• Title/Summary/Keyword: peak frequency

Search Result 2,163, Processing Time 0.029 seconds

NUMERICAL FLOW VISUALIZATION ANALYSIS AROUND AN OSCILLATING SQUARE CYLINDER (정사각봉의 진동에 의한 유동해석)

  • Ju, M.K.;Ajith Kumar, R.;Sohn, C.H.;Gowda, R.H.L.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.115-119
    • /
    • 2007
  • In this paper, a flow visualization analysis has been carried out on an oscillating square section cylinder, numerically, using a commercially available code CFD-ACE. In this study, the square cylinder is forced to oscillate at different frequencies of excitation, viz., fe/fo=0.5, 1.0 and 2.0 (where, fe is the excitation frequency provided to the cylinder and fo is the natural vortex shedding frequency from the stationary cylinder at a particular Reynolds number (=5200). In all the cases, the peak-to-peak amplitude of oscillation is kept at 32% of the side dimension of the square cylinder. These studies are conducted to understand the influence of frequency of oscillation on the flow field features around the cylinder, particularly the mode of vortex shedding. Results indicate that, the flow field around a square cylinder is very much influenced by the excitation frequency, in particular the vortex shedding mode. It is also found that, the vortex street parameters are significantly influence by the oscillation frequency. Comparison with earlier reported experimental studies has also been attempted in this paper. In appears that, such a numerical exercise (as performed in this paper) is first of its kind. It is believed that, these studies would enable one to understand the mechanisms underlying the flow-induced vibrations of a square section cylinder.

  • PDF

Design of High Frequency Heating Power Supply System Using Peck Current Mode Control (피크전류모드 제어를 적용한 고주파 심부발열 전원장치 설계)

  • Xu, Guo-Cheng;Zheng, Tao;Piao, Sheng-Xu;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.61-65
    • /
    • 2017
  • In this paper a prototype of high frequency heating power supply system based on the high frequency heating principle is designed to take the place of acupuncture, moxibustion, warm dressing treatment and some other traditional physical therapy methods. Which possess the advantages of low cost, convenient, easy operation and good effect. The high frequency heating power supply can generate a pulse voltage of more than 1KV with 300KHz switching frequency to heat the patient's skin. The skin temperature can reach to $41{\sim}42^{\circ}C$. The peak current control method is used to maintain the skin temperature in the designed range. The design of the main circuit is based on the flyback converter topology. An easier and practical design method is proposed in this paper. The power supply system prototype is verified to be stable and reliable by both the simulation and experimental results.

Dynamic response of free-end rod with consideration of wave frequency

  • Kim, Sang Yeob;Lee, Jong-Sub;Tutumluer, Erol;Byun, Yong-Hoon
    • Geomechanics and Engineering
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2022
  • The energy transferred on drill rods by dynamic impact mainly determines the penetration depth for in-situ tests. In this study, the dynamic response and transferred energy of drill rods are determined from the frequency of the stress waves. AW-type drill rods of lengths 1 to 3 m are prepared, and strain gauges and an accelerometer are installed at the head and tip of the connected rods. The drill rods are hung on strings, allowing free vibration, and then impacted by a pendulum hammer with fixed potential energy. Increasing the rod length L increases the wave roundtrip time (2L/c, where c is the wave velocity), and hence the transferred energy at the rod head. At the rod tip, the first velocity peak is higher than the first force peak because a large and tensile stress wave is reflected, and the transferred energy converges to zero. The resonant frequency increases with rod length in the waveforms measured by the strain gauges, and fluctuates in the waveforms measured by the accelerometer. In addition, the dynamic response and transferred energy are perturbed when the cutoff frequency is lower than 2 kHz. This study implies that the resonant frequency should be considered for the interpretation of transferred energy on drill rods.

Heart Beat Interval Estimation Algorithm for Low Sampling Frequency Electrocardiogram Signal (낮은 샘플링 주파수를 가지는 심전도 신호를 이용한 심박 간격 추정 알고리즘)

  • Choi, Byunghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.898-902
    • /
    • 2018
  • A novel heart beat interval estimation algorithm is presented based on parabola approximation method. This paper presented a two-step processing scheme; a first stage is finding R-peak in the Electrocardiogram (ECG) by Shannon energy envelope estimator and a secondary stage is computing the interpolated peak location by parabola approximation. Experimental results show that the proposed algorithm performs better than with the previous method using low sampled ECG signals.

New Peak-to-Average Power Ratio Reduction Scheme for an OFKM-CDMA System (OFDM-CDMA 시스템에서 새로운 PAPR 감쇄기법)

  • 주양익;이연우;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.7B
    • /
    • pp.1320-1325
    • /
    • 2000
  • A very simple and effective peak power reduction scheme for a downlink OFDM-CDMA system is proposed using the relationship between peak-to-average power ratio (PAPR) and out-of-phase autocorrelation. Since power spectrum and autocorrelation function are Fourier transform pair, the PAPR property of the sequences can be estimated by the out-of-phase autocorrelation function of the spreading sequences. Thus, by scrambling the spread data in the frequency domain, we can reduce the sidelobe energy of autocorrelation, and at last, suppress PAPR in the proposed OFDM-CDMA system.

  • PDF

Speech/Music Discrimination Using Spectral Peak Track Analysis (스펙트럴 피크 트랙 분석을 이용한 음성/음악 분류)

  • Keum, Ji-Soo;Lee, Hyon-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.243-244
    • /
    • 2006
  • In this study, we propose a speech/music discrimination method using spectral peak track analysis. The proposed method uses the spectral peak track's duration at the same frequency channel for feature parameter. And use the duration threshold to discriminate the speech/music. Experiment result, correct discrimination ratio varies according to threshold, but achieved a performance comparable to another method and has a computational efficient for discrimination.

  • PDF

An Acoustic Study of Korean and English Voiceless Sibilant Fricatives

  • Sung, Eun-Kyung;Cho, Yun-Jeong
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.37-46
    • /
    • 2010
  • This study investigates acoustic characteristics of English and Korean voiceless sibilant fricatives as they appear before the three vowels, /i/, /$\alpha$/ and /u/. Three measurements - duration, center of gravity and major spectral peak - are employed to compare acoustic properties and vowel effect for each fricative sound. This study also investigates the question of whether Korean sibilant fricatives are acoustically similar to the English voiceless alveolar fricative /s/ or to the palato-alveolar /$\int$/. The results show that in the duration of frication noise, English /$\int$/ is the longest and Korean lax /s/ the shortest of the four sounds. It is also observed that English alveolar /s/ has the highest value, whereas Korean /s/ shows the lowest value in the frequency of center of gravity. In terms of major spectral peak, while English /s/ reveals the highest frequency, English /$\int$/ shows the lowest value. In addition, evidence indicates that there is a strong vowel effect in the fricative sounds of both languages, although the vowel effect patterns of the two languages are inconsistent. For instance, in the major spectral peak, both Korean lax /s/ and tense /$s^*$/ show significantly higher frequencies before the vowel /$\alpha$/ than before the other vowels, whereas both English /s/ and /$\int$/ exhibit significantly higher frequencies before the vowel /i/ than before the other vowels. These results indicate that Korean sibilant fricatives are acoustically distinct from both English /s/ and /$\int$/.

  • PDF

An Efficient Peak Detection Algorithm in Magnitude Spectrum for M-FSK Signal Classification (M-FSK 변조 신호 분류를 위한 효율적인 진폭 스펙트럼의 첨두 검출 방법)

  • Ahn, Woo-Hyun;Seo, Bo-Seok
    • Journal of Broadcast Engineering
    • /
    • v.19 no.6
    • /
    • pp.967-970
    • /
    • 2014
  • An efficient peak detection algorithm in magnitude spectrum is proposed to distinguish the M-frequency shift keying(FSK) signals from other digitally modulated signal. In addition, recognition of the modulation order estimation of FSK signals is also studied based on the fact that the magnitude spectrum of FSK signals reveals the number of peaks equal to the modulation order. When no a priori information about the signals, we utilize the histogram of the magnitude spectrum to determine the threshold which is important factor in peak detection algorithm. The simulation results show high probability of classification under 500 symbols and signal-to-noise ratio(SNR) higher than 4dB.

A Low-N Phase Locked Loop Clock Generator with Delay-Variance Voltage Converter and Frequency Multiplier (낮은 분주비의 위상고정루프에 주파수 체배기와 지연변화-전압 변환기를 사용한 클럭 발생기)

  • Choi, Young-Shig
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.63-70
    • /
    • 2014
  • A low-N phase-locked loop clock generator with frequency multiplier is proposed to improve phase noise characteristic. Delay-variance voltage converter (DVVC) generates output voltages according to the delay variance of delay stages in voltage controlled oscillator. The output voltages of average circuit with the output voltages of DVVC are applied to the delay stages in VCO to reduce jitter. The HSPICE simulation of the proposed phase-locked loop clock generator with a $0.18{\mu}m$ CMOS process shows an 11.3 ps of peak-to-peak jitter.

Evaluation of the Muscle Fatigue Recovery Effect by Indirect Moxibustion Treatment (뜸 시술에 의한 대퇴부 근피로 회복 평가)

  • Lee, Seung-Wook;Kim, Jung-Yoon;Lee, Na-Ra;Kim, Young-Ho;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.59-66
    • /
    • 2011
  • Objectives : This study is aimed to evaluate and objectify the therapeutic effect of moxibustion on muscle fatigue recovery. Methods : To evaluate the therapeutic effect on the muscle fatigue recovery, we compared the fatigue recovery of two groups (non-stimulation group and moxibustion group) by analyzing the EMG and peak torque after strenuous knee exercise of isokinetic contraction. Results : The median frequency (MF) of the moxibustion group was recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Nevertheless, the moxibustion group's peak torque was regained higher than that of the non-stimulation group. Conclusions : We confirmed the therapeutic effect of moxibustion and found that the moxibustion can used as prevention method for musculoskeletal disease.