• 제목/요약/키워드: peak factor

검색결과 990건 처리시간 0.027초

Theoretical Analysis of Chromatographic Peak Asymmetry and Sharpness by the Moment Method Using Two Peptides

  • Choi Du Young;Row Kyung Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.495-499
    • /
    • 2004
  • The analyses of peak shapes in chromatography are useful in operating chroma­tographic system. The asymmetry and sharpness of a chromatographic peak are estimated by the reversed-phase adsorption of two standard peptides (angiotensin II bradykinin) on $C_{18}$ In this work, the average particle diameters of $C_{18}$ were 5 and 15 $\mu$m, while the pore sizes were 100 and 300 A. The composition of the mobile phase was $50/50\;vol.\;{\%}$ of a binary mixture of acetonitrile and water with $0.1\%$ TFA, and the particles were packed in a stainless column ($4.6{\times}150$ mm). The third and the fourth central movement were calculated from the chromatographic elution curves by moment analysis. The peak asymmetry was determined by two theoretical calculations: the asymmetry factor by elution peak analysis and skewness with moment analysis. The sharpness was estimated by the fourth central moment. In this work, the most acceptable skewness was calculated when the pore size was 300 A. The large excess was observed on small pore size.

한국인의 외국어 $/\int/$음에 대한 실험음성학적 연구 (An Experimental Phonetic study of Perception of native Korean speakers on English and German $/\int/$)

  • 이숙향;강현숙
    • 대한음성학회지:말소리
    • /
    • 제40호
    • /
    • pp.1-12
    • /
    • 2000
  • This paper investigated how $/\int/$ in English and German is perceived and interpreted in the loanwords in Korean. $/\int/$ in these languages does not show one-to-one correspondence in Korean: $/\int/$ in the coda position in English and German is perceived as [swi] in Korean while $/\int/$ in the onset position is perceived as [syu]. This paper examined phonetic characteristics of $/\int/$ in English and German through its acoustic analysis and attempted to figure out which factor could explain this surface distribution of [swi] and [syu]; phonological (onset vs. coda) or phonetic (coarticulation) factor. Two acoustic features of $/\int/$ in English and German were examined: duration and energy Peak frequency of the frication noise. German $/\int/$ Perceived as [swi] in Korean showed higher energy Peak frequency and longer duration than that perceived as [syu] in Korean. English iii perceived as [swi] also showed longer duration than that Perceived as [syu] in Korean but energy Peak frequency showed different behavior. English $/\int/$ showed coarticulation with the preceding vowel rather than being affected by its position in the syllable in English. This paper concludes that 1)Phonetic characteristics used are duration and energy Peak frequency of its frication noise when $/\int/$ in English and German are adopted in Korean, 2)duration is used prior to energy peak frequency, which can be used as an enhancing feature.

  • PDF

남자 골프선수의 드라이버 스윙 시 클럽 헤드 스피드 향상을 위한 운동역학적 결정요인 탐색 (Searching of Biomechanical Determination Factor for Improving Club Head Speed during the Driver Swing in Male Golf Players)

  • Jae-Woo Lee;Young-Suk Kim;Jun-Sung Park
    • 한국운동역학회지
    • /
    • 제34권1호
    • /
    • pp.1-8
    • /
    • 2024
  • Objective: The aim of this study was to identify the biomechanical determination factor for improving club head speed during the driver swing in male golf players. Method: Twenty-seven golf players were participated in this study. Eight motion capture cameras (250 Hz) and two force plates (2,000 Hz) were used to collect peak angular velocity and ground reaction force data. It was performed stepwise multiple linear regression analysis and alpha set at .05. Results: The peak plantar flexion angular velocity of the left ankle joint and the peak adduction angular velocity of the right shoulder joint were statistically significant. The peak plantar flexion angular velocity of the left ankle joint and the peak adduction angular velocity of the right shoulder during downswing. Conclusion: It is suggested that applying body conditioning training aimed at improving related body functions to increase maximum plantar flexion angular velocity in the left ankle joint will be effective in improving club head speed.

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

우리나라 하수도시설의 첨두부하율 영향요소 분석 (Analysis of Factors Affecting Peak Loading Coefficient of Sewer Works in Korea)

  • 현인환;이영호
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.877-884
    • /
    • 2011
  • Although peak loading coefficient is one of critical design factors for sewer works, its detailed affecting factors were not analyzed because of limited data availability. This study analyzed the affecting factors on peak loading coefficient with plenty data obtained from several newly constructed sewer works. Simple and multiple regression analysis methods were adopted to analyze the relationships of each variable with or without data filtering. Drainage population, drainage area, population density, and daily sewage flow per person showed very weak relationships under diverse characteristics of cities. However, daily sewage flow per person showed stronger relationships with peak loading when daily sewage flow per person was splitted into two ranges. Population density (i.e., drainage population divided by drainage area) and daily sewage flow per person considerably were related with peak loading coefficient when daily sewage flow per person is less than about 400 Lpcd.

산업용전력사용고객의 최대전력 예측에 의한 변압기용량 산정에 관한 연구 (Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Industrial Customers)

  • 김세동;신화영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2009
  • Contract power conversion factor which is applied to estimate contract power of industrial customers is an important standard to calculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for industrial customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum. minimum and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

Radiation Effects on ${\gamma}$-Ray Irradiated Ethylene Propylene Rubber using Dielectric Analysis

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Lee, Chung;Lim, Kee-Joe
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권2호
    • /
    • pp.48-54
    • /
    • 2003
  • To evaluate the radiation degradation of ethylene propylene rubber (EPR), radiation effects on EPR were investigated by using dielectric analysis and thermal-gravimetric analysis. Permittivity, loss factor, tan$\delta$, and thermal decomposition temperature were observed for ${\gamma}$-ray irradiated EPR. As the radiation dose was increased, the peak temperature of the loss factor and tans of EPR were increased and loss factor and tan$\delta$ at peak temperature were decreased. Activation energies were calculated using loss factor and thermal decomposition for ${\gamma}$-ray irradiated EPR as well. The trends of both calculated activation energies showed the same tendencies as radiation dose was increased.

사무소용빌딩의 최대전력 예측에 의한 변압기용량 산정에 관한 연구 (Recommended Practice for the Assessment of Transformer Capacity by the Forecasting of Peak Power in Office Building Customers)

  • 김세동;유상봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2008
  • Contract power conversion factor which is applied to estimate contract power of general customers IS an important standard to caculate transformer capacity. This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 132 office building customers as to AMR system. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to calculate contract power with characteristics for a regression model for customers which maximum utilization factor of transformer is more than 60%.

  • PDF

Selection of Coupling Factor for Minimum Inductor Current Ripple in Multi-winding Coupled Inductor Used in Bidirectional DC-DC Converters

  • Kang, Taewon;Suh, Yongsug
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.879-891
    • /
    • 2018
  • A bidirectional dc-dc converter is used in battery energy storage systems owing to the growing requirements of a charging and discharging mode of battery. The magnetic coupling of output or input inductors in parallel-connected multi modules of a bidirectional dc-dc converter is often utilized to reduce the peak-to-peak ripple size of the inductor current. This study proposes a novel design guideline to achieve minimal ripple size of the inductor current under bidirectional power flow. The newly proposed design guideline of optimized coupling factor is applicable to the buck and boost operation modes of a bidirectional dc-dc converter. Therefore, the coupling factor value of the coupled inductor does not have to be optimized separately for buck and boost operation modes. This new observation is explained using the theoretical model of coupled inductor and confirmed through simulation and experimental test.

국내 내진설계기준의 지반증폭계수를 활용한 포항지역의 지표면 최대가속도 산출 적절성 검토 (A Study on the Applicability of Amplification Factor to Estimate Peak Ground Acceleration of Pohang Area)

  • 김종관;한진태;곽태영
    • 한국지반공학회논문집
    • /
    • 제36권11호
    • /
    • pp.21-33
    • /
    • 2020
  • 본 연구에서는 국내 내진설계기준 공통적용사항(MOIS, 2017)의 지반증폭계수를 활용하여 지표면 최대가속도를 산출하는 방법의 적절성을 검토하기 위해 포항지역 전역의 시추공을 대상으로 1차원 등가선형해석프로그램을 통해 지반응답해석을 수행하였다. 지반응답해석을 위한 지진파는 내진설계기준 공통적용사항에 따라 지진 재현주기 500년, 1000년, 2400년의 표준설계응답스펙트럼에 맞추었고, 지반데이터는 국토지반정보 포털시스템을 활용하여 확보하였다. 그 결과 내진설계기준 공통적용사항에서 제시하는 응답스펙트럼과 지반응답해석에서 얻어진 응답스펙트럼은 지반분류에 상관없이 대략적으로 일치하는 것을 알 수 있었다. 하지만, 증폭계수를 활용하여 지표면최대가속도를 산출할 경우 지반응답해석에서 얻어진 결과와 상당한 차이를 나타내는 것을 알 수 있었다.