• Title/Summary/Keyword: passive system

Search Result 2,258, Processing Time 0.039 seconds

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.E1
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).

Performance Verification of Smart Passive Damping System using MR damper (자기유변유체 감쇠기에 기반한 스마트 수동 감쇠 시스템의 성능 평가)

  • Cho, Sang-Won;Jang, Ji-Eun;Yoon, Woo-Hyun;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.505-512
    • /
    • 2005
  • MR damper is one of the most promising control devices for civil engineering applications to earthquake hazard mitigation. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes and experimentally verified a smart passive damping system using MR(Magnetorheological) dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. It is easy to build up and maintain EMI system, because it does not require any control system such as a power supply, controller, and sensors. Numerical simulations using experimental model of EMI system are carried to verify the effectiveness of the proposed EMI system. The performances of smart passive damping system are compared with those of passive and semiactive MR dampers.

  • PDF

Passive acoustic fish detection analysis and its feasible aspects (수동어탐의 가능성과 전망)

  • 장지원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.4
    • /
    • pp.98-103
    • /
    • 1986
  • The passive acoustic system only has generally used in fish detection. But the passive acoustic system has not been tried in fishing since Freytag has proposed a possibilities of the passive detection of fishes in 1963. This paper describes the .feasible aspects of fish detection by listening of the sound they make. The passive acoustic system accompanied the active acoustic system may expand the range of detection and compensate for lack of capabilities each other, but there are some difficulties in noise rejection because the fre9uency range of ship noises covers the whole range vf biological sounds. The attempt to collect useful informations from underwater would be greatly contributed in fisheries.

  • PDF

A Study on the Reliability of Superconducting Fault Current Limiter (초전도한류기의 신뢰도에 관한 연구)

  • Bae, In-Su;Kim, Sung-Yul;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.101-106
    • /
    • 2011
  • The failure of cooling system in Superconducting Fault Current Limiter(SFCL) increases the impedance of superconducting device, and due to malfunction of inner switches the SFCL opens the distribution system inadvertently when required to do so. In this paper, the ground fault and short circuit fault were classified as active failure and the open circuit fault was passive failure. A reliability model of SFCL considers the passive failure as well as active failure, and in the case study the reliability indices of distribution system are evaluated. It is possible that the reliability evaluation excluded passive failure makes the customers reliability seem so worse than it really was. Therefore, the reliability models of SFCL must include the active failure and passive failure together to evaluate the reliability of distribution system connected SFCL.

Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory (외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구)

  • Hwang, Ji Hyun;Bum, Do;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

Optimal Design of Hybrid Control System through Inter-Building Connection (빌딩간 연결을 통한 복합제어시스템의 최적설계)

  • Park, Kwan-Soon;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.81-88
    • /
    • 2017
  • This study deals with the optimal design of a hybrid control system composed of a combination of active control system and passive control system for effective seismic performance improvement of two adjacent structures. The proposed hybrid control system adopts a configuration of installing an active control device in one building and connecting two adjacent structures with a passive control device so that the one-side active control force can be bi-directionally applied to both buildings through the passive connecting devices. In order to derive the optimal performance of the proposed system, the design parameters of the passive and active control systems were searched using the genetic algorithm. Numerical simulations of 10-story and 8-story buildings have been performed to verify the effectiveness of the proposed technique. For the purpose of comparison, the conventional independent control system with two identical active control systems being installed separately for each structure was also optimally designed and its seismic response has been evaluated as well. From the comparative results of the two control systems, it is demonstrated that the proposed hybrid control system requires larger control force for its one-side active control device than the conventional independent control system does for each of both-side active devices, but quite less than the total control force required for both-side devices of the independent control system, while maintaining similar seismic performance. Therefore, the proposed system is more economical and reliable than the conventional independent control system with two identical active devices.

Decentralized Output Feedback Robust Passive Control for Linear Interconnected Uncertain Time-Delay Systems

  • Shim, Duk-Sum
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.2
    • /
    • pp.140-146
    • /
    • 2002
  • We consider a class of large-scale interconnected time delay systems and investigate a decentralized robust passive control problem. sufficient conditions for unforced interconnected uncertain systems with time delay to be robustly stable with extended strictly passivity is given in terms of algebraic Riccati inequality and linear matrix inequality. The decentralized robust passive control problem for norm-bounded and positive real uncertainty is shown to be converted to extended strictly positive real control problem for a modified system which contains neither time delay nor uncertainty.

SAFETY ANALYSIS OF INCREASE IN HEAT REMOVAL FROM REACTOR COOLANT SYSTEM WITH INADVERTENT OPERATION OF PASSIVE RESIDUAL HEAT REMOVAL AT NO-LOAD CONDITIONS

  • SHAO, GE;CAO, XUEWU
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.434-442
    • /
    • 2015
  • The advanced passive pressurized water reactor (PWR) is being constructed in China and the passive residual heat removal (PRHR) system was designed to remove the decay heat. During accident scenarios with increase of heat removal from the primary coolant system, the actuation of the PRHR will enhance the cooldown of the primary coolant system. There is a risk of power excursion during the cooldown of the primary coolant system. Therefore, it is necessary to analyze the thermal hydraulic behavior of the reactor coolant system (RCS) at this condition. The advanced passive PWR model, including major components in the RCS, is built by SCDAP/RELAP5 code. The thermal hydraulic behavior of the core is studied for two typical accident sequences with PRHR actuation to investigate the core cooling capability with conservative assumptions, a main steam line break (MSLB) event and inadvertent opening of a steam generator (SG) safety valve event. The results show that the core is ultimately shut down by the boric acid solution delivered by Core Makeup Tank (CMT) injections. The effects of CMT boric acid concentration and the activation delay time on accident consequences are analyzed for MSLB, which shows that there is no consequential damage to the fuel or reactor coolant system in the selected conditions.

Analysis and Design of a Passive Harmonic Filter for a Three-Phase Rectifier (3상 정류기부하에 대한 수동 고조파필터의 해석 및 설계)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.316-322
    • /
    • 2009
  • This paper presents an analytical design method of a passive harmonic filter for a three-phase diode rectifier and uses a new transfer function approach in the analysis and design. The transfer function approach derives an analytical formulation of an utility system including passive filters with a basis of Laplace transform and provides a graphical formulation so that a visualized insight into an interaction between individual filter and system response can be attainted. Harmonic impedance, voltage division and current division transfer function are used as a design tool, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. A simple five-step design procedure is introduced in the filter design, which consists of system analysis, selection of PCC(Point of Common Coupling), filter specification calculation, appropriate filter design for system and filter implementation. Philosophy governing the design procedure is based on a numerical/graphical iterative solution, trial and error with visualization feed-back based on "algebra on the graph". Finally, performance of the designed passive harmonic filter is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th harmonics are decreased within IEEE-519 distortion limits, respectively.