• Title/Summary/Keyword: patients safety

Search Result 2,411, Processing Time 0.025 seconds

Efficacy and Safety during the Combination Therapy of Imipramine and Desmopressin in Primary Monosymptomatic Nocturnal Enuresis (어린이의 일차성 단일 증상성 야뇨증에서 Imipramine과 Desmopressin 복합 약물치료의 효과 및 안전성)

  • Yeo Ji-Hyun;Choi Jung-Youn;Chung Hyo-Seok;Lee Kyung-Soo;Ko Cheol-Woo;Kim Kyo-Sun;Kim Kee-Hyuk;Kim Jung-Soe;NamGoong Mee-Kyung;Park Young-Seo;Pai Ki-Soo;Yoo Kee-Hwan;Park Yong-Hoon
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.129-137
    • /
    • 2004
  • Purpose : Nocternal enuresis is a common disorder. Tricyclic antidepressant and desmopressin have been accepted pharmacological treatment for this disorder We conducted a cooperative study to investigate the efficacy and adverse reactions of imipramine, desmopressin and combination treatment in children with primary monosymptomatic nocturnal enuresis(PMNE). Methods: Data from a large multicenter study were analysed. In the period of 8 months in 2002, the study comprised of 168 children(78 boys and 90 girls, 5 to 15 years old) with PMNE for imipramine, desmopressin or combination treatment. Before treatment a history, physical examination and laboratory tests were performed and the children were observed for 2 weeks. Response rate, adverse reactions and enuresis episodes after stopping drug administration were evaluated after 12-weeks of imipramine, desmopressin or combination of both. Results: After 4 weeks, the frequency of bed wetting in all treated patients decreased during treatment significantly Even though a 30-50%, reduction in the number of wet nights were 68.6%, 74.4% and 86.1% during 12 weeks treatment by imipramine, desmopressin and both of them respectively, there was no significant difference between them. The most common adverse reaction was decreased appetite from imipramine administration. But no serious drug-related adverse events were reported. Conclusion: Efficacy of the combination therapy of imipramine and desmopressin in PMNE appears not to be better than either drug alone. It is necessary to pay attention on account of adverse reactions during imipramine treatment even though imipramine and desmopressin were generally well tolerated.

  • PDF

Comparison of hypertonic saline treatment in meningitis with cerebral edema (뇌수막염에서 발생한 뇌부종 치료에서 고장성 식염수 비교)

  • Kim, Hyung Su;Kim, Hee Ra
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1275-1281
    • /
    • 2006
  • Purpose : Cerebral edema in meningitis is a potentially complication. Hypertonic saline of various concentrations are frequently used to treat cerebral edemas in meningitis. We analyzed the safety and efficacy of osmotic therapy in cerebral edema by comparison of various hypertonic saline concentrations and mannitol. Methods : The medical records of 42 patients, who were followed up in the Department of Pediatrics, Busan Medical Center, from Jan. 2002 to Oct. 2005, were analyzed retrospectively. We measured intracranial pressure, mean flow velocity, and various laboratory parameters. Results : In cerebral edema developed in meningitis, intracranial pressure and symptoms were improved in treatment of hypertonic saline and mannitol. Serial bolus infusion of 3 percent hypertonic saline resulted in the best outcome. There was not a statistically considerable difference on the mean values of the intracranial pressure gap. On transcranial doppler, mean flow velocity was increased and pulsatilty index was decreased. Laboratory findings (osmolarity, Na, Cl, pH, lactic acid, Ca) were diffenent during the treatment period as opposed to K, Hb, bicarbonate, base excess. There was not a specific form of hypertonic saline used in meningitis treatment with cerebral edema. Conclusion : The therapy for cerebral edema in meningitis remains largely empirical. Serial bolus infusion of 3 percent hypertonic saline is better than other hypertonic salines. Various concentrations and different infusion methods of hypertonic saline statistically does not influence the result of treatment. More research aimed at improving cerebral edema treatment is needed to identify new, effective forms of treatment.

Review of 2014 Major Medical Decisions (2014년 주요 의료판결 분석)

  • Jeong, Hye Seung;Lee, Dong Pil;Yoo, Hyun Jung;Lee, Jung Sun
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.1
    • /
    • pp.155-190
    • /
    • 2015
  • The court sentenced meaningful decisions related to the medical service in 2014. The court assumed the negligence of medical staff in the accident if being broken while using the medical equipment for not an original purpose at the time of surgery and ruled that the compensation for damage can be recognized in recognition of the causal relationship between the explanation duty violation and side effect's happening when unproven surgery on safety is implemented regarding the duty of explanation, that in the case of cosmetic surgery, the subject on the duty of explanation needs to be expanded compared to the general medical practice and that the duty of explanation cannot be accepted for the range that cannot be expectable. Also, the court has provided the requirement and limitation of self-determination exercise in case of the crash between patient's self-determination and doctor's duty of care and has ruled that as automobile insurance contract is a contract with the insurance company to pay regarding liability for car accidents, treating patients and taking the insurance money is not illegal activity even for the unlicensed hospital violating the medical law while established. The judgment stating the opinion that medical practitioners cannot be punished according to the medical law prohibiting the receiving of rebate in case that medical practitioners did not receive benefit while the medical institution itself gained an unfair economic benefit also stands out. And the court has ruled that even if the medical institution who received a business suspension is closed, the suspension is still effective in case that the same operator opens a new medical institution in the same place, ruled on the requirement to conduct a medical service outside of the medical institution that the doctor opened and ruled that the administrative penalty cannot be conducted prior to the conviction on charge of violating the medical law.

  • PDF

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

Video Assisted Thoracic Surgery(VATS) of Pericardial Window Operation (비디오 흉강경을 이용한 심낭막 개창술)

  • 윤석원;김동관;김정원;박창률;김용희;박기성;박승일
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.812-816
    • /
    • 2002
  • Pericardial effusions result from various conditions such as inflammation, malignancies, open heart surgery and uremia. Recently, video assisted thoracic surgery (VATS) has been used for diagnostic and therapeutic purposes in the management of pericardial effusion and intrathoracic lesions due to its ability to provide outstanding visibility of intrathoracic structures with less pain, superior cosmetic effects, and shorter hospital stay Material and Method: From April 1995 to October 2001, 51 patients received pericardial window operation via either thoracoscopic(Group A, n=37, m:f=18:19, mean age=56.4 yrs)or thoracotomy approach(Group B, n=14, m:f=8:6, mean age=58.4 yrs). Result: In group A, the operation time, duration of chest tube insertion, recurrence rate of pericardial effusion, and postoperative hospital stay were 61.2 minutes, 9.3 days, 2.7%, 16.2 days, respectively while in group B these values were 58.4 minutes, 12.2 days, 7.1, and 17.3 days. The number of injections for pain control in group A were 4.2 times, whereas in group B it was 6.3 times. Although there was a tendency for the mean hospital stay and duration of chest tube insertion to be shorter in group A than in group B, these differences did not reach statistical significance. There was also no significant difference in the operation time and recurrence rate between the two groups. Conclusion: The safety and effectiveness of VATS in the management of pericardial effusion is comparable to the open thoracotomy method. It allows for a shorter hospital stay, duration of chest tube insertion, lesser postoperative pain and a smaller skin incision.

The Study on U.S. GARA and Aircraft Products Liability (일반항공에서의 제조물책임에 관한 연구 - 미국 일반항공진흥법(GARA)을 중심으로 -)

  • Lee, Chang-Jae
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.29 no.2
    • /
    • pp.55-86
    • /
    • 2014
  • The U.S. General Aviation Revitalization Act of 1994 (the "GARA") created a statute of repose that bars any claims arising from an aviation product or component more than 18 years after its date of delivery. The statute was enacted to protect general aviation aircraft manufacturers from the excessive product liability costs. The GARA included four exceptions: (a) medical emergency patients, (b) those not on the aircraft, (c) those based on written warranties, and (d) those causally related to a "knowing misrepresentation" made by the manufacturer to the FAA. The GARA also incorporates a provision for revised starting point of reckoning to which any repairs or replacements of an aviation product. This note aimed to discuss General Aviation and GARA in depth including the meaning of statue of repose, its exceptions. The various precedents about GARA were also reviewed in here as well. From the GARA, as a comparative legal issue in aviation product liability, there can be some suggestions for revision of Korean Products Liability Act. First, it seems to be reasonable to regulate the specific statute of repose provisions for various category of products. In GARA, the period of 18 years is reasonable concerning to the average aircraft life. Second, in order to avoid exhausting debate and for the judicial economy, it needs to clarify when the statute begins to run. GARA's 18 year limitation period begins to run on the different date whether it was delivered to its first purchaser or a person engaged in the business of selling the aircraft. Last but not least, proper exceptions should be added into the law for equity matter of the statute of repose does not apply. For example, a manufacturer is not protected by GARA if it knowingly misrepresents certain safety information to the FAA.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

A Survey of the Basic Protection Manners of Dental Personnels Against Hepatitis B in and around Seoul (수도권 치과의료 종사자들의 B형 간염에 대한 기초방호실태 및 수행에 관한 조사)

  • Yoon, Mi-Sook;Park, Mi-Young
    • Journal of dental hygiene science
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 2001
  • The purpose of this study was to examine dental personnels' concern for health, their personal protection manner, and whether or not they were inoculated against hepatitis B and made an inquiry of patients about that. It's ultimately meant to serve as a basis for the preparation of an anti-infection guide for the protection of dental personnels against all sorts of infectious diseases. After a survey was conducted from March 29 through May 9, 2001, the following findings were obtained: (1) The dental personnel group that had worked for 5 to less than 7 years took health examination the most, with 71.4%, before joining the hospital, and 61.5% of those who had served for 9 years or more, the greatest percentage, took medical checkup after joining the hospital(P<0.05). (2) The largest percentage of being inoculated against the anti-B type hepatitis after employment was 71.4% of the dental personnels over 35, and 57.7% of those with 9-year or more working experiences. Therefore, their age and service term made a significant difference(P<0.05). (3) There was no significant gap in personal protection practices between the dental hygienists and nurse aids(P>0.05). But the use of safety goggles for treatment was not properly done, with just 1.48 on the basis of 3 points, whereas the use of mask was scored 2.40 and the use of gloves was scored 1.96. (4) After a narcotic was used once, the leftovers were wasted by 89.7% of the dental hygienists and 70.0% of the nurse aids. More dental hygienists wasted them(P<0.05). (5) For hand washing, antibiotic liquid soap was used by 19.3% of the dental hygienists and 10.0% of the nurse aids, which were both very low percentage. And just 37.2% of the dental hygienists utilized a disposable paper towel to dry their hands, and only 36.0% of the nurse aids used the same(P<0.05).

  • PDF

Factors Influencing Infection Control Awareness and Implementation Levels among Dental Hygienists (치과위생사의 감염관리 인지도와 실천도에 영향을 미치는 요인)

  • Jang, Kyeung-Ae;Park, Jung-Hyun
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.183-192
    • /
    • 2016
  • A total of 228 dental hygienists working in dental hospitals and clinics in the Busan and Gyeongnam areas were surveyed between August 1, 2015, and October 15, 2015. The factors influencing infection control awareness and implementation levels among the dental hygienists were investigated to prepare basic data with the goal of establishing guidelines for systemic infection control. Treatment preparation support for infection control positively correlated with equipment and facility support (r=0.4343, p<0.01), treatment skill and information support (r=0.231, p<0.01), infection control education support (r=0.266, p<0.01), infection control awareness (r=0.354, p<0.01), and infection control implementation levels (r=0.442, p<0.01). Equipment and facility support positively correlated with treatment skill and information support (r=0.418, p<0.01), infection control education support (r=0.422, p<0.01), infection control awareness (r=0.404, p<0.01), and infection control implementation levels (r=0.454, p<0.01). Infection control education support positively correlated with infection control awareness (r=0.348, p<0.01) and infection control implementation levels (r=0.405, p<0.01). Infection control awareness positively correlated with the infection control implementation level (r=0.879, p<0.01). The factors influencing the awareness of infection control include treatment preparation support, equipment and facility support, treatment skill and information support, and infection control education support. The influencing the infection control implementation level include treatment preparation support, equipment and facility support, infection control education support, and treatment skill and information support. To enhance the awareness of infection control and implementation levels amongdental hygienists, an infection control system must be established and implemented A rigorous system for evaluating dental clinics must also be established to ensure an ideal dental treatment environment and to protect patients' health and safety.