• 제목/요약/키워드: patient recognition

검색결과 421건 처리시간 0.032초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

부정교합의 객관적 정량분석: Part 2. 부정교합 요소들의 치료난이도에 미치는 영향 (The objective and quantitative analysis of malocclusion - Part 2. Influence of malocclusion components to treatment difficulty)

  • 주보훈;이기수
    • 대한치과교정학회지
    • /
    • 제35권1호
    • /
    • pp.69-81
    • /
    • 2005
  • 부정교합의 진단과 치료계획 수립 및 치료방법에서 술자 간의 차이, 교정치료에서 환자간의 수용차이를 보이는 것은 부정교합의 인식 정도가 다양하기 때문이다 정부 및 민간 기관에서 보건정책의 계획과 집행은 체계적으로 진행된 과학적인 연구자료를 기초로 이루어져야 한다. 이 연구는 부정교합의 객관적 정량분석을 위한 마지막 단계로써 객관적인 부정교합의 경중도 (objective malocclusion severity) 와 주관적인 치료의 난이도 (subjective treatment difficulty)의 상관관계를 연구한 결과를 토대로 주관적인 치료의 난이도에 미치는 부정교합 구성요소의 영향을 평가한 후 치료의 난이도를 반영하는 부정교합 구성요소들의 가중치를 도출하고자 하였다. 이를 위하여 , 치아모형 100쌍을 이용하여 경험 있는 치과교정의 8명이 주관적으로 측정한 치료의 난이도와 동료 평가등급 지수를 사용하여 측정한 객관적인 부정교합의 경중도 간의 상관관계를 연구하고, 각 부정교합의 구성요소별 치료난이도에 미치는 영향을 조사하였다. 1) 이들간의 상관관계의 조사에서 객관적으로 계측한 부정교합의 경중도와 평가단의 치료 예상난이도 사이에는 유의한 관련성이 있었으며 2) 부정교합의 구성요소 별 치료 난이도의 관계를 구명하기 위하여, 주관적으로 느끼는 치료난이도의 인식에 있어 중요한 영향을 미치는 부정교합요소를 산정하였고, 3) 치료난이도를 반영하는 부정교합요소별 가중치를 산출하였다. 산출된 부정교합요소와 그 가중치는 전치돌출도가 5. 정중선일치가 4. 협측교합상태가 3, 전치피개도가 2 그리고 상악전치배열이 1 이었다. 4) 5개의 부정교합 요소와 가중치로 통계적인 검증을 거쳐 치료 난이도를 포함하는 부정교합 경중도의 객관적인 평가가 가능한 한국형 동료판정등급 가중지수를 개발하였다. 부정교합 요소에 대한 국내 치과교정의사들의 인식정도에 의하여 산출된 가중치를 이용한 동료판정등급 지수는 부정교합의 객관적 경중도 평가에 있어 치료의 주관적 난이도를 내포한 유용한 도구로서 국내 공공분야 및 전문분야에서 부정교합 난이도와 경중도의 객관적 그리고 정량적 평가를 가능하게 할 것으로 생각된다.

한국문화에 따른 간호정립을 위한 기초조사연구 III -의료관을 중심으로- (A Study of the Construction of Nursing Theory in Korean Culture - View of Medicine-)

  • 박정숙;오윤정
    • 지역사회간호학회지
    • /
    • 제9권1호
    • /
    • pp.143-162
    • /
    • 1998
  • This is a study for the construction of nursing care based upon the Korean attitude toward medicine. Factors which were investigated include the source of nursing care, the reason for choosing care, the type of heath care chosen, the accessability of caregivers, and the desired location of death. The population examined in this study consisted of 517 adults distributed in six large cities and 191 adults from five rural communities. Data was analyzed using frequency, percent, Cronbach alpha, $X^2$ - test, t - test, F - test and scheffe post hoc contrast with an SAS program. The results of this study are summarized as follows: 1. Among sources of nursing care used, first rank rated-pharmacy(54.4), private hospital(18.2), general hospital(8.4), folk remedies in house (5.0), chinese hospital(2.8), prayer(2.8) and others(8.4), and the reasons for choosing nursing care rated 'the easiest method' (63.6), 'the best method'(15.7), 'reliable'(10.8) and 'lower cost burden'(4.6) in order of preference. 2. The type of nursing care chosen rated western medicine(6.80), chinese medicine(6.15), folk remedies(5.46), faith remedies(3.51) and divination remedies (1.41). There were significant differences in the effect recognition degree to various kinds of medicine. 3. The difference of the type of nursing care chosen according to general characteristics showed that urban residents were higher than rural community residents(t=2.15, p=0.0320) in western medicine, and urban residents, women, and singles were higher than rural community residents(t=2.04, p=0.0414), men (t= -2.89, p=0.0039), and married(t=2.50, p= 0.0126) on folk remedies. With repect to age and education those 21-30, under 20 and 31-40, graduated from college and graduate school were higher than above 51, above 61 (F = 7.76, p = 0.0001), graduated from elementary school(F=4.39, p=0.0006) on folk remedies. In other categories, rural community residents, women, younger people. Christians were higher than urban residents ( t = -2.73, p=0.0305), men(t= -4.15, p=0.0001), older people (F=2.48, p=0.0307), Catholic, Buddhist, or atheist (F= 70.18, p=0.0001) on faith remedies. Those graduated from high school and Buddhist were higher than unschooled, graduated from middle school(F=3.18, p= 0.0075), atheist, Catholic or Christian(F=18.32, p=0.0001) on divination redemies. There were significant differences concerning age and education level. 4. The accessibility of caregivers rated 'caregivers should be nearby if the patients need them' (50.0), 'caregivers must be there all day (24 hours)' (39.6), 'caregivers must be there at night only'(5.0), 'caregivers must be there during the day only'(2.6), 'caregivers always should visit during visiting hours' 0.4), 'caregivers don't need to be there at all' (1.2). The frist rank of suitable caregivers were rated as spouse(66.6), mother(24.2), daughter (3.6), daughter-in-law(1.9), and the reasons of thinking thus were rated as 'the most comfortable' (81.5), 'people should correctly with regards to family they'(7.1), 'the easiest' (5.4), 'take good care of the patient' (5.1) and 'lower cost burden' (0.4). 5. The desired location of death rated as the following: his/her house (91. 6) to the hospital(8. 4). A person going to encounter death in the hospital wanted his house(78.5) over the hospital(21.5), and a person dieing in the hospital prefered his house(52.9) over the hospital(47.1) as a funeral ceremony place. The following suggestions are made based on the above results. 1. A sampling method that enhances the re presentativeness should be used in regional and/or national related research and replicated to confirm the result of this study. 2. This study should be used to understand the Korean view of medical centers and to meet the expectations of patients in Korean nursing. 3. Research on the Korean traditional view of humans and expectations of the sick, health and illness, and health behavior, the perception of dying, the decision to heal, and the view of general medicine should continue to be conducted continuosly so that Korean nursing theory can be advanced on these concepts.

  • PDF

일부 치과병원 흡연환자의 구강위생용품 이용도 (Availability of Oral Hygiene Devices for the Patients with Smoking in some Dental Clinics)

  • 장경애;성미경;강현경;최정옥;김윤신
    • 치위생과학회지
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2008
  • 본 연구는 흡연유무에 따른 구강위생용품의 이용도를 파악하여 구강건강을 증진시키고 금연활동지도를 위해 일부 치과병원에 내원한 326명을 대상으로 자기기입식 설문조사를 실시하였다. 수집된 자료는 SPSS 12.0 통계프로그램을 이용하여 다음과 같은 결론를 얻었다. 1. 흡연유무에 있어 사용하는 잇솔의 종류는 '부드러운 잇솔' 이라는 응답은 흡연자에서 64.5%로 높게 나타났고(p < 0.001), 1회 잇솔질 시간은 '3분이상' 이라는 응답은 비흡연자가 61.4%로 높게 나타났다(p < 0.001). 2. 흡연유무에 있어 사용하는 구강위생용품의 종류는 비흡연자는 36.7%로 흡연자보다 치간잇솔 사용이 더 높게 나타났다. 3. 흡연유무에 있어 구강위생용품을 사용하게 된 동기는 '치과에서 권장해서' 라고 응답한 비흡연자와 흡연자는 각각 69.6%, 67.5%로 비슷하였고, 구강위생용품을 사용하지 않는 이유는 '사용법을 몰라서' 라고 응답한 흡연자는 38.7%로 비흡연자보다 높게 나타났다(p < 0.05). 4. 흡연유무에 있어 구강건강관리방법은 '정기적으로 치과에서 검진한다' 라고 응답 한 흡연자는 28.3%이었고, 비흡연자는 35.3%로 비흡연자가 약간 높게 나타났다. 본 연구의 결과, 흡연의 유무에 따른 구강위생용품의 이용도와 인지는 흡연자가 낮았으며, 유의한 차이를 보였다. 따라서 전국민을 대상으로 구강위생용품의 효과 및 필요성에 대한 홍보가 적극적으로 이루어지고, 치과의료기관에서는 구강구강보건 전문인력인 치과위생사는 흡연유무에 있어 구강의 특성을 파악하여 적합한 구강위생용품의 선택과 사용방법에 대한 교육과 금연지도활동이 치과에서 확대실시 될 수 있도록 노력하여야 할 것이다.

  • PDF

말기암환자에서 임박사건 간 48시간 임종예측도 비교 (Predictability of Impending Events for Death within 48 Hours in Terminal Cancer Patients)

  • 황인철;최충현;김경곤;이경식;서희선;심재용
    • Journal of Hospice and Palliative Care
    • /
    • 제14권1호
    • /
    • pp.28-33
    • /
    • 2011
  • 목적: 임박사건(impending event)에 대한 인지는 보호자와의 보다 효과적인 의사소통을 위해 필요할 뿐 아니라, 임종실로 옮기는 시점을 결정하는데 있어서 매우 중요하다. 이 주제에 대한 지금까지의 연구는 대부분 임종 48시간을 전후한 시점에서 이미 '발생되어 있는' 증상의 나열에 불과하였다. 이에 '변화'의 시점에서 사망까지의 시간을 기준으로 하여 임박사건 간 48시간 이내 임종예측도를 비교하였다. 방법: 인천소재 완화의료병동에서 임종을 맞이한 160명의 환자 중 임종 전 일주일 동안의 의무기록이 있는 80명을 대상으로 하였다. 환자 및 보호자가 호소하는 주관적 증상 9가지와 의료인에 의해 관찰되는 객관적 징후 8가지를 선정하고 각 항목에 대한 '의미 있는 변화'의 기준을 사전에 정하였다. 결과: 증상에서는 수면량의 증가(53.8%), 징후에서는 혈압의 감소(87.5%)가 가장 높은 발생빈도를 보였다. 임종까지의 평균시간은 증상의 경우 안정 시 호흡곤란(46.8시간)이, 징후의 경우 산소포화도의 감소(13.6시간)와 혈압의 감소(36.9시간)가 48시간 이내였다. 48시간 임박사건으로서의 예측도는 증상의 경우, 양성예측도는 안정 시 호흡곤란이 가장 높았고(83%) 음성예측도는 안정 시 호흡곤란과 의식혼탁/섬망의 조합이 가장 높았으며(86%), 징후의 경우 양성 예측도는 모두 95% 이상이었고 음성예측도는 혈압의 감소와 산소포화도 감소의 조합에서 가장 높았다(60%). 증상과 징후의 발생양상은 유의한 차이를 보였다. 결론: 증상에서는 안정 시 호흡곤란과 의식혼탁/섬망이, 징후에서는 산소포화도나 혈압의 감소가 임종임박을 예측하는데 가장 유용한 임상지표로 생각된다.

대전 동구 보육원생의 구강건강 및 구강건강관련 삶의 질 (Oral Health and Quality of Life of the Orphans in Dong-gu, Daejeon)

  • 궁화수;송은주;황수정
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.223-229
    • /
    • 2013
  • 본 연구는 대전 동구 보육원생 대상 계속구강건강관리사업의 효과를 평가하고자 대전 동구 보육원생 109명을 대상으로 하여 2012년 7~8월에 구강검사와 COHIP를 비롯한 설문조사를 실시하였다. 2010년 국민구강건강실태조사 대전시 표본과 대전 동구에 거주하고 보건소 계속구강건강 관리사업을 받지 않은 아동의 자료를 검정값으로 이용하여 일표본 검정을 하였으며, 연구 결과는 다음과 같다. 1. 계속구강건강관리사업을 받은 보육원 9~12세 아동과 13~18세 청소년은 우식경험영구치수에 있어서 대전시 12세, 15세 표본과 각각 비교하여 차이가 없으나, 13~18세 청소년은 대전시 15세 표본과 비교하여 우식치아수와 우식치면수가 유의하게 많았다(p<0.001). 2. 계속구강건강관리사업을 받은 보육원 9~12세 아동은 보건소 계속구강건강관리사업을 받지 않은 아동과 비교하여 치면세균막지수는 유의하게 적어서(p<0.001), 잇솔질 방법을 올바르게 수행하고 있는 것으로 판단되었다. 3. 계속구강건강관리사업을 받은 보육원 13~18세 청소년은 대전시 15세 표본과 비교하여 유의하게 적은 잇솔질 횟수, 많은 치은출혈삼분악수를 보여(p<0.001), 연령이 증가하면서 자가구강건강관리가 부족한 것으로 판단되었다. 4. 계속구강건강관리사업을 받은 보육원 9~12세 아동은 보건소 계속구강건강관리사업을 받지 않은 아동과 비교하여 아동 구강건강관련 삶의 질(COHIP) 총점과 자기이미지와 학교환경의 항목에서 부정적이었다(p<0.05). 따라서, 보육원생의 구강건강증진을 위해서는 현재 발생되어 있는 우식치면수의 감소가 필요하므로 구강병예방사업과 더불어 구강병치료사업이 추가되어야 한다. 연령이 증가할수록 구강건강이 악화되는 양상을 나타내므로 청소년은 아동과 분리하여 청소년에 맞는 구강보건교육, 보육원내의 구강보건행동에 대한 지속적인 모니터링과 심리적 지지가 필요하다.

황제내경(黃帝內經)에 보이는 한(汗)관련 서술(敍述)의 특징(特徵)에 대한 고찰(考察) (A Study on the Characteristics of Descriptions of the Perspiration in "Hwangjenaegyeong(黃帝內經)")

  • 유정아;장우창;백유상;정창현
    • 대한한의학원전학회지
    • /
    • 제23권2호
    • /
    • pp.205-223
    • /
    • 2010
  • In Korean Traditional Medicine(abbreviated to K.T.M.), hyperhidrosis and anhidrosis are the targets of the medical treatment. Furthermore sweating appearance is also one of the important symptoms which explain a particular situation of the patient in K.T.M. And at "Sanghanron(傷寒論)" which is a traditional chief clinical bible written by Jang Gi(張機) later Han dynasty(漢代) in China made full use of the various kinds of diaphoresis[汗法] as a main medical treatment with purgation therapy[下法] and emetic therapy[吐法]. So the sweat in itself not only is the disease, but also is one of the symptoms explain a disease pattern. This thesis inquires into "Hwangjenaegyeong(黃帝內經)" referring to sweat which is the origin of recognition to the sweat in K.T.M. Some theses similar to this research had been made progresses and already reported, but most of them have classified the contents into biology, pathology, diagnosis, treatment after the model of western medical theory. In the aspect of comparative studying with other literature and clinic practical using, we found characteristics of referring to sweat in "Hwangjenaegyeong(黃帝內經)". And we classify the characteristics into some categories as follows. 1. There are some terms which make a title including sweat and symbolize the characteristics, for example sweat of soul[魄汗], sweat of death[絶汗], sweat of streaming[灌汗], sweat of weakness[白汗], sweat of sleep[寢汗], sweat of bright and heat[炅汗], sweat of kidney[腎汗], sweat of escaping[漉汗], cold sweat[寒汗], sweat on the head[頭汗], hyperhidrosis[多汗], heavy sweat[大汗]. But there aren't spontaneous sweat[自汗] or sweat like a thief[盜汗] which are the normal terms referring to sweat in history of K.T.M. And there are several descriptions about sweat appearance such as sweating in half of body[汗出偏沮], sweating in the rear end and thigh and knee[汗出尻陰股膝], hyperhidrosis in the neck and aversion to wind[頸多汗惡風], hyperhidrosis in the head and face and aversion to wind[頭面多汗惡風], cannot stopping the sweating under head[頭以下汗出不可止], make a person sweat to one's feet[令汗出至足], sweating like escaping[漯漯然汗出], sweating like soaking[汗出如浴], sweating become moist[汗出溱溱], hardly escaping sweat[汗大泄], escaping sweating[漉漉之汗], sweat moisten the pores [汗濡玄府], ceaseless sweating like pouring[汗注不休] sweating like pouring and vexation[汗注煩心], damp with sweat[汗汗然], sweating spontaneously[汗且自出], removal of fever with sweat drying[熱去汗稀]. That can be divided into sweat region and sweat form. 2. There are detailed explanations of the principle of perspirations caused by hot weather, hot food, hard working and meeting damp pathogen. 3. There are some explanations of the principle of removing fever due to the excessive heat from internal and external body through sweating by replenishing the body fluid. And many descriptions about overcoming the febrile disease by dropping temperature through sweating and many diaphoresis for curing. 4. There are some descriptions about five Jang organs perspirations and attachment of five mucous body fluid to five Jang organs. 5. There are pathogenic progresses after sweating affected by the Six Atmospheric Influences and water. And detailed explanations of disease mechanism a sweat leading to another disease. 6. There are descriptions about various sweat absent situations.

융합적 관점에서 본 병원 사인시스템 다중언어 표기 현황 조사 - 부산 및 경남지역 의료기관을 중심으로 - (A Field Research on Multi-Language Sign System in Hospital at the Point of View in Convergent Study - Focused on General Hospital in Busan and South Gyeongsang Province -)

  • 박한나;백진경
    • 한국과학예술포럼
    • /
    • 제37권1호
    • /
    • pp.87-97
    • /
    • 2019
  • 본 연구는 최근 몇 년간 빠르게 성장하는 국제간의 의료관광 및 외국인 환자 유치의 추세에 따라 국내 의료현황을 파악하고자 하는 것에서 시작하였다. 그 중, 국내 수도인 서울에 이어 외국인 환자 유치율 2위를 차지하고 있는 부산의 경우, 지난 8년간, 외국인 환자가 426%가량 증가하는 등 상당한 활성화가 되어있으며, 해상을 통해 입국한 러시아 환자 등의 다국적인 구성이 특징이다. 또한 부산권인 경남지역 중 김해와 창원은 외국인 거주자 수로 경남 도내 1위, 2위를 차지하고 있으며 다양한 외국인노동자들이 거주하고 있다. 종합병원과 같은 의료기관에서는 병원 내 길 찾기가 용이하여야 한다. 또한, 한국어, 영어, 중국어, 혹은 러시아어가 포함된 다양한 언어의 정보를 하나의 매개체 안에 전달해야 하는 공간이다. 이를 바탕으로 본 연구에서는 우리나라 언어에 미숙한 외국인들이 병원을 방문하였을 때 제시된 사인시스템에서 인지를 함에 있어서 쉽게 이해할 수 있도록 도와주는 융합적인 정보 전달을 목적으로 한다. 따라서 본 논문은 국내 제 2의 도시인 부산광역시 소재 대학병원 의료기관 6곳(A, B, C, D, E, F)과 부산권이면서 외국인 거주 비율이 높은 경상남도 김해시 의료기관(G, H), 창원시 대학병원 의료기관(R, J)등 총 10곳을 대상으로 사인시스템(유도사인, 안내사인, 실간판)의 현황을 파악하고 현재 적용되고 있는 다중언어 표기 실태 조사를 이행하였다. 연구결과 및 내용은 다음과 같다. 첫째, 사인시스템 디자인을 분석한 결과는 대체적으로 어두운 회색 및 채도가 높은 파란색 혹은 흰색의 바탕색을 적용한 후 서체는 무채색의 고딕체를 사용, 화살표 및 픽토그램으로 포인트 효과를 주어 일반적인 병원 사인시스템 디자인을 도입하고 있는 것으로 파악되었다. 둘째, 다중언어 실태의 결과는 주로 한국어, 영어와 같이 2가지의 언어만을 사인시스템에 도입하고 있는 곳과 지리적인 위치에 따라 한국어, 영어, 중국어, 러시아어와 같은 4가지의 언어를 적용시킨 곳도 조사되었다. 그러나 대부분의 의료기관은 현재 2가지의 언어(한국어, 영어)만이 적용되어져 있는 상황에 따라 영어권 나라가 아닌 타 국가의 외국인 환자들에게는 언어적인 측면에서 다소 불편한 점이 초래될 수 있다고 판단되었다. 이러한 연구결과를 바탕으로 추후에는 병원 사인시스템 다중언어 사용에서 외국인 사용자 뿐만 아니라 내국인들도 고려한 디자인을 제안하는 연구가 필요하다.

Convex Probe 소독 필요성 검증에 관한 연구 (A Study on the Necessity Verification of Convex Probe Disinfection)

  • 최관용;유세종;이준호;홍성용
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.193-200
    • /
    • 2019
  • 본 연구는 대전, 충청지역 초음파실 종사자를 대상으로 병원감염관리에 관한 설문 조사를 실시하여 분석하였고, ATP를 이용하여 임상에서 사용되는 초음파 Probe의 오염도를 측정하였으며, 70% 알코올 이용하여 소독한 후 결과를 확인하였다. 기본적인 조사 대상자의 일반적인 특성 및 직종 별 대상자의 특성으로 나누어 학력, 직종, 초음파 전문자격증 보유 유무, 기관 내 감염 담당 부서 및 감염 교육의 여부를 분석하였다. 검사 후 젤 제거 여부 및 방법, Probe의 소독여부 및 변수 별 상관분석을 수행하여 초음파 Probe의 세균감염에 관한 인식 및 세척 및 소독에 대한 수행 정도를 분석하였다. 검사 후 Probe 세척에 관하여 수건을 가장 많이 사용하였으며, Gel 용기는 3개월 이상 교환하지 않는 것으로 나타났다. 70% 알코올 소독 후 ATP 오염도는 $1055.4{\pm}944.2$에서 $133.5{\pm}93.2$으로 감소하였고 통계적으로 유의한 것으로 분석되었다.(${\rho}<0.01$) 병원균종은 CNS, Gram positive bacillus, Micrococcus species 검출되었다. 이를 해결하기 위해 시중에서 손쉽게 구할 수 있는 70% 알코올을 이용하여 소독을 실시하였으며 소독 후 병원균종은 검출되지 않았다. 연구 결과 초음파실을 관리하는 의료인 또는 의료기사 등은 감염관리에 대한 주기적인 교육과 감염예방에 대한 노력이 필요하다고 볼 수 있으며, 70% 알코올은 병원균 사멸에 효과적인 것으로 나타났다. 따라서 의료기관은 적극적인 병원감염관리 교육을 실시하여 종사자들의 병원감염에 관한 인식을 개선하고, 환자 감염 예방에 기여해야 할 것이다. 또한 본 연구 결과를 적절히 활용한다면 초음파 Probe를 매개로 한 감염 예방에 도움이 될 것으로 사료된다.