• 제목/요약/키워드: peak power

검색결과 2,626건 처리시간 0.031초

Tight sportswear and physiological function - Effect on muscle strength and EMG activity -

  • Dai, Xiao-Qun;Li, Yu-Ping;Cai, Juan-Juan;Lu, A-Ming;Wang, Guo-Dong
    • 복식문화연구
    • /
    • 제21권4호
    • /
    • pp.606-611
    • /
    • 2013
  • It has been reported that tight sportswear could have complicated influence on physiological function of human body. The purpose of this present study was to investigate the effect of wearing gradient compression tights (GCT) on muscle strength and EMG activity during repeated isokinetic muscle contractions. Four healthy male undergraduate students performed maximal voluntary isokinetic concentric muscle contractions on biomechanical test and training systems with GCT and loose pants as control (Cont) respectively. During each test, the peak torque of extensor and flexor contractions and the surface electromyography (sEMG) of the rectus femoris and medial gastrocnemius was recorded simultaneously, the peak torque was recorded as an indicator of muscle strength, and the average amplitude and mean power frequency of sEMG were calculated as indicators of EMG activity. The results showed that: the peak torque decreased gradually during continuous muscle contractions both when the Cont and GCT were worn, average sEMG and mean power frequency declined along with the repetitions of muscle contractions for both wearing conditions, and the change tendency was consistence with that of peak torque. There was no obvious difference between the peak torque recorded wearing the Cont or wearing GCT, but when GCT were worn, average sEMG was lower and mean power frequency was higher than the Cont condition. In 24 samples obtained from four subjects, 80% of results showed the same trend. So we could make a conclusion that wearing GCT had no obvious effect on the improvement of muscle strength, but it would affect the EMG activity positivly.

상하 운동 반구형 파력 발전기의 최적 형상 조건 수치해석 (Numerical Study on Shape Optimization of a Heaving Hemisphere Wave Energy Converter)

  • 김성재;구원철;허경욱;허상환
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.254-262
    • /
    • 2015
  • 가동 물체형 점흡수식 반구형 파력발전장치의 수면하 형상에 대한 매개변수 연구를 수행하였다. 매개변수로는 반구의 반지름과 흘수를 사용하였고, 각 조건에 따른 반구의 상하운동응답을 분석하여 최적의 반지름과 흘수사이의 관계를 추정하였다. 또한 최대 파력 에너지를 추출하기 위해 PTO 시스템으로 인한 추가 감쇠 계수를 부유체의 방사 감쇠 계수와 동일하게 지정하였다. 부유체의 운동응답 스펙트럼과 추출 파워 스펙트럼을 입사파 스펙트럼 첨두 주파수의 변화에 따라 구하였다. 이를 통해, 가용 파 에너지 추출량의 첨두 주파수가 입사파 스펙트럼의 첨두 주파수보다 약 20% 클 때, 최대 파워 실효치를 갖는 것을 알 수 있었다.

CES 발전소의 최적운용 알고리즘 개발 (Development of Optimal Operation Algorithm about CES Power Plant)

  • 김용하;박화용;김의경;우성민;이원구
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.61-70
    • /
    • 2012
  • Recently due to the increasing of the importance on the green energy is getting higher by implementing EERS(Energy Efficiency Resource Standards) and NA(Negotiated Agreement) such as lacks of natural resources and The United Nations Framework Convention on Climate Change. And the most practical solution is CHP(Combined Heat and Power) which performs the best energy efficiency. This paper developed optimal operation mechanism of CES(Community Energy System) for enhancement of energy efficiency using CHP(Combined Heat and Power), PLB(Peak Load Boiler) and ACC(ACCumulator) capacities. This method optimally operated these capacities calculated the maximum profits by Dynamic Programing. Through the case studies, it is verified that the proposed algorithm of can evaluate availability.

Solar and Heliospheric 1.3-year Signals during 1970-2007

  • Hwang, Junga;Cho, Il-Hyun;Park, Yound-Deuk
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.92.2-92.2
    • /
    • 2013
  • We revisit the 1.3-year (yr) signals observed on the Sun, in the interplanetary space, and in the Earth's magnetosphere to study the coupling among signals from the three regions for about forty years (1970--2007) covering three solar cycles 21, 22, and 23. For this, we make dynamic spectra of datasets including three different regions. From this, we estimate the peak frequency around 1.3 yr for each region and the corresponding band power. We found that coherent power only appears during 1987-1995 and the coherent behavior is found only in the interplanetary space and Earth, not in the Sun. Although the solar surface magnetic field shows significant power around 1.3 yr, their peak frequencies are statistically different from those of the outer regions, which make us to dismiss the existence of coherence among the three regions. But it is notable that the peaks in band power corresponding to the 1.3-yr period are clearly simultaneous in the interplanetary space and Earth.

  • PDF

최대전력수송량 산정기법을 이용한 지역간 수송여유율에 관한 연구 (A Study of Estimating Local Marginal Power Rate Based on Load Supplying Capability Evaluation Method)

  • 남궁재용;이용한;김응상;박동욱;송길영
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.172-179
    • /
    • 1998
  • 본 연구에서는 복합계통의 수송능력을 평가하던 종래의 연구결과를 발견시켜,‘각 지역에 공급되는 전력이 예측된 최대부하에 대해 얼마만큼의 여유가 있는가’를 계산하는 방법을 제안한다. 각 부하모선의 수송여유에 따른 지역간 분할의 내용을 소개하며, 계산과정에서 병목선로도 탐색하도록 하였다. 그 결과 계통에서 취약한 수송여유를 보이는 부하모선의 신뢰도 향상에 관한 자료를 얻을 수 있었다. 제안한 앨고리즘을 IEEE 신뢰도 모델계통에 적용하여 그 유용성을 검증하였다.

  • PDF

A Series Arc Fault Detection Strategy for Single-Phase Boost PFC Rectifiers

  • Cho, Younghoon;Lim, Jongung;Seo, Hyunuk;Bang, Sun-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1664-1672
    • /
    • 2015
  • This paper proposes a series arc fault detection algorithm which incorporates peak voltage and harmonic current detectors for single-phase boost power factor correction (PFC) rectifiers. The series arc fault model is also proposed to analyze the phenomenon of the arc fault and detection algorithm. For arc detection, the virtual dq transformation is utilized to detect the peak input voltage. In addition, multiple combinations of low- and high-pass filters are applied to extract the specific harmonic components which show the characteristics of the series arc fault conditions. The proposed model and the arc detection method are experimentally verified through a boost PFC rectifier prototype operating under the grid-tied condition with an artificial arc generator manufactured under the guidelines for the Underwriters Laboratories (UL) 1699 standard.

공간변조 기법을 위한 새로운 PAPR 감쇄 방법 (New PAPR Reduction Method for Spatial Modulation)

  • 샹위롱;김호준;김홍중;정태진
    • 한국통신학회논문지
    • /
    • 제39A권1호
    • /
    • pp.12-18
    • /
    • 2014
  • In this paper, a new peak-to-average power ratio (PAPR) reduction method for spatial modulation(SM) is presented. By using the matrix with all non-zero elements to precode the signals before transmitting, the transmit power is scattered over all transmit antennas for achieving the goal of PAPR reduction. If this matrix is also an unitary matrix, the distribution of transmit power over transmit antennas will be uniform and it also could retain the characteristic of avoiding inter channel interference (ICI) due to the orthogonality of unitary matrix. In case of a non-ideal amplifier, the proposed method can produce a considerable improvement that increases with a number of transmit antennas in performance. Furthermore, the new scheme achieves an identical performance with conventional one in the case of ideal amplifier.

건물 에너지 저감을 위한 에너지 관리 체계 연구 (A Study on Energy Management System for Energy Saving in Building)

  • 강현준;박재현;박종태;김천석
    • 한국전자통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.787-792
    • /
    • 2015
  • 본 논문은 건물 에너지 저감을 위하여 이기종 인터페이스를 통합한 스마트 게이트웨이, 웹서버 그리고 건물 에너지 관리 시스템 구현방법에 대하여 기술하였으며 제안된 시스템은 건물 내의 에너지 저감을 위하여 서비스 모델과 운영 알고리즘을 적용하여 최대전력과 전력사용량 감축방법을 소개한다.

공동주택에서의 전기자동차 충전기 수용률 설정과 그 제어방법 (Set up a Demand Factor of EV Chargers and Its Control Method in Apartments)

  • 김명수;홍순찬
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.98-105
    • /
    • 2014
  • In this paper, we have analyzed the power consumption property of EVs(Electric Vehicles) chargers established in a public place, proposed reasonable demand factors by the number of established EV chargers and its control method in apartments. The optimization of power system and the suppression of the peak load can be controlled through the proposed demand factors and charging scheduling control algorithm. In this paper, electrical design and an case analysis were carried out on a sample apartment complex to prove the effectiveness of the power system. As a result, emergency power transformer capacity has been reduced by approximately 25%, and we have confirmed that the electric rates saving and the control of peak load value is possible.

Analysis of the Charge Controlled Inductor Current Sensing Peak-Power-Tracking Solar Array Regulator

  • Lee, K.S.;Cho, Y.J.;Cho, B.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.982-986
    • /
    • 1998
  • The peak-power-tracking solar array regulator sensing the inductor current is proposed. Since it uses the inductor current as the solar array output power information, the PPT control scheme can be greatly simplified. The charge controlled two-loop scheme is presented to improve the dynamics due to the inductor current sensing. The comparison between the single-voltage loop controlled system and the two-loop controlled system employing the charge control is presented. This paper also contains the simulation results of that comparison.

  • PDF