• 제목/요약/키워드: peak power

검색결과 2,628건 처리시간 0.026초

Lightweight Single Image Super-Resolution Convolution Neural Network in Portable Device

  • Wang, Jin;Wu, Yiming;He, Shiming;Sharma, Pradip Kumar;Yu, Xiaofeng;Alfarraj, Osama;Tolba, Amr
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.4065-4083
    • /
    • 2021
  • Super-resolution can improve the clarity of low-resolution (LR) images, which can increase the accuracy of high-level compute vision tasks. Portable devices have low computing power and storage performance. Large-scale neural network super-resolution methods are not suitable for portable devices. In order to save the computational cost and the number of parameters, Lightweight image processing method can improve the processing speed of portable devices. Therefore, we propose the Enhanced Information Multiple Distillation Network (EIMDN) to adapt lower delay and cost. The EIMDN takes feedback mechanism as the framework and obtains low level features through high level features. Further, we replace the feature extraction convolution operation in Information Multiple Distillation Block (IMDB), with Ghost module, and propose the Enhanced Information Multiple Distillation Block (EIMDB) to reduce the amount of calculation and the number of parameters. Finally, coordinate attention (CA) is used at the end of IMDB and EIMDB to enhance the important information extraction from Spaces and channels. Experimental results show that our proposed can achieve convergence faster with fewer parameters and computation, compared with other lightweight super-resolution methods. Under the condition of higher peak signal-to-noise ratio (PSNR) and higher structural similarity (SSIM), the performance of network reconstruction image texture and target contour is significantly improved.

스퍼터링 니켈박막 연료극 적용 수소공급 저온 세라믹 연료전지의 초기작동 안정성 평가 (Evaluation of Initial Operation Stability of Hydrogen-Fueled, Low-Temperature Solid Oxide Fuel Cell with Sputtered Ni Thin-Film Anode)

  • 지상훈;김원재;한상종;장향연;박나리;김미선;강성원;임현만;정진홍;안광호;미라툴 매크피로;차석원
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.743-748
    • /
    • 2022
  • The initial operation stability of hydrogen-fueled, solid oxide fuel cell with Ni thin-film anode fabricated by direct current sputtering was evaluated in terms of electrochemical properties such as peak power density, open circuit voltage, overpotential, and alternating current impedance at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively.

Effect of Post-Activation Potentiation according to Sequence of Velocity Using Isokinetic Device on Short-Term Performance of Lower Extremity: Taekwondo Athletes and Healthy Adults

  • Sang-Woo Pyun;Seong-Eun Kim;Jong-Wan Kim;Dongyeop Lee;Ji-Heon Hong;Jae-Ho Yu;Jin-Seop Kim;Hyun Suk Yang;Seong-gil Kim
    • The Journal of Korean Physical Therapy
    • /
    • 제34권6호
    • /
    • pp.298-303
    • /
    • 2022
  • Purpose: The purpose of this study was to figure out how PAP (Post-Activation Potentiation) phenomenon affects short-term performance efficiently. Methods: This study was conducted with 18 Taekwondo athletes and 16 healthy adults. By using isokinetic dynamometer, two different intervention, TDP (Top-down program) and BUP (Bottom-up program), were performed to measure isokinetic parameter; (peak torque: PT, total work: TW, average power: AP, and average torque: AT) of knee extensor for intragroup, intergroup comparison and two-way ANOVA. Results: The Taekwondo athletes group showed statistically significant differences in all isokinetic parameters PT, TW, AP, and AT after TDP (p<0.05). However, in the healthy adult group, the difference in isokinetic parameters according to the exercise sequence was not statistically significant. (p>0.05). PT and TW at TDP were statistically significant (p<0.05) when the rate of change in TDP and BUP was compared and analyzed considering the difference in physical ability between the Taekwondo athlete group and the healthy adult group. However, AP and AT were not statistically significant. Finally, when examining the interaction between the two groups and two exercise sequence according to isokinetic parameters, only TW (p<0.05) showed a statistically significant interaction, while PT (P=0.099), AP (P=0.103), and AT (P=0.096) did not. This study suggests that short-term performance can be improved through the PAP phenomenon when TDP is applied to the Taekwondo group. Conclusion: According to our result, for Taekwondo athletes, if the goal is to improve short-term performance just before the main game, we suggest a training program through TDP.

Aeroelastic modeling to investigate the wind-induced response of a multi-span transmission lines system

  • Azzi, Ziad;Elawady, Amal;Irwin, Peter;Chowdhury, Arindam Gan;Shdid, Caesar Abi
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.231-257
    • /
    • 2022
  • Transmission lines systems are important components of the electrical power infrastructure. However, these systems are vulnerable to damage from high wind events such as hurricanes. This study presents the results from a 1:50 scale aeroelastic model of a multi-span transmission lines system subjected to simulated hurricane winds. The transmission lines system considered in this study consists of three lattice towers, four spans of conductors and two end-frames. The aeroelastic tests were conducted at the NSF NHERI Wall of Wind Experimental Facility (WOW EF) at the Florida International University (FIU). A horizontal distortion scaling technique was used in order to fit the entire model on the WOW turntable. The system was tested at various wind speeds ranging from 35 m/s to 78 m/s (equivalent full-scale speeds) for varying wind directions. A system identification (SID) technique was used to evaluate experimental-based along-wind aerodynamic damping coefficients and compare with their theoretical counterparts. Comparisons were done for two aeroelastic models: (i) a self-supported lattice tower, and (ii) a multi-span transmission lines system. A buffeting analysis was conducted to estimate the response of the conductors and compare it to measured experimental values. The responses of the single lattice tower and the multi-span transmission lines system were compared. The coupling effects seem to drastically change the aerodynamic damping of the system, compared to the single lattice tower case. The estimation of the drag forces on the conductors are in good agreement with their experimental counterparts. The incorporation of the change in turbulence intensity along the height of the towers appears to better estimate the response of the transmission tower, in comparison with previous methods which assumed constant turbulence intensity. Dynamic amplification factors and gust effect factors were computed, and comparisons were made with code specific values. The resonance contribution is shown to reach a maximum of 18% and 30% of the peak response of the stand-alone tower and entire system, respectively.

Characteristics Changes of Floury-type Rice depending on Water Immersion and Heat Treatment Time

  • Seon-Min Oh;Hyun-Jin Park;Yu-Chan Choi;You-Geun Oh;Jeong-Heui Lee;Jeom-Sig Lee;Hye Sun Choi;Jieun Kwak
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2022년도 추계학술대회
    • /
    • pp.314-314
    • /
    • 2022
  • In the production of rice flour, wet milling is a method of milling rice after soaking it in water, and it takes a lot of time and cost from milling to drying. To overcome this problem, the floury type rice was developed for dry milling and it is known to have round starch granules, low content of damaged starch after milling, and a starch structure similar to wheat. Because of its unique properties different from normal rice, it is necessary to research on processing and characteristics of floury-type rice to expand its utility in the food industry. Therefore, this study aimed to prepare the pregelatinized floury type rice (Baromi2) by autoclave and investigate their physicochemical properties. As the heat treatment time increased, the brightness decreased from 83.8 to 76.8, however, both redness and yellowness increased from 0.57 to 4.5 and from 14.58 to 21.13, respectively. Despite of same treatment time, soaking in water (10 min) before autoclaving increased the solubility and swelling power of Baromi2 over 2 times. The peak viscosity of native Baromi2 was over 2000 RVU, on the other hand, there was a significantly decrease to less than 1000 RVU of pregelatinized Baromi2. Heat treatment without immersion caused partial gelatinization of starch, resulting that some starch granules maintaining their integrity. Whereas there were no starch granules in heat treatment with soaking in water due to complete gelatinization. This study would be helpful to the suggestion of using heat-treated floury-type rice as an intermediate material in the food industry in the future.

  • PDF

Observational analysis of wind characteristics in the near-surface layer during the landfall of Typhoon Mujigae (2015)

  • Lin Xue;Ying Li;Lili Song
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.315-329
    • /
    • 2023
  • We investigated the wind characteristics in the near-surface layer during the landfall of Typhoon Mujigae (2015) based on observations from wind towers in the coastal areas of Guandong province. Typhoon Mujigae made landfall in this region from 01:00 UTC to 10:00 UTC on October 4, 2015. In the region influenced by the eyewall of the tropical cyclone, the horizontal wind speed was characterized by a double peak, the wind direction changed by >180°, the vertical wind speed increased by three to four times, and the angle of attack increased significantly to a maximum of 7°, exceeding the recommended values in current design criteria. The vertical wind profile may not conform to a power law distribution in the near-surface layer in the region impacted by the eyewall and spiral rainband. The gust factors were relatively dispersed when the horizontal wind speed was small and tended to a smaller value and became more stable with an increase in the horizontal wind speed. The variation in the gust factors was the combined result of the height, wind direction, and circulation systems of the tropical cyclone. The turbulence intensity and the downwind turbulence energy spectrum both increased notably in the eyewall and spiral rainband and no longer satisfied the assumption of isotropy in the inertial subrange and the -5/3 law. This result was more significant in the eyewall area than in the spiral rainband. These results provide a reference for forecasting tropical cyclones, wind-resistant design, and hazard prevention in coastal areas of China to reduce the damage caused by high winds induced by tropical cyclones.

BaTiO3-Poly Vinylidene Fluoride 복합 압전발전기의 출력특성에 미치는 배합비와 분극의 효과 (Effects of Mixing Ratio and Poling on Output Characteristics of BaTiO3-Poly Vinylidene Fluoride Composite Piezoelectric Generators)

  • 김희태;박상식
    • 한국재료학회지
    • /
    • 제33권12호
    • /
    • pp.517-524
    • /
    • 2023
  • BaTiO3-Poly vinylidene fluoride (PVDF) solution was prepared by adding 0~25 wt% BaTiO3 nanopowder and 10 wt% PVDF powder in solvent. BaTiO3-PVDF film was fabricated by spreading the solution on a glass with a doctor blade. The output performance increased with increasing BaTiO3 concentration. When the BaTiO3 concentration was 20 wt%, the output voltage and current were 4.98 V and 1.03 ㎂ at an applied force of 100 N. However, they decreased when the over 20 wt% BaTiO3 powder was added, due to the aggregation of particles. To enhance the output performance, the generator was poled with an electric field of 150~250 kV/cm at 100 ℃ for 12 h. The output performance increased with increasing electric field. The output voltage and current were 7.87 V and 2.5 ㎂ when poled with a 200 kV/cm electric field. This result seems likely to be caused by the c-axis alignment of the BaTiO3 after poling treatment. XRD patterns of the poled BaTiO3-PVDF films showed that the intensity of the (002) peak increased under high electric field. However, when the generator was poled with 250 kV/cm, the output performance of the generator degraded due to breakdown of the BaTiO3-PVDF film. When the generator was matched with 800 Ω resistance, the power density of the generator reached 1.74 mW/m2. The generator was able to charge a 10 ㎌ capacitor up to 1.11 V and turn on 10 red LEDs.

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • 제32권5호
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

온도상승에 따른 감초(Glycyrrhiza uralensis Fisch.)의 유전자 발현 양상 (The Genes Expression Patterns Induced by High Temperature in Licorice (Glycyrrhiza uralensis F.))

  • 성혜주;정우석
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 추계국제학술대회
    • /
    • pp.56-56
    • /
    • 2020
  • 감초는 다년생 콩과(Leguminocae) 식물로 국내에서 시중가격이 높은 만주감초가 일부 재배되고 있다. 우리나라에서 감초 재배법이 불완전한 상황에서 한반도의 기후변화에 의한 온도 상승은 약용작물의 생산 및 품질에 많은 영향을 미칠 것으로 예상되므로 본 연구에서는 재배환경 중 온도 조건만 조절할 수 있는 온도구배터널(temperature gradient tunnel system)을 이용하여 4개의 T1(외기온도+0.5~1.3℃), T2(+1.3~2.2℃), T3(+2.2~3.2℃), T4(+3.2~4.0℃) 처리로 온도구배 하여 4년생 만주감초(Glycyrrhiza uralensis F.)를 재배하였다. 지하부가 오래된 모주와 신초1의 경우 저온(T1)과 중간구간(T2, T3)에서 초장과 총화수가 우세하였고, 번식이 가장 늦은 신초2의 경우 중간구간(T2, T3)에서의 생육 및 개화반응이 뚜렷했다. 각 온도처리구마다 3개의 감초 개체를 선발하여 모주의 정단으로부터 5개의 성엽을 채취하였다. Reverse transcription quantitative PCR (RT-qPCR)은 AccuPower® GreenStarTM RT-qPCR Master Mix (Bioneer, Korea)를 이용하여 진행되었다. Primer 디자인은 NCBI Primer-blast 프로그램을 사용해 제작하였고 ABI StepOne real time system (Applied Biosystem)의 melting curve analysis에서 one-peak test를 통해 gene specific primer임을 확인하였다. 각 온도처리구의 감초 잎에서 RNA를 추출하였고, RT-qPCR을 통해 감초의 유전자 발현양상을 비교, 분석하였다. Phytochrome interacting factor 4 (PIF4)는 식물 호르몬을 유발하는 전사조절을 조정함으로써 고온 신호전달에 핵심적인 역할을 수행한다. 활성화된 Phytochrome B(PhyB)는 PIF4의 활성을 억제한다고 알려졌다. Eukaryotic initiation factors(eIFs)는 mRNA 번역 개시인자로 유전자 발현과 특정 단백질 생산을 조절하는 역할을 한다. 본 결과는 온도조건에서 반응하는 생리적 변화를 전사체 수준에서 조사 분석하여 생리해석의 기초자료로 활용, 국내 감초 재배를 위한 환경조건 구명 및 적지 선정 기초자료로서 활용을 기대한다.

  • PDF

SAC 강화 학습을 통한 스마트 그리드 효율성 향상: CityLearn 환경에서 재생 에너지 통합 및 최적 수요 반응 (Enhancing Smart Grid Efficiency through SAC Reinforcement Learning: Renewable Energy Integration and Optimal Demand Response in the CityLearn Environment)

  • 이자노브 알리벡 러스타모비치;성승제;임창균
    • 한국전자통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.93-104
    • /
    • 2024
  • 수요 반응은 전력망의 신뢰성을 높이고 비용을 최소화하기 위해 수요가 가장 많은 시간대에 고객이 소비패턴을 조정하도록 유도한다. 재생 에너지원을 스마트 그리드에 통합하는 것은 간헐적이고 예측할 수 없는 특성으로 인해 상당한 도전 과제를 안고 있다. 강화 학습 기법과 결합된 수요 대응 전략은 이러한 문제를 해결하고 기존 방식에서는 이러한 종류의 복잡한 요구 사항을 충족하지 못하는 경우 그리드 운영을 최적화할 수 있는 접근 방식으로 부상하고 있다. 본 연구는 재생 에너지 통합을 위한 수요 반응에 강화 학습 알고리즘을 적용하는 방법을 찾아 적용하는데 중점을 둔다. 연구의 핵심 목표는 수요 측 유연성을 최적화하고 재생 에너지 활용도를 개선할 뿐 아니라 그리드 안정성을 강화하고자 한다. 연구 결과는 강화 학습을 기반으로 한 수요 반응 전략이 그리드 유연성을 향상시키고 재생 에너지 통합을 촉진하는 데 효과적이라것을 보여준다.