• 제목/요약/키워드: pattern scanner

검색결과 119건 처리시간 0.026초

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가 (Accuracy evaluation of dental model scanner according to occlusal attrition type)

  • 김동연;김지환;이범일;이주희;김원수;박진영
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

스캐너와 평균 밝기를 이용한 프린터 출력물의 색 균일도 추정 (Color Uniformity Estimation of Printouts Using a Scanner and Average Brightness)

  • 김지홍;최두현
    • 한국멀티미디어학회논문지
    • /
    • 제12권7호
    • /
    • pp.1016-1021
    • /
    • 2009
  • 컬러 프린터의 성능을 결정하는 여러 요소 중 색 균일도는 프린터의 개발 단계에서나 완제품의 성능 평가 지표로 중요한 항목이다. 개발 현장에서는 현재 농도계를 사용하여 수동으로 색 균일도를 측정하고 그 측정 결과를 분석하여 성능을 평가한다. 본 논문에서는 스캐너와 평균 밝기를 사용하여 색 균일도를 자동으로 추정하는 방법을 제안한다. 제안된 방법은 기존의 방법에서 사용하는 패턴과 스캐너를 이용하여, 위치에 따른 색 균일도를 추정하며, 실험을 통해 추정된 데이터가 농도계로부터 측정된 농도와 유사함을 보인다. 아울러 균일도에 대한 분석과 함께 현재 판매되고 여는 프린터와 스캐너를 이용하여 제안한 알고리즘의 유용성을 검증한다.

  • PDF

3D모델을 이용한 비만체형 여성의 허리-배 부위 패턴 특성 연구 (Pattern Development of Waist / Abdominal Area of Obese Womem Using 3D Geometrical Model)

  • 김소영;홍경희
    • 한국의류학회지
    • /
    • 제29권7호
    • /
    • pp.1018-1026
    • /
    • 2005
  • Recent development of 3D scanner and software is regarded as a promising method of acquiring replicas from human body indirectly. It would be very helpful if we could predict the characteristics of 2D pattern from the simple parameters related to 3D shape for ordinary user. Therefore, in this study, investigation of 2D pattern of waist/abdominal area from the 3D geometrical model was conducted for the pattern development of waist nipper. To create body models and develop the surface of them, one ortho commonly used CAD/CAM program, IDEAS(UGS-plm solutions, USA) was used. As for the size of the models, the width, thickness, and circumference ranges of adult women's torso reported in National Anthropometric Survey of Korea (1997) were used as a standard model. Seven size variations were made by changing the width of the waist only, from 19 cm to 40 cm. Therefore, simulated body models include not only the normal body but also obese body who has wider waist and abdomen width than hip width. As results, it was found that the curvature of the unfolded 2D pattern around the abdominal area decreases as the waist width increases. As the width of the waist increases more and more, so that the comparative ratios around the torso becomes in abnormal ranges, there appears inflection points and the direction of curvature was changed. 2D Patterns obtained in this research were quantified by curvature, length of the curve and angle of deflection in the reference frame box for the convenience of the actual pattern making process. It was also possible to find that the shape of patterns of abnormal body resulted in a quite interesting change in the curves of 2D pattern, which could be applied to the custom made waist nipper for obese women.

노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구 (Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women)

  • 서추연;박순지
    • 한국의류학회지
    • /
    • 제32권5호
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.

일부 한국인 하악 제2소구치 교두 변이 양상에 대한 3차원적 분석 (Three-dimensional analysis of the cusp variation patterns of mandibular second premolar in Koreans)

  • 남신은
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.220-227
    • /
    • 2020
  • Purpose: This study aims to investigate the cusp variation pattern of the Korean mandibular second premolar and to determine the difference in tooth diameter and surface area using a virtual three-dimensional model. Methods: Dental casts from 69 students were scanned as a virtual dental models with a three-dimensional dental model scanner. Tooth diameter, absolute and relative individual areas, total crown area, the number of lingual cusps and central groove pattern were analyzed using RapidForm 2004. The Mann-Whitney U-test and the Kruskal-Wallis test were performed to verify sexual dimorphism, the difference in tooth diameter and surface according to the cusp variation pattern (α=0.05). Results: There was no significant difference except in buccolingual diameter (p<0.05) and buccolingual diameter at the cervix (p<0.05). The relative surface area of the total clinical crown was 65.76% for the buccal half and 34.24% for the lingual half, with a ratio of 2:1. In the case of the presence of two lingual cusps, the ratio was 21.47% for the mesiolingual half and 14.12% for the distaolingual half, with a ratio of 3:2. The dominant central groove patterns of the second premolar were the H-pattern (42.0%), followed by the Y-pattern (37.7%), then the U-pattern (20.3%). The relative buccal half was largest in the U-pattern central groove and the relative lingual half was largest in the Y-pattern central groove (p<0.05). Conclusion: This study is significant in that it measured quantitative surface areas and the findings could be a meaningful reference to comprehend dental anatomy in Koreans.

LCD와 가시광선 LED를 사용한 전사방식의 Scanbeam-SLA 개발 (Development of Projection Scanbeam-SLA using Liquid Crystal Display and Visible Light Emitting Diode)

  • 윤수현;박인백;김민섭;조광호;이석희
    • 한국정밀공학회지
    • /
    • 제30권3호
    • /
    • pp.340-348
    • /
    • 2013
  • In Projection Stereolithography Apparatus (PSLA), Digital Micromirror Device (DMD) and Liquid Crystal Display (LCD) are used as a beam pattern generator. The DMD shows high resolution, but it is mostly applied in micro stereolithography due to high cost and fabricable area. In LCD, the size of pattern beam is freely controlled due to various panel sizes. The LCD, however, has some limitations such as short life time by the high power light source, non-uniform light intensity of pattern beam and low transmittance of UV-light. To solve these problems in LCD-based PSLA, a Scanbeam-SLA with LCD of 19 inches and visible LED-array is developed. In this system, the light module works like a scanner for uniform illumination. The system configuration, working principle and fabrication examples are addressed in this study.

3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석 (A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties)

  • 손부현;홍경희
    • 한국생활과학회지
    • /
    • 제18권3호
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

Three dimensional deformation of dry-stored complete denture base at room temperature

  • Lim, Seo-Ryeon;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.296-303
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program. MATERIALS AND METHODS. A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at $1^{st}$ day after deflasking, $14^{th}$ day after deflasking, and $28^{th}$ day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (${\alpha}$=.05). RESULTS. When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found. CONCLUSION. It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern.

동작시 3D 정보를 이용한 2D 패턴 전개 및 신축성 원단의 신장률을 고려한 사이클 팬츠 개발 (Development of 2D Patterns for Cycling Pants using 3D Data of Human Movement and Stretch Fabric)

  • 정연희;홍경희
    • 한국생활과학회지
    • /
    • 제19권3호
    • /
    • pp.555-563
    • /
    • 2010
  • With recent advances in 3D scanning technology, three-dimensional (3D) patternmaking is becoming a powerful way to develop garments pattern. This technology is now applicable to the made to measure (MTM) system of both ordinary and tightly fitting garments. Although the pattern of fitted clothing has been developed using 3D human data, it is still interesting to develop cycling pants by considering while-cycling body posture and fabric elasticity. This study adopted the Garland's triangle simplification method in order to simplify data without distorting the original 3D scan. Next, the Runge-Kutta method (2C-AN program) was used to develop a 2D pattern from the triangular pixels in the 3D scanned data. The 3D scanned data of four male, university students aged from 21 to 25, was obtained using Whole body scanner (Model WB4, Cyberware, Inc., USA). Results showed the average error of measurement was $4.58cm^2$ (0.19%) for area and 0~0.61cm for the length between the 3D body scanned data and the 2D developed pattern data. This is an acceptable range of error for garment manufacture. Additionally, the 2D pattern developed, based on the 3D body scanned data, did not need ease for comfort or ease of movement when cycling. This study thus provides insights into how garment patterns may be developed for ergonomic comfort in certain special environments.