee, Soon-Jeong;Kim, Jun-Hyeok;Mehmood, Khawaja Khalid;Khan, Saad Ullah;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.730-737
    • /
    • 2016
  • Electric utilities may face new threats with increase in electric vehicles (EVs) in the personal automobile market. The peak demand will increase which may stress the distribution network equipment. The focus of this paper is on an adaptive control of smart household appliances by using an intelligent load management system (ILMS). The main objectives are to accomplish consumer needs and prevent overloading of power grid. The stress from the network is released by limiting the peak demand of a house when it exceeds a certain point. In the proposed strategy, for each smart appliance, the customers will set its order/rank according to their own preferences and then system will control the household loads intelligently for consumer reliability. The load order can be changed at any time by the customer. The difference between the set and actual value for each load's specific parameter will help the utility to estimate the acceptance of this intelligent load management system by the customers.

Grid Peak Power Limiting / Compensation Power Circuit for Power Unit under Dynamic Load Profile Conditions (Dynamic Load Profile 조건의 전원 장치에 있어서 계통 Peak Power 제한/보상 전력 회로)

  • Jeong, Hee-Seong;Park, Do-Il;Lee, Yong-Hwi;Lee, Chang-Hyeon;Rho, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.376-383
    • /
    • 2022
  • The improved performance of computer parts, such as graphic card, CPU, and main board, has led to the need for power supplies with a high power output. The dynamic load profile rapidly changes the usage of power consumption depending on load operations, such as PC power and air conditioner. Under dynamic load profile conditions, power consumption can be classified into maximum, normal, and standby power. Several problems arise in the case of maximum power. Peak power is generated at the system power source in the maximum-power situation. Frequent generation of peak power can cause high-frequency problems and reduce the life of high-pressure parts (especially high-pressure capacitors). For example, when a plurality of PCs are used, system overload occurs due to peak power generation and causes problems, such as power failure and increase in electricity bills due to exceeded contract power. To solve this problem, a system peak power limit/compensation power circuit is proposed for a power supply under dynamic load profile conditions. The proposed circuit detects the system current to determine the power situation of the load. When the system current is higher than the set level, the circuit recognizes that the system current generates peak power and compensates for the load power through a converter using a super capacitor as the power source. Thus, the peak power of loads with a dynamic load profile is limited and compensated for, and problems, such as high-frequency issues, are solved. In addition, the life of high-pressure parts is increased.