• Title/Summary/Keyword: peak factors

Search Result 900, Processing Time 0.024 seconds

Application of EOC Images to Developed the GIUH (지형학적순간단위유랑도 분석을 위한 EOC 스테레오 영상 활용)

  • Choi, Hyun;Kang, In-Joon;Hong, Sun-Heun
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.2
    • /
    • pp.91-102
    • /
    • 2004
  • This paper reflects the estimation of using the EOC(Electro-optical Camera) images supporting GIUH(geomorphological instantaneous unit hydrograph) approach. We have analyzed GIUH in its density and frequency distribution by creating a DEM(digital elevation model) for the sub basin produced from the EOC images and examined topographical and hydrological application possibility of the EOC images. In this process, we have topographical basin characteristic analysis that use the remote sensing technique analyzing the DEM creation process of the EOC stereo images by studying the basic topographical hydrology analysis about abstraction technique since it is flirty complex and is more time-consuming than other method. we executed statistical analysis of a basin size and river length using the frequency function after divided lattice spacing applied have to the sub river basin from the image data and the digital map into 10m intervals ranging from 10m to 100m. After comparing and examining the peak and time to peak of the GIUH, we proceeded with a comparative analysis by lattice concerning the topographical divergence rate, area ratio, length ratio. Accumulating the peak and time to peak of the GIUH is altered to non-linear form in accordance to lattice dimension as well as basin factor. It was proved that the lattice dimension is one of the important factors about the peak and time to peak of the GIUH.

Acoustic Characteristics of Watermelon for Internal Quality Evaluation (내부품질 판정을 위한 수박의 음파특성)

  • 최동수;최규홍;이강진;이영희;김만수
    • Journal of Biosystems Engineering
    • /
    • v.27 no.1
    • /
    • pp.59-66
    • /
    • 2002
  • The objectives of the study were to analyze the acoustic characteristics related to the internal quality factors of watermelon(Citrulus Vulgaris Schrad). Among the various internal quality factors, only four factors such as ripeness, inside cavity, yellow belt and blood flesh were considered in this study. Relationships between the internal quality factors, the day after fruit set and the day after harvest were also investigated. Test apparatus was the same as the apparatus described in the previous study(Choi et at., 2000). The selected sample was divided into four groups; 69 samples used for ripeness tests 56 samples for ripeness test along the day after fruit set and for yellow belt detection, 60 samples for ripeness along the day after harvest 44 samples fur blood flesh detection. It was shown that the first peak frequencies shifted to the lower range and the energy ratios of the bandwidths between 0∼550 Hz to the bandwidths between 850∼2500 Hz increased as the day after fruit set elapsed. Since the acoustic responses of the watermelon such as frequency and magnitude began to change from 10 days after harvest, the storage period of watermelon in a normal temperature condition seemed to be approximately 10 days after harvest. The ratios of the first peak amplitude to the maximum peak amplitude fur the sound watermelon showed the higher value than that fur watermelon with cavity inside, and the separation between the sound and cavity inside could be accomplished by the ratio value of 0.25. The energy ratios (0∼550 Hz/850∼2,500 Hz) for the watermelon with cavity inside showed the higher value than 2.3. The frequency characteristics of the yellow belt watermelon appeared mostly in the range of 600∼900 Hz frequencies. The yellow belt watermelon showing the energy spectral density function at this frequency range to be over 70 seemed to be not a marketable commodity, The energy ratios(0∼550 Hz/850∼2,500 Hz) for the blood flesh watermelon showed the higher value than 3.5.

An analysis of runoff characteristic by using soil moisture in Sulma basin (설마천 연구지역에서의 토양수분량을 활용한 유출 발생 특성분석)

  • Kim, Kiyoung;Lee, Yongjun;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.9
    • /
    • pp.615-626
    • /
    • 2019
  • Soil moisture and runoff have very close relationship. Especially the water retention capacity and drainage characteristics of the soil are determined by various factors of the soil. In this study, a total of 40 rainfall events were identified from the entire rainfall events of Sulma basin in 2016 and 2017. For each selected events, the constant-K method was used to separate direct runoff and baseflow from total flow and calculate the runoff coefficient which shows positive exponential curve with Antecedent Soil Moisture (ASM). In addition to that, the threshold of soil moisture was determined at the point where the runoff coefficient starts increasing dramatically. The threshold of soil moisture shows great correlation with runoff and depth to water table. It was founded that not only ASM but also various factors, such as Initial Soil Moisture (ISM), storage capacity of soil and precipitation, affect the results of runoff response. Furthermore, wet condition and dry condition are separated by ASM threshold and the start and peak response are analyzed. And the results show that the response under wet condition occurred more quickly than that of dry condition. In most events occurred in dry condition, factors reached peak in order of soil moisture, depth to water table and runoff. However, in wet condition, they reached peak in order of depth to water table, runoff and soil moisture. These results will help identify the interaction among factors which affect the runoff, and it will help establish the relationship between various soil conditions and runoff.

A Study on Chemical Characteristic of Electrically and Thermally Treated MPPF Capacitor Elements (MPPF 커패시터의 전기적, 열적 열화시 소체의 화학적특성에 관한 연구)

  • Koo, Kyo-Sun;Song, Hyun-Seok;Lee, Dong-Zoon;Kwak, Hee-Ro;Shong, Kil-Mok
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.227-230
    • /
    • 2001
  • This paper divides the factors of an accident into two parts, that are electrical deterioration and thermal deterioration, to analyze a characteristic of the factor of an accident which can break out in the capacitor of metal vaporized polypropylene film. For the purpose of creating capacitor which is caused by electric deterioration, we applied DC overvoltage, induced self-healing and breakdown from element. We applied gradual heat to get an element which is cause by thermal deterioration. The chemical structure of the shape and surface is analyzed by thermogravimetric analyzer (TGA), Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectrometer(FT-IR). As a result, the peak of methylene group came out, in case of electrical deterioration, as observing the self-healing point. However, the peak is disappeared in the heat treated element by 500[$^{\circ}C$], and the peak of carbonyl group which has C=O came out in case of thermal deterioration.

  • PDF

A Study on the Battery Storage Volume Optimization in case of DR Participation for the Minimization of the Customer's Investment Cost (BESS의 DR(Demand Response) 적용 시 수용가의 투자비 최소화를 위한 적정용량산출방법)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2013
  • The BESS(Battery Energy Storage System) is an useful device for load leveling, but the high cost, installation space and safety issues are the main barriers for supplying it widely. The important factor in supplying BESS to customers successfully is the payback period. As most of the H/W cost factors are uncontrollable, the optimization of storage volume can be useful factor in improving payback period. In order to obtain optimized BESS volume, the load factor, demand ratio, peak shaving ratio, electric rates and benefits from DR participation of customer should be analyzed. In this paper, we could verify the peak cutting capability and cost effectiveness under the some proposed conditions and changing value of PCS and battery based on the customers data after volume optimization process was applied, and we can identified the saturation point of load factor and shortening of customer's payback period.

Estimation of Design Flood Runoff in Ungaged Forest Watershed to Reduce Flood Damage within the National Park (국립공원내 홍수피해 저감을 위한 미계측 산림지역의 설계홍수량 추정)

  • Kim, Sang-Min;Im, Sang-Jun;Lee, Sang-Ho;Kim, Hyung-Ho;Ma, Ho-Seop;Jeong, Won-Ok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.107-113
    • /
    • 2009
  • The purpose of this study is to estimate the design flood runoff for ungaged forest watershed to reduce the flood damage in national park. Daewonsa watershed in Jirisan National Park was selected as study watershed, of which characteristic factors were obtained from GIS data. Flood runoff was simulated using SCS unit hydrograph module in HEC-HMS model. SCS Curve Number (CN) was calculated from forest type area weighted average method. Huff's time distribution of second-quartile storm of the Sancheong weather station, which is nearest from study watershed, was used for design flood runoff estimation. Critical storm duration for the study watershed was 3 hrs. Based on the critical duration, the peak runoff for each sub-watershed were simulated. It is recommended to monitor the long-term flow data for major stream stations in National Park for a better reliable peak runoff simulation results.

Adjustment of load correlation coefficient for advanced load management (부하관리 개선을 위한 부하 상관계수 산정에 관한 연구)

  • Park, Chang-Ho;Cho, Seong-Soo;Kim, Gi-Hyun;Im, Jin-Soon;Kim, Du-Bong;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1267-1269
    • /
    • 1999
  • This paper studies on arrangement of load correlation coefficient for advanced load management. To accurate load correlation coefficient, we used two real factors, electrical energy(kWh) and peak load current of pole transformers, acquired by measuring instrument. Out of several correlation equations, we find that the quadratic equation is the most accurate to express peak load current and working electrical energy. If the data is located in the outside of ${\pm}3{\sigma}$ it is discarded. For load management, we rearranged load correlation coefficient considering +2${\sigma}$ at load correlation equation. Comparing conventional load correlation coefficient with rearranged one, we can get the result of error reduced and it is adjacent to the actual data. It will be used peak load forecasting from working electrical energy and we are able to prevent from the damaging of pole transformer due to overload.

  • PDF

A Study on the Correlation Coefficients between Delayed Muscle Soreness after Eccentric Exercise, Muscle Strength, CPK and ALD (원심성 수축 운동 후 지연 된 근육통과 근력, CPK ALD의 상관관계에 대한 연구)

  • Choi Jae-Cheong
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.103-110
    • /
    • 1999
  • The purpose of this study was to analyze the correlation coefficients between delayed muscle soreness after eccentric exercise, muscle strength, CPK, and ALD. Subjects of this study were 9 male students. CPK, ALD that known as the indicators of muscle damage and eccentric strength of the Lt elbow flexors were measured prior to exercise. After measurements Hey Perform an isokinetic eccentric exercise of flexor group of 1 elbow(10 repetitions 3 bouts) by make use of KIN-COM isokinetic device. After exercise, CPK, ALD, and peak torque of elbow flexor group was measured at the just after exercise, 24hr after, 72hr after. Also muscle soreness level was evaluated at same intervals by make use of VAS(visual analog scale). The results were as follows : 1 . There was significant differencess or muscle soreness, CPK, ALD, peak torque with the passage or recovery time (p<0.001). 2. There was negative correlation coefficients between CPK and peak torque at 24hr after(p<0.05). 3. There was positive correlation coefficients between ALD and CPK at 24hr after(p<0.05). 4. There was no correlation coefficients between other variables but ALD was the most important factors that can be explains the muscle sur eness very well.

  • PDF

Study on the Diagnosis of Abnormal Prosthetic Valve

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The two major problems related to the blood flow in replaced prosthetic heart valve are thrombus formation and hemolysis. Reliability of prosthetic valve is very important because its failure means the death of patient. There are many factors affecting the valvular failures and their representatives are mechanical failure and thrombosis, so early noninvasive detection is essentially required. The purpose of this study is to detect the various thromboses formation by using acoustic signal acquisition and its spectral analysis on the frequency domain. We made the thrombosis models using Polydimethylsiloxane (PDMS) and they are thrombosis model on the disc, around the sewing ring and fibrous tissue growth across the orifice of valve. Using microphone and amplifier, we measured the acoustic signal from the prosthetic valve, which is attached to the pulsatile mock circulation system. A/D converter sampled the acoustic signal and the spectral analysis is the main algorithm for obtaining spectrum. Then the spectrum of normal and 5 different kinds of abnormal valve were obtained. Each spectrum waveform shows a primary and secondary peak. The secondary peak changes according to the thrombus model. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. Acoustic measurement has been used as a noninvasive diagnostic tool and is thought to be a good method for detecting possible mechanical failure or thrombus.

Literature Review of Clinical Usefulness of Heavy Ion Particle as an New Advanced Cancer Therapy (첨단 암 치료로서 중입자치료의 임상적 유용성에 대한 고찰)

  • Choi, Sang Gyu
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.413-422
    • /
    • 2019
  • Heavy ion particle, represented carbon ion, radiotherapy is currently most advanced radiation therapy technique. Conventional radiation therapy has made remarkable changes over a relatively short period of time and leading various developments such as intensity modulated radiation therapy, 4D radiation therapy, image guided radiation therapy, and high precisional therapy. However, the biological and physical superiority of particle radiation, represented by Bragg peak, can give the maximum dose to tumor and minimal dose to surrounding normal tissues in the treatment of cancers in various areas surrounded by radiation-sensitive normal tissues. However, despite these advantages, there are some limitations and factors to consider. First, there is not enough evidence, such as large-scale randomized, prospective phase III trials, for the clinical application. Secondly, additional studies are needed to establish a very limited number of treatment facilities, uncertainty about the demand for heavy particle treatment, parallel with convetional radiotherapy or indications. In addition, Bragg peak of the heavy particles can greatly reduce the dose to the normal tissues front and behind the tumor compared to the photon or protons. High precision and accuracy are needed for treatment planning and treatment, especially for lungs or livers with large respiratory movements. Currently, the introduction of the heavy particle therapy device is in progress, and therefore, it is expected that more research will be active.