• Title/Summary/Keyword: peak runoff

Search Result 414, Processing Time 0.023 seconds

A Study on First Flush Storage Tank Design for Combined Sewer Overflows (CSOs) Control (합류식하수도 월류수 관리를 위한 초기우수 저류조 설계방안 연구)

  • Son, Bongho;Oa, Seongwook
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.654-660
    • /
    • 2011
  • One of the best way to control Combined Sewer Overflow (CSO) is proposed to construct first flush storage tank. But there is little known parameters for optimum design of these facilities. This study was conducted to get optimum design parameters for a first flush storage tank construction. The optimization of the tank is generally based upon some measure of SS(Suspended Solid) mass holding efficiency. Water quality deterioration of receiving water body happened right after first time occurring rainfall in dry weather seasons. So, design rainfall intensity is used at 2 mm/hr for peak of monthly average intensities of dry seasons. The capacities for each evaluated catchment are designed from 14.4 min to 16.1 min HRT of CSOs flow at design rainfall intensity. Owing to all storage tanks are connected to interception sewer having a redundancy, the suggested volume could be cut down.

Evaluation of Flood Events Considering Correlation between Flood Event Attributes (홍수사상 요소의 상관성을 고려한 홍수사상의 평가)

  • Lee, Jeong Ho;Yoo, Ji Young;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3B
    • /
    • pp.257-267
    • /
    • 2010
  • A flood event can be characterized by three attributes such as peak discharge, total flood volume, and flood duration, which are correlated each other. However, the amount of peak discharge is only used to evaluate the flood events for the hydrological plan and design. The univariate analysis has a limitation in describing the complex probability behavior of flood events. Thus, the univariate analysis cannot derive satisfying results in flood frequency analysis. This study proposed bivariate flood frequency analysis methods for evaluating flood events considering correlations among attributes of flood events. Parametric distributions such as Gumbel mixed model and bivariate gamma distribution, and a non-parametric model using a bivariate kernel function were introduced in this study. A time series of annual flood events were extracted from observations of inflow to the Soyang River Dam and the Daechung Dam, respectively. The joint probability distributions and return periods were derived from the relationship between the amount of peak discharge and the total volume of flood runoff. Applicabilities of bivariate flood frequency analysis were examined by comparing the return period acquired from the proposed bivariate analyses and the conventional univariate analysis.

Large Scale SWAT Watershed Modeling Considering Multi-purpose Dams and Multi-function Weirs Operation - For Namhan River Basin - (다목적 댐 및 다기능 보 운영을 고려한 대유역 SWAT 모형 구축기법 연구 - 남한강 유역을 대상으로 -)

  • Ahn, So Ra;Lee, Ji Wan;Jang, Sun Sook;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.21-35
    • /
    • 2016
  • This study is to evaluate the applicability of SWAT (Soil and Water Assessment Tool) model for multi-purpose dams and multi-function weirs operation in Namhan river basin ($12,577km^2$) of South Korea. The SWAT was calibrated (2005 ~ 2009) and validated (2010 ~ 2014) considering of 4 multi-purpose dams and 3 multi-function weirs using daily observed dam inflow and storage, evapotranspiration, soil moisture, and groundwater level data. Firstly, the dam inflow was calibrated by the five steps; (step 1) the physical rate between total runoff and evapotranspiration was controlled by ESCO, (step 2) the peak runoff was calibrated by CN, OV_N, and CH_N, (step 3) the baseflow was calibrated by GW_DELAY, (step 4) the recession curve of baseflow was calibrated by ALPHA_BF, (step 5) the flux between lateral flow and return flow was controlled by SOL_AWC and SOL_K, and (step 6) the flux between reevaporation and return flow was controlled by REVAPMN and GW_REVAP. Secondly, for the storage water level calibration, the SWAT emergency and principle spillway were applied for water level from design flood level to restricted water level for dam and from maximum to management water level for weir respectively. Finally, the parameters for evapotranspiration (ESCO), soil water (SOL_AWC) and groundwater level fluctuation (GWQMN, ALPHA_BF) were repeatedly adjusted by trial error method. For the dam inflow, the determination coefficient $R^2$ was above 0.80. The average Nash-Sutcliffe efficiency (NSE) was from 0.59 to 0.88 and the RMSE was from 3.3 mm/day to 8.6 mm/day respectively. For the water balance performance, the PBIAS was between 9.4 and 21.4 %. For the dam storage volume, the $R^2$ was above 0.63 and the PBIAS was between 6.3 and 13.5 % respectively. The average $R^2$ for evapotranspiration and soil moisture at CM (Cheongmicheon) site was 0.72 and 0.78, and the average $R^2$ for groundwater level was 0.59 and 0.60 at 2 YP (Yangpyeong) sites.

Change in Fluorescence Characteristics of Dissolved Organic Matter at Inflow Stream per Catchment of Different Land Use (토지이용도가 다른 소유역별 유입하천에서 용존유기물 형광특성 변화)

  • Kim, Sea-Won;Oh, Jong-Min;Lee, Bo-Mi;Choi, Kwang-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.3
    • /
    • pp.292-302
    • /
    • 2011
  • The Lake Sihwa watershed includes industrial, urban, and rural areas simultaneously. In this study, we analyzed the characteristics of dissolved organic matter (DOM) in spatial-temporal runoff patterns at representative sites having different land use in the watershed of Lake Sihwa. The result of synchronous and 3D-EEMs(3-Dimensional Excitation Emission Matrix Spectroscopy) analysis in 4TG (industrial area), fluorescence distribution and variation clearly appeared in the Fulvic-like fluorescence (FLF) and Humic-like fluorescence (HLF) regions along with the Protein-like fluorescence (PLF) region. A characteristic that Peak A (HLF) region fluorescence intensity did not decrease and the HLF region of fluorescence intensity and spatial-temporal changes clearly appeared during rainfall in AS (urban area). The results of fluorescence analysis in MS did not show great changes in PLF and FLF while showing that fluorescence intensity changes over time in the Terrestrial-like fluorescence (THLF) region increased greatly. In conclusion, our results showed significant differences in the runoff characteristics of DOM particularly in industrial, urban and rural area, and these differences should be considered for the efficient controlling of DOM in the watershed.

Design of Edtention Pond and Critical Duration of Design Rainfall in Seoul (유수지 설계를 위한 계획강우의 임계지속기간 -서울 지역을 중심으로-)

  • 이종태;윤세의
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.115-124
    • /
    • 1993
  • This study is to determine the critical duration of design rainfall and to utilize it for the design of detention pond with pump station. To examine the effect of the duration and temporal distribution of the design rainfall, Huff's quartile method is used for the 9 cases of durations ranging from 20 to 240 minutes with 10 years return period, and the ILLUDAS model is used for runoff analysis. The storage ration which is the ratio of maximum storage amounts to total runoff volume, is introduced to determine the critical duration of design rainfall. The duration which maximizes the storage ratio is adopted as the critical duration. This study is applied to 18 urban drainage watersheds with pump station in Seoul, of which the range of watershed area is $0.24-12.70\textrm{km}^2.$ The result of simulation shows that the duration which maximizes storage ration is 30 and 60 minutes on the whole. It is shown also that the storage ration of 2nd- and 3rd-quartile pattern is larger than that of 1st- and 4th-quartile pattern of temporal distribution. A simplified empirical formula for Seoul area is suggested by using the regression analysis between the maximum storage ration and the peak ratio, and can be utilized for the preliminary design and planning of detention pond with pump station.

  • PDF

Determination of Parameters for the Clark Model based on Observed Hydrological Data (실측수문자료에 의한 Clark 모형의 매개변수 결정)

  • Ahn, Tae Jin;Jeon, Hyun Chul;Kim, Min Hyeok
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.121-131
    • /
    • 2016
  • The determination of feasible design flood is the most important to control flood damage in river management. Concentration time and storage constant in the Clark unit hydrograph method mainly affects magnitude of peak flood and shape of hydrograph. Model parameters should be calibrated using observed discharge but due to deficiency of observed data the parameters have been adopted by empirical formula. This study is to suggest concentration time and storage constant based on the observed rainfall-runoff data at GongDo stage station in the Ansung river basin. To do this, five criteria have been suggested to compute root mean square error(RMSE) and residual of oserved value and computed one. Once concentration time and storage constant have been determined from three rainfall-runoff event selected at the station, the five criteria based on observed hydrograph and computed hydrograph by the Clark model have been computed to determine the value of concentration time and storage constant. A criteria has been proposed to determine concentration time and storage constant based on the results of the observed hydrograph and the Clark model. It has also been shown that an exponent value of concentration time-cumulative area curve should be determined based on the shape of watershed.

Real-Time Forecasting of Flood Discharges Upstream and Downstream of a Multipurpose Dam Using Grey Models (Grey 모형을 이용한 다목적댐의 유입 홍수량과 하류 하천 홍수량 실시간 예측)

  • Kang, Min-Goo;Cai, Ximing;Koh, Deuk-Koo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.1
    • /
    • pp.61-73
    • /
    • 2009
  • To efficiently carry out the flood management of a multipurpose dam, two flood forecasting models are developed, each of which has the capabilities of forecasting upstream inflows and flood discharges downstream of a dam, respectively. The models are calibrated, validated, and evaluated by comparison of the observed and the runoff forecasts upstream and downstream of Namgang Dam. The upstream inflow forecasting model is based on the Grey system theory and employs the sixth order differential equation. By comparing the inflows forecasted by the models calibrated using different data sets with the observed in validation, the most appropriate model is determined. To forecast flood discharges downstream of a dam, a Grey model is integrated with a modified Muskingum flow routing model. A comparison of the observed and the forecasted values in validation reveals that the model can provide good forecasts for the dam's flood management. The applications of the two models to forecasting floods in real situations show that they provide reasonable results. In addition, it is revealed that to enhance the prediction accuracy, the models are necessary to be calibrated and applied considering runoff stages; the rising, peak, and falling stages.

The Effect on the Characteristics of Urban Storm Runoff due to the Space Allocation of Design Rainfall and the Partition of the Subbasin (도시유역에서의 강우 공간분포 및 소유역분할이 유출특성에 미치는 영향)

  • Lee, Jong-Tae;Lee, Sang-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.2
    • /
    • pp.177-191
    • /
    • 1997
  • The influences of the space allocation of design rainfall and partition of the subbasin on the characteristics of urban storm runoff was investigated for the 6 drainage basins by applying SWMM model. It show the deviation of -54.68∼18.77% in the peak discharge when we applied the composed JUFF quantiles to the two zones which are divided by upper and lower region of the basin. Then it is compared with the value for the case of using uniform rainfall distribution all over the drainage. Therefore, it would be helpful to decrease the flood risk when we adopt the space distribution of the design rainfall. The effects of the partitioning the drainage on the computing result shows various responses because of the surface characteristics of the each basin such as slope, imperviousness ratio, buy we can get closer result to the measured value as we make the subbasin detailed. If we use the concept of the skewness and area ratio when we determine the width of subbasin, we can improve the computed result even with fewer number of subbasins. We expect reasonable results which close into the measured results in the range of relative error, 25%, when we divide the basin into more than 3 subbasins and the total urban drainage area is less than 10$\textrm{km}^2$.

  • PDF

Characteristics of Stormwater Runoff with respect to Pavement Types (도로 포장방법에 따른 비점오염물질 유출특성 비교)

  • Kim, Cheolmin;Choi, Jiyeon;Lee, Jung Min;Cho, Hyejin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.423-429
    • /
    • 2014
  • Due to high imperviousness rates of the roads, various pollutants originated from vehicle activities and air depositions are accumulated on the road surfaces. The washed-off pollutants can deteriorate the water quality and destroy the aqua-ecosystems with their toxicity. Usually the roads are paved with asphalt and concrete, which can affect on the pollutant concentrations with different frictional forces. Therefore, this research is performed to evaluate the influences of different pavement type on discharged concentrations of pollutant. The results shows the first flush phenomenon was occurred on both pavement types. However, peak concentrations are higher in concrete pavement areas than asphalt pavement because concrete pavement has high contact area with vehicles. The EMCs(Event Mean Concentration) also shows high values in concrete paved roads. As a result of this research, it can be concluded the pavement type is also one of the important affecting factors on pollutant emissions from the roads.

Reliability evaluations of time of concentration using artificial neural network model -focusing on Oncheoncheon basin- (인공신경망 모형을 이용한 도달시간의 신뢰성 평가 -온천천 유역을 대상으로-)

  • Yoon, Euihyeok;Park, Jongbin;Lee, Jaehyuk;Shin, Hyunsuk
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.71-80
    • /
    • 2018
  • For the stream management, time of concentration is one of the important factors. In particular, as the requirement about various application of the stream increased, accuracy assessment of concentration time in the stream as waterfront area is extremely important for securing evacuation at the flood. the past studies for the assessment of concentration time, however, were only performed on the single hydrological event in the complex basin of natural streams. The development of a assessment methods for the concentration time on the complex hydrological event in a single watershed of urban streams is insufficient. Therefore, we estimated the concentration time using the rainfall- runoff data for the past 10 years (2006~2015) for the Oncheon stream, the representative stream of the Busan, where frequent flood were taken place by heavy rains, in addition, reviewed the reliability using artificial neural network method based on Matlab. We classified a total of 254 rainfalls events based on over unrained 12 hours. Based on the classification, we estimated 6 parameters (total precipitation, total runoff, peak precipitation/ total precipitation, lag time, time of concentration) to utilize for the training and validation of artificial neural network model. Consequently, correlation of the parameter, which was utilized for the training and the input parameter for the predict and verification were 0.807 and 0.728, respectively. Based on the results, we predict that it can be utilized to estimate concentration time and analyze reliability of urban stream.