• Title/Summary/Keyword: peak efficiency

Search Result 1,105, Processing Time 0.035 seconds

Noise Reduction Method and Sources of Cyclone Sound for Vacuum Cleaner (청소기용 Cyclone 소음원 및 저감방법)

  • Lee, Jun-Hwa;Hong, Seung-Gee;Joo, Jae-Man;Oh, Sang-Kyoung;Song, Hwa-gyu;Oh, Jang-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.452-456
    • /
    • 2005
  • Cyclone is widely adopted in the vacuum cleaner, because of the simple structure, the high dust collection efficiency and its transparency feature, which can be shown to the customer. At past times, cyclone performance was represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, pressure drop of cyclone and it's noise were measured at the variation of the cyclone structure and the main sources of cyclone peak noise was found by experimental and numerical analysis. In addition, the structure for peak noise reduction was suggested and it is beneficial both pressure drop and noise reduction.

An Experimental Study on the Characteristics for Open-Tube and Closed-Tube Thermoacoustic Effects (2)- The 2nd, 3rd Harmonic (개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(2) - 2차, 3차 하모닉)

  • 송규조;박종호;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.135-139
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were built. In order to determine the optimum length of resonant tube and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850mm. The experimental frequency varies from 100Hz to 1000Hz. In case of the second and third harmonics, the maximum temperature difference of open-tube thermoacoustic apparatus is 53$^{\circ}C$ (resonator length: 400mm) and the maximum temperature difference of closed-tube thermoacoustic apparatus is 51$^{\circ}C$ (resonator length: 500mm). In the open-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 55%, 69% in the resonant tube and in the closed-tube thermoacoustic apparatus, the peak efficiency point is about 2%, 41%, 50% in the resonant tube.

TOP-EMISSION CHARACTERISTICS OF ORGANIC LIGHT-EMITTING DIODES (유기발광소자의 전면 발광 특성)

  • Shin, Eun-Chul;Park, Il-Heung;Lee, Ho-Shik;Cho, Sung-Ho;Min, Hang-Gi;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.58-59
    • /
    • 2007
  • We have fabricated top-emission. organic ligth-emitting diodes in a structure of Glass/Al/2-TNATA/TPD/$Alq_3$/LiF/Al/Ag. By varying a film thickness of 2-TNATA and TPD, current efficiency, luminance efficiency, and viewing angle dependence of the device were measured. The top device using $Alq_3$ showed electroluminescent peak wavelengths of 522nm and 505nm at $0^{\circ}$ and $60^{\circ}$ viewing angles, respectively. It is thought that a microcavity effect affects on peak wavelength position for different viewing angles.

  • PDF

Noise Reduction Method and Sources of Cyclone for Vacuum Cleaner (청소기용 Cyclone 소음원 및 저감방법)

  • Lee, Jun-Hwa;Hong, Seung-Gee;Joo, Jae-Man;Oh, Sang-Kyong;Song, Hwa-Gyu;Oh, Jang-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.89-92
    • /
    • 2004
  • Cyclone is widely apoted in the vacuum cleaner, because of it's simple structure, the dust collection efficiency is high and its transparency feaure which can be shown to the customer. At past times, cyclone performance is represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, cyclone's pressure drop and noise is measured at the variation of the cyclone structure and the main sources of cyclone peak noise is found by experiments and numerical analysis. In addition, the structure for peak noise reduction is suggested and it is beneficial both pressure drop and noise reduction.

  • PDF

An Evaluation of Peak-Load Management in DSM Programs (부하관리 요금제 피크억제량 산정 개선방안 연구)

  • Kim, Jin-Ho;Hong, Jun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.572-573
    • /
    • 2008
  • Demand side management can be defined as series of planning and programs to change the electric usage pattern of customers from their normal ones with a least cost while meeting customers electric demand. In general, conventional demand side management programs can be classified into two groups, one of which is a load management and the other is energy efficiency. In this paper, the load management tariff programs in Korea are explored in terms of their effect on the peak demand reduction.

  • PDF

Utilization Efficiencies of Electric Energy and Photosynthetically Active Radiation of Lettuce Grown under Red LED, Blue LED and Fluorescent Lamps with Different Photoperiods

  • Lee, Hye In;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.279-286
    • /
    • 2013
  • Purpose: This study was conducted to analyze the utilization efficiencies of electric energy and photosynthetically active radiation of lettuce grown under red LED, blue LED and fluorescent lamps with different photoperiods. Methods: Red LED with peak wavelength of 660 nm and blue LED with peak wavelength of 450 nm were used to analyze the effect of three levels of photoperiod (12/12 h, 16/8 h, 20/4 h) of LED illumination on light utilization efficiency of lettuce grown hydroponically in a closed plant production system (CPPS). Cool-white fluorescent lamps (FL) were used as the control. Photosynthetic photon flux, air temperature and relative humidity in CPPS were maintained at 230 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $22/18^{\circ}C$ (light/darkness), and 70%, respectively. Electric conductivity and pH were controlled at 1.5-1.8 $dS{\cdot}m^{-1}$ and 5.5-6.0, respectively. The light utilization efficiency based on the chemical energy converted by photosynthesis, the accumulated electric energy consumed by artificial lighting sources, and the accumulated photosynthetically active radiation illuminated from artificial lighting sources were calculated. Results: As compared to the control, we found that the accumulated electric energy consumption decreased by 75.6% for red LED and by 70.7% for blue LED. The accumulated photosynthetically active radiation illuminated from red LED and blue LED decreased by 43.8% and 33.5%, respectively, compared with the control. The electric energy utilization efficiency (EEUE) of lettuce at growth stage 2 was 1.29-2.06% for red LED, 0.76-1.53% for blue LED, and 0.25-0.41% for FL. The photosynthetically active radiation utilization efficiency (PARUE) of lettuce was 6.25-9.95% for red LED, 3.75-7.49% for blue LED, and 2.77-4.62% for FL. EEUE and PARUE significantly increased with the increasing light period. Conclusions: From these results, illumination time of 16-20 h in a day was proposed to improve the light utilization efficiency of lettuce grown in a plant factory.

The Characteristics of the Discharge According to ITO Gap by the CLHS Driving Method in AC PDP (AC PDP에서 CLHS 구동 방법에 의한 ITO Gap에 따른 방전 특성)

  • Shin, Jae-Hwa;Choi, Myung-Gyu;Kim, Gun-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • In order to reduce the power consumption in international standard IEC62087, the luminance efficiency should be improved at the low discharge load rather than at the high discharge load. Thus, this paper analysed the characteristics of the discharge at the panels with ITO Gap of $65{\mu}m$, $80{\mu}m$, and $100{\mu}m$ in 50-inch PDP with FHD resolution. It was well known that the long gap panel improves the luminance and the luminous efficiency. However, it is very difficult to drive the panel due to high driving voltage. When the normal driving method was applied at the panel with ITO gap of $100{\mu}m$, the phenomenon of the double peak was generated in the sustain period. We confirmed that main factor of the double peak is the self-erasing discharge. When the CLHS driving method was applied at the panel with ITO gap of $100{\mu}m$, the self-erasing discharge was improved in the sustain period. Also, the $V_S$ and $V_A$ minimum voltage of the CLHS driving method decreased about 9V and 12V compared with those of the normal driving method. Moreover, when the CLHS driving method was applied to the panel with ITO gap of $100{\mu}m$, the luminance and the luminous efficiency increased compared with those of the normal driving method. The luminance and the luminous efficiency greatly increased at the low discharge load. The less discharge load, the higher increase rate of the luminance and the luminous efficiency. Especially, the luminous efficiency at ITO gap of $100{\mu}m$ increased about 26.3% at the discharge load of 4% compared with that at ITO gap of $65{\mu}m$.

Blood Urea Nitrogen as an Index of Feed Efficiency and Lean Growth Potential in Growing-Finishing Swine

  • Whang, K.Y.;Easter, R.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.6
    • /
    • pp.811-816
    • /
    • 2000
  • Five experiments were conducted to evaluate blood urea nitrogen (BUN) as a potential index of feed efficiency (G/F) and lean growth in growing-finishing pigs. Exp. 1 was conducted to examine the relationship between feeding protocol and BUN values. Fasted-refed pigs exhibited BUN peaks 3 h post-prandially while those given ad libitum access to diet had inconsistent BUN patterns in 10 h blood sampling with an 1 h interval. In Exp. 2 and 3, it was revealed that the peak BUN values were negatively correlated (p<0.01) with G/F in both barrows and gilts at 20 kg body weight (BW) and 50 kg to 90 kg BW. In Exp. 4, it was found that BUN values between 55 kg and 70 kg BW, when lean gain is maximized, were best correlated with average daily lean gain (ADLG). In Exp. 5, 18 barrows and 21 gilts were used to examine the relationship between BUN values at 65 kg BW and ADLG from birth to market weight. The BUN values at 65 kg BW and ADLG were negatively correlated (p<0.01) in both genders. These experiments demonstrated that there was a correlation between peak BUN values, and G/F and ADLG under specific circumstances.

A Study of Counting Efficiency according to the Window-width on Radionuclides $^{131}I\;and\;^{198}Au$ (방사성핵종(放射性核種) $^{131}I$$^{198}Au$에서 Window 폭(幅)에 따른 계수측정(計數測定)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.85-92
    • /
    • 1984
  • It is a esperimental report to investigation for optimum window-width on radionuclides $^{131}I\;and\;^{198}Au$ The obtained results were as follow; 1. In case of $^{131}I$, 1) The lowest counts produced at the window-width of 10KeV and 20KeV. 2) The count rate, more increased, when the window-width more opened, but the counting efficiency is very good between 70KeV and 130KeV window-width (19.23% -35.71% about the peak energy). 3) The heighest counting rate per KeV of window appeared at 130KeV window-width. 4) BKG counts increased proportionally to the wider window as 5.473 + 0.016 cpm. 2. In case of $^{198}Au$ 1) The lowest counts appeared at 10KeV and 20KeV window. 2) Count rate more increased, when window-width more opened, but the counting efficiency is very good between 80KeV and 140KeV window (19.46% - 34.06% about the peak energy). 3) The highest counting rate per KeV of the window appeared at 140KeV window. 4) BKG counts increased proportionally to the wider window-width as 4.74 + 1.09 cpm.

  • PDF

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.