• Title/Summary/Keyword: peak power

검색결과 2,626건 처리시간 0.027초

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Electric power generation from treatment of food waste leachate using microbial fuel cell

  • Wang, Ze Jie;Lim, Bong Su
    • Environmental Engineering Research
    • /
    • 제22권2호
    • /
    • pp.157-161
    • /
    • 2017
  • Simultaneous treatment of food waste leachate and power generation was investigated in an air-cathode microbial fuel cell. A TCOD removal efficiency of $95.4{\pm}0.3%$ was achieved for an initial COD concentration of 2,860 mg/L. Maximum power density ranged was maximized at $1.86W/m^3$, when COD concentration varied between 60 mg/L and 2,860 mg/L. Meanwhile, columbic efficiency was determined between 1.76% and 11.07% for different COD concentrations. Cyclic voltammetric data revealed that the oxidation peak voltage occurred at -0.20 V, shifted to about -0.25 V. Moreover, a reduction peak voltage at -0.45 V appeared when organic matters were exhausted, indicating that reducible matters were produced during the decomposition of organic matters. The results showed that it was feasible to use food waste leachate as a fuel for power generation in a microbial fuel cell, and the treatment efficiency of the wastewater was satisfied.

최대수요전력 관리 장치의 부하 예측에 관한 연구 (A Study on the Load Forecasting Methods of Peak Electricity Demand Controller)

  • 공인엽
    • 대한임베디드공학회논문지
    • /
    • 제9권3호
    • /
    • pp.137-143
    • /
    • 2014
  • Demand Controller is a load control device that monitor the current power consumption and calculate the forecast power to not exceed the power set by consumer. Accurate demand forecasting is important because of controlling the load use the way that sound a warning and then blocking the load when if forecasted demand exceed the power set by consumer. When if consumer with fluctuating power consumption use the existing forecasting method, management of demand control has the disadvantage of not stable. In this paper, load forecasting of the unit of seconds using the Exponential Smoothing Methods, ARIMA model, Kalman Filter is proposed. Also simulation of load forecasting of the unit of the seconds methods and existing forecasting methods is performed and analyzed the accuracy. As a result of simulation, the accuracy of load forecasting methods in seconds is higher.

플라즈마 살균용 전원장치에 관한 연구 (A study on power system for plasma sterilization)

  • 강욱중;김영문;문상필;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-54
    • /
    • 2002
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described, For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc.. PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[kHz], 1.8[kW] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템 (Resonance inverter power system for plasma sterilization effective improvement)

  • 김주용;문상필;김종실;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

비주택용 전기난방기구가 우리나라 첨두부하에 미치는 영향 검토 (Investgating Effects of Peak Load of Korean Power System from Electric Heating appliances except House)

  • 김용하;이광성;허동렬;이성준;이용석;우성민;손승기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.442-447
    • /
    • 2006
  • This paper investigates the shadow amount of edifice and according to time zone used by its Electric heating appliances, it is analyzed that Electric Heating Power Load affects Heal power load variation curve. Also, in case that the far infrared ray heating system, which are used as new electric heating system, occupies some of the existing Electric heating appliances, it is analyzed that the Electric heating power load affects the Peak load power in Korea.

  • PDF

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

Damage index sensor for smart structures

  • Mita, Akira;Takahira, Shinpei
    • Structural Engineering and Mechanics
    • /
    • 제17권3_4호
    • /
    • pp.331-346
    • /
    • 2004
  • A new sensor system is proposed for measuring damage indexes. The damage index is a physical value that is well correlated to a critical damage in a device or a structure. The mechanism proposed here utilizes elastic buckling of a thin wire and does not require any external power supply for memorizing the index. The mechanisms to detect peak strain, peak displacement, peak acceleration and cumulative deformation as examples of damage indexes are presented. Furthermore, passive and active wireless data retrieval mechanisms using electromagnetic induction are proposed. The passive wireless system is achieved by forming a closed LC circuit to oscillate at its natural frequency. The active wireless sensor can transmit the data much further than the passive system at the sacrifice of slightly complicated electric circuit for the sensor. For wireless data retrieval, no wire is needed for the sensor to supply electrical power. For the active system, electrical power is supplied to the sensor by radio waves emitted from the retrieval system. Thus, external power supply is only needed for the retrieval system when the retrieval becomes necessary. Theoretical and experimental studies to show excellent performance of the proposed sensor are presented. Finally, a prototype damage index sensor installed into a 7 storey base-isolated building is explained.

OFDM 시스템에서 PAR 감소를 위한 SLM 기법의 성능 분석 (Performance Analysis of SLM Method for PAR Reduction Based on OFDM System)

  • 이상근;이윤현;진성우
    • 한국항행학회논문지
    • /
    • 제10권1호
    • /
    • pp.20-25
    • /
    • 2006
  • 현재 OFDM(Orthogonal Frequency Division Multiplexing)은 다중경로 채널 환경에서 고속 통신에 적합한 방식으로 각광을 받고 있으나, 몇 가지 단점을 지니고 있다. 단일 반송파 방식에 비해 PAR(Peak-to-Average power Ratio)이 높다는 점은 그러한 단점 가운데 하나이다. 신호의 PAR이 높을 경우 고출력 증폭기를 통과하면서 비선형 왜곡이 발생할 수 있고, 이를 방지하기 위해서는 고출력 증폭기의 선형 구간을 비효율적으로 증가시켜야 하는 문제가 발생한다. 본 논문에서는 OFDM의 PAR 감소 기법중 하나의 OFDM 심벌을 나타내는 다수의 신호를 발생(Mapping)시킨 후, 그 중 가장 낮은 PAR을 갖는 신호를 선택해서 전송하는 SLM(Selected Mapping) 기법에 대한 성능을 분석한다.

  • PDF

마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로 (A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제41권4호
    • /
    • pp.67-74
    • /
    • 2004
  • 기존의 버스트 모드 자동전력제어 회로는 데이터 율이 증가함에 따라 마크밀도 변화 영향을 심하게 받아 에러를 야기하였다. 이 문제를 해결하기 위해 높은 데이터 율에서도 마크밀도의 영향을 배제시킬 수 있는 새로운 구조의 첨두 비교기를 고안하고 이를 자동전력제어 회로에 적용하여 마크밀도 변화에 강한 버스트 모드 자동전력제어 회로를 제안하였다. 제안한 자동전력제어 회로 내의 첨두 비교기는 높은 데이터 율에서 뿐만 아니라 광범위한 기준전류 및 차 전류 변화에서도 미소한 마크밀도 변화 영향만을 보여 마크밀도 변화에 매우 강한 특성을 확인 할 수 있었다.