• Title/Summary/Keyword: patient dose

Search Result 1,801, Processing Time 0.029 seconds

A Study on Image Change according to Grid Ratio in Digital Radiography (디지털 방사선에서 격자 비에 따른 영상변화에 관한 연구)

  • Sung-Hun Jeong
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.89-97
    • /
    • 2023
  • With the introduction of the D.R system, the grid with high removal rate of scattered radiation is selected and used without considering the grid performance evaluation. Despite the high removal rate of scattered radiation belonging to high grid ratio, it is also possible to see the cut-off phenomenon in which the primary ray involved in the formation of image could be removed as well. Thus, the purpose of this study is to provide the basic data for researches on the usefulness of using the grid by presenting the appropriate grid ratio in the D.R system through the measurement of image in grid such as non-grid, 6:1, 8:1, 10:1, 12:1. The equipments used for this study were radiation generator with grid in 12:1, 10:1, 8:1, 6:1, indirect-type detector, and acryl phantom. As the study for image evaluation, this study measured the SNR, PSNR, MSE, and Entropy. In the results of this study, the PSNR was the highest in 6:1 and the lowest in 8:1. The SNR was high in 6:1 and 8:1, and the lowest in 12:1. In case of Entropy, it was high in 8:1 and 10:1, and the lowest in 12:1. Therefore, when the grid is used, it would be more proper to choose the grid in 8:1 or 10:1 with less loss in information content of primary ray rather than the high grid ratio showing the increased patient exposure dose.

Study on Methods to Improve Image Quality of Abdominal CT Images (복부 CT 영상의 화질 개선 방법에 대한 연구)

  • Seok-Yoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.717-723
    • /
    • 2023
  • Liver disease is highly associated with death, and other abdominal diseases are also important causes affecting a person's lifespan, and a CT scan is essential when treating abdominal diseases. High radiation exposure is essential to create images that are good for reading, but managing the patient's radiation exposure is also essential. In this study, a post-processing wavelet algorithm was proposed to improve the image quality of abdominal CT images. Wavelets have the disadvantage of having to set a threshold value depending on the type of input image. Therefore, we experimentally proposed the threshold value of the wavelet and evaluated whether the image quality was effective. As a result of the experiment, the optimal threshold value for abdominal CT images was calculated to be 50. In the case of image 1, noise was improved by 49% and in the case of image 2, by 29%, and the contrast also increased. if the results of this study are applied for post-processing after abdominal CT, image quality can be improved and it will be helpful in disease diagnosis.

Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors (휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.897-902
    • /
    • 2023
  • The purpose of this paper is to analyze the characteristics of Silicon Photomultiplier (SiPM) for the realization of high-sensitivity radiation detection in portable detectors. Portable X-ray detectors offer the advantage of quickly accessing the patient's location and obtaining real-time images, allowing physicians to perform rapid diagnoses. However, this mobility comes with challenges in achieving accurate radiation detection. In existing detectors, SiPM is used for a simple purpose of detecting X-ray triggers. To verify the feasibility of high-sensitivity X-ray detection through SiPM, seven types of SiPM sensors were compared and selected, and their characteristics were analyzed. The SiPM used in the final test demonstrated the ability to distinguish signals at the ultra-low radiation level of 10 nGy, and it was observed that the slope of the signal rise curve varies with the X-ray tube voltage. Utilizing the characteristics of SiPM, which exhibits changes in signal level and duration with X-ray dose, it appears possible to achieve high-sensitivity measurements for X-ray detection.

A Randomized Trial Comparing the Effect of Unani Formulation with Metronidazole in Bacterial Vaginosis

  • Nazia Usmoni;Mariyam Roqaiya;Mohd Aqil Quadri;Arshiya Sultana;Taseen Banu;Sumbul Alam
    • CELLMED
    • /
    • v.13 no.14
    • /
    • pp.18.1-18.13
    • /
    • 2023
  • Background and objectives: Bacterial vaginosis (BV) is recognized as the most prevalent type of vaginal infection, impacting approximately 19-24% of women in their reproductive years. The recurrence rate of BV is significant, negatively impacting the well-being of affected women. This study aimed to compare the therapeutic effects of a polyherbal Unani formulation and metronidazole in treating bacterial vaginosis. Methodology: In this prospective patient blinded standard controlled trial, a total of 40 individuals with a clinical diagnosis of bacterial vaginosis were randomly assigned to receive either an active control treatment (n = 20) or a test drug (n = 20). In the test drug combination of Acacia catechu, Azadirachta indica and Quercus infectoria in tablet (1g) form in the dose of 2 tablets orally twice daily with water was administered for 3 weeks. In the active control standard drug, metronidazole 400 mg tablet, orally twice daily was given for one week. The primary outcome measure was clinical cure; H. negative Amsel's criteria and a reduction in subjective symptoms, while the secondary outcome measure was an improvement in SF-36 quality of life (QOL). Results and conclusion: Both the experimental treatment and the metronidazole demonstrated a significant clinical cure for bacterial vaginosis as well as an increase in health-related quality of life. Based on these findings, it appears that the test medication is a potent Unani formulation for the treatment of bacterial vaginosis. A well conducted trial with a bigger sample size is required to corroborate these findings.

Using 2-mSv Appendiceal CT in Usual Practice for Adolescents and Young Adults: Willingness Survey of 579 Radiologists, Emergency Physicians, and Surgeons from 20 Hospitals

  • Hyuk Jung Kim;Kyoung Ho Lee;Min-Jeong Kim;Sung Bin Park;Yousun Ko;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.68-76
    • /
    • 2020
  • Objective: To survey care providers' willingness to use 2-mSv computed tomography (CT) in their usual practice for adolescents and young adults with suspected appendicitis. Materials and Methods: An ethical committee approved this prospective study. We introduced 2-mSv CT in 20 hospitals through a pragmatic clinical trial. At the final phase of the trial, we invited 698 potentially-involved care providers in the survey regarding their willingness to use 2-mSv CT. Multivariable logistic regression analyses were performed to identify factors associated with willingness. Nine months after the completion of the trial patient recruitment, we surveyed whether the hospitals were using 2-mSv CT in usual practice. Results: The analyses included responses from 579 participants (203 attendings and 376 trainees; 221 radiologists, 196 emergency physicians, and 162 surgeons). Regarding the willingness to immediately change their standard practice to 2-mSv CT, 158 (27.3%), 375 (64.8%), and 46 (7.9%) participants responded as "yes" (consistently), "partly" (selectively), and "no", respectively. Willingness varied considerably across the hospitals, but only slightly across the participants' departments or job titles. Willingness was significantly associated with attendings (p = 0.004), intention to maintain the dedicated appendiceal CT protocol (p < 0.001), belief in compelling evidence on the carcinogenic risk of conventional-dose CT radiation (p = 0.028), and hospitals having more than 1000 beds (p = 0.031). Fourteen of the 20 hospitals kept using 2-mSv appendiceal CT in usual practice after the trial. Conclusion: Despite the extensive efforts over the years of this clinical trial, many care providers were willing to use 2-mSv CT selectively or not willing to use.

Effectiveness and Safety of Pharmacopuncture Therapy for Chronic Low Back Pain: A Study Protocol for a Pragmatic Randomized Controlled Trial

  • Youn Young Choi;Hwa Yeon Ryu;Jae Hui Kang;Hyun Lee
    • Journal of Acupuncture Research
    • /
    • v.41 no.2
    • /
    • pp.107-114
    • /
    • 2024
  • Background: Low back pain (LBP) is a common musculoskeletal disorder worldwide, with a lifetime prevalence of up to 80%. Among nonsurgical treatments for chronic LBP, Korean medicine treatments are highly preferred, and pharmacopuncture therapy combining acupuncture and herbal medicine is widely used. However, no evidence-based study has focused on the use of various types of pharmacopuncture. Methods: The pragmatic randomized controlled clinical trial will include 44 participants; recruitment will start in July 2023. All participants will receive integrated Korean medicine treatment including acupuncture, cupping, and infrared therapy, and the intervention group will also receive pharmacopuncture. After 16 treatment sessions, twice a week for 8 weeks, follow-up assessments will be performed at week 9. As a pragmatic randomized controlled clinical protocol, the type, dose, and acupoints of acupuncture and pharmacopuncture are not determined in advance but are selected and recorded according to the clinical judgment of the Korean medicine doctor. Results: The primary outcome will be measured using a visual analog scale score, and the secondary outcomes include the Oswestry disability index, patient global impression of change, no worse than mild pain, and range of motion. Safety will be assessed by examining participants' self-reported adverse events and vital signs and conducting blood tests before and after the test. Conclusion: This study aims to provide clinical evidence of the effectiveness and safety of pharmacopuncture for chronic LBP.

Feasibility of Gamma Knife Radiosurgery for Brain Arteriovenous Malformations According to Nidus Type

  • Ja Ho Koo;Eui Hyun Hwang;Ji Hye Song;Yong Cheol Lim
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.431-441
    • /
    • 2024
  • Objective : Gamma Knife radiosurgery (GKRS) is an effective and noninvasive treatment for high-risk arteriovenous malformations (AVMs). Since differences in GKRS outcomes by nidus type are unknown, this study evaluated GKRS feasibility and safety in patients with brain AVMs. Methods : This single-center retrospective study included patients with AVM who underwent GKRS between 2008 and 2021. Patients were divided into compact- and diffuse-type groups according to nidus characteristics. We excluded patients who performed GKRS and did not follow-up evaluation with magnetic resonance imaging or digital subtraction angiography within 36 months from the study. We used univariate and multivariate analyses to characterize associations of nidus type with obliteration rate and GKRS-related complications. Results : We enrolled 154 patients (mean age, 32.14±17.17 years; mean post-GKRS follow-up, 52.10±33.67 months) of whom 131 (85.1%) had compact- and 23 (14.9%) diffuse-type nidus AVMs. Of all AVMs, 89 (57.8%) were unruptured, and 65 (42.2%) had ruptured. The mean Spetzler-Martin AVM grades were 2.03±0.95 and 3.39±1.23 for the compact- and diffuse-type groups, respectively (p<0.001). During the follow-up period, AVM-related hemorrhages occurred in four individuals (2.6%), three of whom had compact nidi. Substantial radiation-induced changes and cyst formation were observed in 21 (13.6%) and one patient (0.6%), respectively. The AVM complete obliteration rate was 46.1% across both groups. Post-GKRS complication and complete obliteration rates were not significantly different between nidus types. For diffuse-type nidus AVMs, larger AVM size and volume (p<0.001), lower radiation dose (p<0.001), eloquent area location (p=0.015), and higher Spetzler-Martin grade (p<0.001) were observed. Conclusion : GKRS is a safe and feasible treatment for brain AVMs characterized by both diffuse- and compact-type nidi.

Dermatofibrosarcoma Protuberans on the Occipital Scalp Showed Uncommon Presentation: A Case Report (비전형적 임상양상을 보이는 후두부의 융기성 피부 섬유 육종에 대한 증례보고)

  • Jiwon Jeong;Chul Hoon Chung;SeongJin Cho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.40 no.1
    • /
    • pp.49-53
    • /
    • 2024
  • Dermatofibrosarcoma protuberans (DFSP) is a rare soft tissue sarcoma, with an incidence of about 0.8% to 5% per million people per year, accounting for 1% of soft tissue sarcomas. In its early stage, DFSP is typically found as a violet or pinkish macule or patch, and it can develop into a palpable mass with ulceration or bleeding. The standard treatment for DFSP is wide local excision of the tumor with a 2- to 3-cm negative margin, and radiation therapy or chemotherapy can be conducted with surgical treatment. A 35-year-old man had a palpable mass on the left side of his occipital scalp without color change, ulceration, or bleeding, which typically are present in malignancy. A magnetic resonance imaging (MRI) scan showed a 3-cm homogenous enhanced mass without adhesion between the scalp and the mass. Unexpectedly, a biopsy revealed the round mass to be DFSP. A wide excision and rotation of the scalp flap were performed. The patient recovered without any complications and received adjuvant radiotherapy at a dose of 60 Gray (Gy) for six weeks. There was no recurrence through six months of follow-up. Here we report this unique case of DFSP with atypical presentation.

Impact of dental imaging on pregnant women and recommendations for fetal radiation safety: A systematic review

  • Thiago Oliveira Gamba;Fernanda Visioli;Deise Renata Bringmann;Pantelis Varvaki Rados;Heraldo Luis Dias da Silveira;Isadora Luana Flores
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: This study was conducted to investigate the safety of dental imaging in pregnant women with respect to fetal health. Materials and Methods: Searches were conducted of the PubMed, Scopus, and Web of Science databases in May 2023. The inclusion criteria encompassed cross-sectional and longitudinal studies that focused on the analysis of diagnostic dental imaging in pregnant women, as well as studies utilizing phantoms to simulate imaging examinations. The exclusion criteria consisted of reviews, letters to the editor, book chapters, and abstracts from scientific conferences and seminars. Results: A total of 3,913 articles were identified. Based on a review of the titles and abstracts, 3,892 articles were excluded, leaving 21 articles remaining for full-text review. Of these, 18 were excluded, and 4 additional articles were included as cross-references. Ultimately, 7 articles underwent quantitative-qualitative analysis. Three retrospective studies were focused on pregnant women who underwent dental imaging procedures. The remaining 4 studies utilized female phantoms to simulate imaging examinations and represent the radiation doses absorbed by the uterus or thyroid. Conclusion: Few dental radiology studies have been conducted to determine the safe radiation threshold for pregnant women. Additionally, the reviewed articles did not provide numbers of dental examinations, by type, corresponding to this dose. Dental imaging examinations of pregnant women should not be restricted if clinically indicated. Ultimately, practitioners must be able to justify the examination and should adhere to the "as low as diagnostically acceptable, being indication-oriented and patient-specific" (ALADAIP) principle of radioprotection.

Updated guidelines for prescribing opioids to treat patients with chronic non-cancer pain in Korea: developed by committee on hospice and palliative care of the Korean Pain Society

  • Minsoo Kim;Sun Kyung Park;Woong Mo Kim;Eunsoo Kim;Hyuckgoo Kim;Jun-Mo Park;Seong-Soo Choi;Eun Joo Choi
    • The Korean Journal of Pain
    • /
    • v.37 no.2
    • /
    • pp.119-131
    • /
    • 2024
  • There are growing concerns regarding the safety of long-term treatment with opioids of patients with chronic non-cancer pain. In 2017, the Korean Pain Society (KPS) developed guidelines for opioid prescriptions for chronic non-cancer pain to guide physicians to prescribe opioids effectively and safely. Since then, investigations have provided updated data regarding opioid therapy for chronic non-cancer pain and have focused on initial dosing schedules, reassessment follow-ups, recommended dosage thresholds considering the risk-benefit ratio, dose-reducing schedules for tapering and discontinuation, adverse effects, and inadvertent problems resulting from inappropriate application of the previous guidelines. Herein, we have updated the previous KPS guidelines based on a comprehensive literature review and consensus development following discussions among experts affiliated with the Committee on Hospice and Palliative Care in the KPS. These guidelines may assist physicians in prescribing opioids for chronic non-cancer pain in adult outpatient settings, but should not to be regarded as an inflexible standard. Clinical judgements by the attending physician and patient-centered decisions should always be prioritized.