• 제목/요약/키워드: peak efficiency

검색결과 1,105건 처리시간 0.027초

황산염용액으로부터 전기도금 된 FCCL용 Cu 필름의 특성에 미치는 Cu 이온농도 및 첨가제의 영향 (Effect of Cu2+ Concentration and Additives on Properties of Electrodeposited Cu Thin Films for FCCL from Sulfate Baths)

  • 신동율;박덕용;구본급
    • 한국표면공학회지
    • /
    • 제42권5호
    • /
    • pp.191-196
    • /
    • 2009
  • Nanocrystalline Cu thin films were electrodeposited from sulfate baths and investigated systematically the influences of $Cu^{2+}$ concentration and additives on current efficiency, residual stress, surface morphology, and XRD patterns of electrodeposited Cu film. Current efficiency was nearly 100% at from 0.2M to 1.0 M $Cu^{2+}$ concentration. but it was linearly increased with $Cu^{2+}$ concentration at less than 0.2M. The residual stress was observed in range of 7.9 to 18.4 MPa and tensile stress mode. Dendritic and powdered form was obtained at below 0.1 M. As increased with $Cu^{2+}$ concentration in solution, the main peak in the XRD pattern shifted (111) and (220) from (200). In the other hand, all about 100% current efficiency observed in all additive concentration systems, and residual stress observed in range of 20.4 to 26.3 MPa tensile stress. The condition 5(Ultra make-up - 10 ml/l, Ulta A - 0.5ml/l, Ultr B - 0.5 ml/l) was good surface morphology, and fcc(111) peak in XRD patterns increased with increasing additive concentration.

Genetic Studies on Production Efficiency Traits in Hariana Cattle

  • Dhaka, S.S.;Chaudhary, S.R.;Pander, B.L.;Yadav, A.S.;Singh, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권4호
    • /
    • pp.466-469
    • /
    • 2002
  • The data on 512 Hariana cows, progeny of 20 sires calved during period from 1974 to 1993 maintained at Government Livestock Farm, Hisar were considered for the estimation of genetic parameters. The means for first lactation milk yield (FLY), wet average (WA), first lactation peak yield (FPY), first lactation milk yield per day of first calving interval (MCI) and first lactation milk yield per day of age at second calving (MSC) were 1,141.58 kg, 4.19 kg/day, 6.24 kg/day, 2.38 kg/day and 0.601 kg/day, respectively. The effect of period of calving was significant (p<0.05) on WA, FPY and MCI while the effect of season of calving was significant only on WA. Monsoon calvers excelled in performance for all the production efficiency traits. The effect of age at first calving (linear) was significant on all the traits except on MCI. Estimates of heritabilty for all the traits were moderate and ranged from 0.255 to 0.333 except for WA (0.161). All the genetic and phenotypic correlations among different production efficiency traits were high and positive. It may be inferred that selection on the basis of peak yield will be more effective as the trait is expressed early in life and had reasonably moderate estimate of heritability.

압축기 출구 물분사가 있는 재생 가스터빈 시스템의 성능해석 (Performance Analysis of Regenerative Gas Turbine System with Afterfogging)

  • 김경훈;김세웅;고형종
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.448-455
    • /
    • 2009
  • A performance analysis of the regenerative gas turbine system with afterfogging is carried out. Because of the high temperature at the outlet of air compressor, afterfogging has a potential of improved recuperation of exhaust heat than inlet fogging. Thermodynamic analysis model of the gas turbine system is developed by using an ideal gas assumption. Using the model, the effects of pressure ratio, water injection ratio, and ambient temperature are investigated parametrically on thermal efficiency and specific power of the cycle. The dependency of pressure ratio giving peak thermal efficiency is also investigated. The results of numerical computation for the typical cases show that the regenerative gas turbine system with afterfogging can make a notable enhancement of thermal efficiency and specific power. In addition, the peak thermal efficiency is shown to decrease almost linearly with ambient temperature.

Improving the Overall Efficiency for DC/DC Converter with LoV-HiC System

  • Han, Dong-Hwa;Lee, Young-Jin;Kwon, Wan-Sung;Bou-Rabee, Mohammed A.;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.418-428
    • /
    • 2012
  • It is very important to improve the overall efficiency of systems with a source of power that has low-voltage high-current terminal characteristics such as fuel cells. A resonant converter is required for high efficiency systems. However, the peak value of the switches current is large in a resonant converter. This peak current requires a large number of switches and results in system failures. In this paper, an analysis and experiments of a resonant isolation push-pull converter are performed. A switching loss analysis is performed in order to compare losses between a resonant push pull converter and a hard switching push-pull converter. Specially, the conduction loss is studied based on the ratio between the resonant frequency and the switching frequency. In addition, a method for improving the efficiency is implemented with conventional HF insolation converters.

압전식 충격파 체외 쇄석기 사용시 초점위치에 의한 대상물의 진동과 파쇄효율과의 상관성 (The Relativity between Vibration of Phantom and Its Break Efficiency Due to Position of Focus Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter)

  • 장윤석
    • 한국음향학회지
    • /
    • 제19권5호
    • /
    • pp.35-40
    • /
    • 2000
  • 본 연구에서는 먼저 압전형 쇄석기에 의한 충격파 조사시에 발생하는 파쇄대상물의 진동과 그 때 들려오는 방사음과의 관계에 대하여 검토한다. 다음에 대상물에 있어서의 초점위치와 고유진동과의 관계에 대해서도 조사한 결과를 제시한다. 아울러 동일한 실험을 파쇄가능한 대상물에 시행하여 대상물의 진동과 그 파쇄효율과의 관계에 대해서도 실험적으로 검토한다. 그 결과, 초점위치에 따른 대상물 고유진동의 피크 주파수 파워와 파쇄효율과의 상관성을 명확히 확인할 수 있었다.

  • PDF

Background reduction by Cu/Pb shielding and efficiency study of NaI(TI) detector

  • Ramadhan, Revink A.;Abdullah, Khairi MS.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.462-469
    • /
    • 2018
  • The background spectrum of a $3^{{\prime}{\prime}}{\times}3^{{\prime}{\prime}}$ NaI(Tl) well-type scintillation SILENA detector was measured without shielding, in 6 cm thick lead shielding, and with 2 mm thick electrolytic copper covering the detector inside the lead shielding. The relative remaining background of the lead shield lined with copper was found to be ideal for low-level environmental radioactive spectroscopy. The background total count rate in the (20-2160 KeV) was reduced 28.7 times by the lead and 29 times by the Cu + Pb shielding. The effective reduction of background (1.04) by the copper mainly appeared in the energy range from X-ray up to 500 KeV, while for the total energy range the ratio is 1.01 relative to the lead only. In addition, a strong relation between the full-energy peak absolute efficiency and the detector well height was found using gamma-ray isotropic radiation point sources placed inside the detector well. The full-energy peak efficiency at a midpoint of the well (at 2.5 cm) is three times greater than that on the detector surface. The energy calibrations and the resolution of any single energy line are independent of the locations of the gamma source inside or outside of the well.

5-15 keV 에너지 범위에서 전기증착 선원을 사용한 Si (Li) 검출기 효율결정 (Determination of Si (Li) Detector Efficiency Using Electro-Deposition Sources in 5-15 keV Photon Energy Range)

  • Jeon, Woo-Ju;Park, Tae-Soon;Hwang, Sun-Tae;Joo, Koan-Sik
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.548-554
    • /
    • 1994
  • Si (Li) 검출기의 full-energy peak 효율을 전기증착 선원을 사용하여 실험적으로 결정하였다. 효율 결정에 사용된 측정선원은 $^{51}$ Cr, $^{54}$Mn, $^{57}$ Co, $^{65}$ Zn 핵종으로서 전기증착 방법으로 제작하였으며, 검출기에 collimate를 설치하여 측정하였다. 산출된 효율값은 K X-선에의한 실리콘 결정에서의 탈출확률 및 측정선원과 검출기 사이의 관련 매질에 대한 감쇠효과에 대하여 보정하였으며, 보정된 효율값은 광자 에너지에 무관하게 일정하였다. 결과적으로 5-15 keV 에너지 영역에서 검출효율의 측정 정확도를 향상시킬 수 있었다.

  • PDF

Picosecond Mid-Infrared 3.8 ㎛ MgO:PPLN Optical Parametric Oscillator Laser with High Peak Power

  • Chen, Bing-Yan;Wang, Yu-Heng;Yu, Yong-Ji;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • 제5권2호
    • /
    • pp.186-190
    • /
    • 2021
  • In this study, a compact, picosecond, mid-infrared 3.8 ㎛ MgO:PPLN optical parametric oscillator (OPO) laser output with high peak power is realized using a master oscillator power amplifier (MOPA) 1 ㎛ solid-state laser seeded by a picosecond fiber laser as the pump source. The pump source was a 50 MHz and 10 ps fiber seed source. After AOM pulse selection and two-stage solid-state amplification, a 1,064 nm laser output with a repetition frequency of 1-2 MHz, pulse width of 9.5 ps, and a maximum average power of 20 W was achieved. Furthermore, a compact short cavity with a unsynchronized pump is adopted through the design of an OPO cavity structure. When the injection pump power was 15 W and the repetition frequency was 1 MHz, the average output power of idler light was 1.19 W, and the corresponding peak power was 119 kW. The optical conversion efficiency was 7.93%. When the repetition frequency was increased to 2 MHz, the average output power of idler light was 1.63 W, the corresponding peak power was 81.5 kW, and the optical conversion efficiency was 10.87%. At the same time, the output wavelength was measured at 3,806 nm, and the beam quality was MX2 = 3.21 and MY2 = 3.34.

Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성 (A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method)

  • 정종한;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

원격제어 에어컨 개발 보급현황 및 향후전망 (A development of direct load control system for air-conditioner)

  • 강원구;김충환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF