• 제목/요약/키워드: patient variation

검색결과 356건 처리시간 0.026초

$^{99m}Tc$ Pertechnetate를 사용(使用)한 뇌(腦)스캐닝 (Technetium 99m Pertechnetate Brain Scanning)

  • 이상민;박진영;이안기;정주일;홍창기;이종헌;고창순
    • 대한핵의학회지
    • /
    • 제2권1호
    • /
    • pp.59-66
    • /
    • 1968
  • Technetium 99m pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and I case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed "hot areas." Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with $^{203}Hg$-Neohydrin or $^{131}I$-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced $^{99m}Tc$ to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  • PDF

Anatomical Variation of the Lesser Saphenous Vein

  • Hwang, So-Min;Pan, Hao-Ching;Kim, Hong-Il;Jung, Yong-Hui;Kim, Hyung-Do
    • Archives of Reconstructive Microsurgery
    • /
    • 제22권2호
    • /
    • pp.48-51
    • /
    • 2013
  • Purpose: The lessor saphenous vein is an anatomical index in various surgical methods involving an approach to the popliteal fossa. However, occasionally, there have been some cases where the surgical process was difficult because the lessor saphenous vein was not found in the popliteal fossa during the operation process. The aim of this study is to determine the frequency of the anatomical variation of lessor saphenous vein not found in the popliteal fossa with a review of the literature. Materials and Methods: This study was conducted on 83 cases of selective neurectomy for hypertrophic calf performed in our clinic from March 1997 to June 2013. There were 42 patients, with a mean age of 32.8 years old. We confirmed the existence of the lessor saphenous vein in the popliteal fossa during the operation process. Results: Among 83 cases during this study period, the lesser saphenous vein was not found in four cases. In one patient, no lesser saphenous vein was found on either side of the popliteal fossa, and in two patients, no lesser saphenous vein was found on the left side of the popliteal fossa. As a result, the frequency of variation was found to be 4.8%. Conclusion: Due to the anatomical variation of the lessor saphenous vein, it may not be found in the midline of the popliteal fossa. Based on the literature review, several possibilities for failure to observe the lesser saphenous vein could be suggested. If surgeons are well aware of these possibilities, the steadier operation could be performed.

  • PDF

요양병원 환자분류체계 개발 (Development of Patient Classification System in Long-term Care Hospitals)

  • 이지윤;윤주영;김정회;송성희;주지수;김은경
    • 간호행정학회지
    • /
    • 제14권3호
    • /
    • pp.229-240
    • /
    • 2008
  • Purpose: To develop the patient classification system based on the resource utilization for reimbursement of long-term care hospitals in Korea. Method: Health Insurance Review & Assessment Service (HIRA) conducted a survey in July 2006 that included 2,899 patients from 35 long-term care hospitals. To calculate resource utilization, we measured care time of direct care staff (physicians, nursing personnel, physical and occupational therapists, social workers). The survey of patient characteristics included ADL, cognitive and behavioral status, diseases and treatments. Major category criteria was developed by modified delphi method from 9 experts. Each category was divided into 2-3 groups by ADL using tree regression. Relative resource use was expressed as a case mix index (CMI) calculated as a proportion of mean resource use. Result: This patient classification system composed of 6 major categories (ultra high medical care, high medical care, medium medical care, behavioral problem, impaired cognition and reduced physical function) and 11 subgroups by ADL score. The differences of CMI between groups were statistically significant (p<.0001). Homogeneity of groups was examined by total coefficient of variation (CV) of CMI. The range of CV was 29.68-40.77%. Conclusions: This patient classification system is feasible for reimbursement of long-term care hospitals.

  • PDF

전국 종합병원 의료인력의 생산성분석 (An Analysis of the Physician Productivity in General Hospitals)

  • 이정운;이기효;문옥륜
    • Journal of Preventive Medicine and Public Health
    • /
    • 제24권3호
    • /
    • pp.400-413
    • /
    • 1991
  • The purpose of this paper is to identify factors affecting the optimum mix of required inputs and other relevant factors which account for the variation in physician's productivity in general hospitals, and to find out their implications for the efficient health planning and management. An extended version of Cobb-Douglas production function and cross sectional data of one day patient census from all general hospitals in Korea in 1988 were used in the analysis. Main results of the analysis and their implications could be summarized as follows : (1) The production function for physician's inpatient service shows the evidence of economies of scale, but the production function for physician's outpatient and adjusted-patient service, which combines both out- and in-patient service, shows that of dis-economies of scale. (2) The physician's role for production for all service is smaller than auxiliary personnel's, which imply that more intensive utilization of nurses, nursing aides and other auxiliary personnel is desirable for improving general hospital productivity (3) In case of physician's inpatient and adjusted-patient service, nurses' role is greater than nursing aides'. Therefore, more extensive utilization of nurses is recommended for the efficient operation of general hospitals. (4) The factor of hospital beds plays the leading role among required inputs in the production for physician's in- and adjusted-patient service. (5) The physician's productivity of general hospitals in rural area is lower than that in urban area. And the productivity of teaching hospitals is lower than that of the other hospitals. Further analysis was made in physician production function based upon the size of hospitals, namely those hospitals below 250 beds and those above. Explained variances by the factor of hospital beds was significantly increased in the case of those hospitals above 250. A more detailed and thorough investigation is needed for verifying factors influencing physician's productivity in general hospitals in Korea.

  • PDF

마취 심도 측정을 위한 뇌파 계측의 유용성 평가 (Usefulness Evaluation of measuring EEG for the Anesthetic Depth Monitoring)

  • 김재현;박준모;천상오;예수영;정도운;백승완;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.289-292
    • /
    • 2002
  • In this study, we measure and analyzed variation of EEG signal by anesthesiologist progress step. In an experiment, the EEG signal was acquired and analyzed as 5 steps(prior surgical operation, during induction, surgical operation, awakening, posterior surgical operation). As a result, we confirm the anesthesiologist progress phase, concluded the possibility of anesthesia depth because using SEF and MF, and Delta ratio confirmed that can presume operating patient's consciousness state.

  • PDF

환자만족도 조사설문지의 설문문항 배열에 따른 신뢰도 분석 (The Reliability of Satisfaction Questionnaire According to Item Arrangement)

  • 최귀선;조우현;홍재석;이선희;강명근
    • 한국의료질향상학회지
    • /
    • 제7권2호
    • /
    • pp.180-188
    • /
    • 2000
  • Objectives : The purpose of this study was to evaluate the reliability of questionnaire according to item arrangement on patient satisfaction questionnaire. Methods : We developed the two types of questionnaire with different item arrangement. In the first type (A), questions were arranged according to medical service dimensions. Questions in the second type (B) were arranged according to medical process. Both questionnaires were composed of six dimensions: physical environments, process, competence, courtesy, information giving, understanding patients. Measurements were performed on a 5-score Likert scale. In an outpatients and inpatient survey, total 777 patients answered the type A (outpatients: 257, inpatients: 128) or Type B (outpatients: 257, inpatients: 135). In order to compare the internal consistency of two types. Cronbach's ${\alpha}$ were calculated. Multiple regression analysis was also performed to know which type of questionnaire explain more of the overall satisfaction. Results : In outpatient survey, type A questionnaire showed higher internal consistency than B except physical environments dimension. Also in inpatient survey, type A had higer internal consistency than B in four dimensions(process, competence, courtesy, understanding patients). In the results of multiple regression analysis, type A questionnaire ($R^2$=0.53) explained more of the variation in overall satisfaction then B questionnaire ($R^2$=0.43) in outpatient survey. In inpatient survey, type B questionnaire ($R^2$=0.40) explained, more of the variation in overall satisfaction than type A questionnaire ($R^2$=0.33).But the difference of R was not significant in inpatient survey. Conclusion : The results of this study support that type A questionnaire has higer reliability in assessment of consumer satisfaction than type B.

  • PDF

우리나라 성인 2형 당뇨환자에서의 외래 투약 순응도와 관련요인 분석 (Oral Antihyperglycemic Medication Adherence and Its Associated Factors among Ambulatory Care with Adult Type 2 Diabetes Patients in Korea)

  • 홍재석;강희정
    • 보건행정학회지
    • /
    • 제20권2호
    • /
    • pp.128-143
    • /
    • 2010
  • Objectives : This study aims to estimate the oral antihyperglycemic medications adherence among ambulatory care with adult type 2 diabetes patients and to identify factors affecting the medication adherence in Korea. Methods : This study used the Korean National Health Insurance Database. Study population was 40,082 patients who were 20 years of age or older and first diagnosed with type 2 diabetes (ICD-10: E11) in 2004. The patients were followed up for two years in order to measure adherence with oral antihyperglycemic medications. The level of medication adherence was measured by the medication possession ratio (MPR). Results : The average MPR in the study population was 49.5%. The appropriate adherence rate (MPR$\geq$80%) was 29.4% and showed variation according to the characteristics of individual patients. Multiple logistic regression analysis revealed that the odds of appropriate adherence increased with female (OR:1.21, CI:1.14-1.27), older age, increasing ambulatory care visits, health insurance (OR:1.53, CI:1.33-1.76), decreasing ambulatory care providers, using a specialized general hospital as their main attending medical institution (OR:10.08, CI:8.96-11.33), having co-morbidity, using polytherapy (OR:1.07, CI:1.01-1.13). Conclusions : The medications adherence for patient with type 2 diabetes is low in Korea, and shows variation according to the characteristics of patients. For proper management of diabetes, health care policy is expected to be enacted to improve medications adherence continuously. In particular, more intensive management is needed for patients with low medications adherence. Also, health care policy makers need to develop the program to induce health care utilization by a patient to be more concentrated with the same provider.

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

Factors associated with treatment outcomes of patients hospitalized with severe maxillofacial infections at a tertiary center

  • Kim, Hye-Won;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권3호
    • /
    • pp.197-208
    • /
    • 2021
  • Objectives: The purpose of this retrospective study was to evaluate the variables associated with length of stay (LOS), hospital costs, intensive care unit (ICU) use, and treatment outcomes in patients hospitalized for maxillofacial infections at a tertiary medical center in South Korea. Materials and Methods: A retrospective chart review was conducted for patients admitted for treatment of maxillofacial infections at Dankook University Hospital from January 1, 2011 through September 30, 2020. A total of 390 patient charts were reviewed and included in the final statistical analyses. Results: Average LOS and hospital bill per patient of this study was 11.47 days, and ₩4,710,017.25 ($4,216.67), respectively. Of the 390 subjects, 97.3% were discharged routinely following complete recovery, 1.0% expired following treatment, and 0.8% were transferred to another hospital. In multivariate linear regression analyses to determine variables associated with LOS, admission year, infection side, Flynn score, deep neck infection, cardiovascular disease, admission C-reactive protein (CRP) and glucose levels, number and length of surgical interventions, tracheostomy, time elapsed from admission to first surgery, and length of ICU stay accounted for 85.8% of the variation. With regard to the total hospital bill, significantly associated variables were age, type of insurance, Flynn score, number of comorbidities, admission CRP, white blood cell, and glucose levels, admission temperature, peak temperature, surgical intervention, the length, type, and location of surgery, tracheostomy, time elapsed from admission to first surgery, and length of ICU use, which accounted for 90.4% of the variation. Age and ICU use were the only variables significantly associated with unfavorable discharge outcomes in multivariate logistic regression analysis. Conclusion: For successful and cost-effective management of maxillofacial infections, clinicians to be vigilant about the decision to admit patients with maxillofacial infections, perform appropriate surgery at an adequate time, and admit them to the ICU.

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.