• Title/Summary/Keyword: passive system

Search Result 2,258, Processing Time 0.025 seconds

Design of Passive Filter for Harmonic Elimination of the Load System (부하설비의 고조파 저감을 위한 수동필터 설계)

  • Son, Jae-Hyun;Kang, Chang-Seob;Lee, Hong-Gee;Yoon, Chul-Sup
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.276-278
    • /
    • 1997
  • The aim of this study is to design a passive filter for the elimination of harmonics. For this design, the harmonics wave generating from the six pulse rectifier was measured and its characteristics were analyzed. We also calculated the quantity of harmonic current by changing the system operational conditions. According to this field data and calculated results. we determined the elements of the passive filter. The simulation results indicate the efficiency of designed passive filter.

  • PDF

Korean Learners' Development of English Passive Constructions

  • Park, Hye-Sook
    • English Language & Literature Teaching
    • /
    • v.15 no.4
    • /
    • pp.199-216
    • /
    • 2009
  • This study investigates how Korean speakers develop their interlanguage of English passive constructions with a reference to the learners' grammar proficiency levels. Sixty two college students of different levels of English participated in this study. They were asked to complete a sentence-completion task. Their production was classified into accurate passives, malformed passives, pseudo-passives, unaccusatives, and actives according to the use of transitive, ergative and unergative verbs. They then were further analyzed depending on the subjects' levels of grammar by three main factors: L1 transfer, the English voice system, and universal cognitive factors. The results showed that the subjects of the lower group produced more pseudo-passives, malformed passives, and overpassivization than those of the higher group, and even subjects of higher group still made passives for ergative verbs. It was also shown that L1 and universal factors had more influence on the lower group than on the higher group. Based on the analyses of the subjects' responses, the development of the English passive system by Korean learners is shown and some implications are suggested for effective teaching of English.

  • PDF

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

Passive p-y curves for rigid basement walls supporting granular soils

  • Imad, Elchiti;George, Saad;Shadi S., Najjar
    • Geomechanics and Engineering
    • /
    • v.32 no.3
    • /
    • pp.335-346
    • /
    • 2023
  • For structures with underground basement walls, the soil-structure-interaction between the side soil and the walls affects the response of the system. There is interest in quantifying the relationship between the lateral earth pressure and the wall displacement using p-y curves. To date, passive p-y curves in available limited studies were assumed elastic-perfectly plastic. In reality, the relationship between earth pressure and wall displacement is complex. This paper focuses on studying the development of passive p-y curves behind rigid walls supporting granular soils. The study aims at identifying the different components of the passive p-y relationship and proposing a rigorous non-linear p-y model in place of simplified elastic-plastic models. The results of the study show that (1) the p-y relationship that models the stress-displacement response behind a rigid basement wall is highly non-linear, (2) passive p-y curves are affected by the height of the wall, relative density, and depth below the ground surface, and (3) passive p-y curves can be expressed using a truncated hyperbolic model that is defined by a limit state passive pressure that is determined using available logarithmic spiral methods and an initial slope that is expressed using a depth-dependent soil stiffness model.

Problems and improvement methods of passive treatment systems for acid mine drainage in Korea

  • Ji, Sang-Woo;Ko, Ju-In;Kim, Sun-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.504-510
    • /
    • 2003
  • This study has been carried out to evaluate the passive treatment systems for acid mine drainage in Korea and to suggest, if possible, the method for the improvement. 35 passive treatment systems in 27 mines have been constructed since 1996. SAPS, being the main process, was combined with more than one of processes such as anaerobic wetland, aerobic wetland, and oxidation pond for the construction of passive treatment system. Problems observed during the operation include the poor sulfate removal ratio, overflow, leakage, unusabless of the whole system, and inefficiency. The reasons of the poor sulfate removal ratio are believed that the low temperature during the winter prohibits the SRB activity and HRT for bacterial sulfate reduction is insufficient. An alternative method In Adit Sulfate Reducing System which enables to keep the temperature constant at about $15^{\circ}C$ was suggested. IASRS is the methods of placing the SAPS inside the adit, which enables the temperature around the system constant can be maintained. The experiments using the laboratory scaled model systems made up of four sections showed high efficiencies in pH control and metal removal ratios, but showed still low sulfate removal ratio of about $23\%$ also with high COD at the beginning of the operation.

  • PDF

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

Single Axis Vibration Isolation System Using Series Active-passive Approach (직렬형 능-수동 제진 방법을 이용한 1축 제진 시스템)

  • Banik, Rahul;Lee, Dong-Yeon;Gweon, Dae-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.176-179
    • /
    • 2005
  • To control the vibration transmitted to the precision instruments from ground has always been of great interest among the researchers. This paper proposes a single axis vibration isolation system which can be used as a module far a table top six axis isolator for highly precise measurement and actuation system. The combined active-passive isolation principle is used for vertical vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in series which consists of very stiff piezo actuator. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator. The active stage is isolated from the payload disturbance through the Passive stage and thus modularity in control is achieved. This made the control algorithm much easier as it does not need to be tuned to specific payload.

  • PDF

Implementation of Multi-Band Mobile PIMD Measurement System. (Multi-Band 이동통신용 수동혼변조왜곡 측정시스템 개발)

  • Park, Ki Won;Shin, Dong Whan;Rhee, Young Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.703-705
    • /
    • 2016
  • In this paper, we developed a wideband PIMD system to measure passive intermodulation distortion signals of mobile communication RF passive module. To represent wideband characteristic, we designed a receiver that meets low-noise and wideband characteristics in RF receiver. It allows high dynamic range in the RF receiver front end. In designed passive intermodulation distortion measurement system, we programed to display a PIMD signal with FPGA/DSP at PC. Implemented PIMD system was variable from 650 MHz to 2700 MHz and show up to -138 dB minimum detectable $3^{rd}$ passive inetrmodulation distortion signal.

  • PDF

Design of power amplifier and antenna for wireless power transmission in 125kHz (125kHz대에서 무선전력전송을 위한 전력증폭기와 송수신 Antenna 설계)

  • Im, Sang-Uk;Kim, Yong-Sang;Kim, Do-Hun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.27-30
    • /
    • 2003
  • Wireless power transmission system is one of the very interesting field not only in a technical and economical point of view but also that people are still trying to realize lossless power transmission. This paper has a purpose on the efficient power transmission at the passive type ICcard by using wireless power transmission system. The most difficult but important part of the passive type RF-ID system is building the system that supplies power from Reader-antenna to IDcard-antenna. To check what is the most efficient way to deliver power depending on what kind of specifications of the power-amp in reader, antenna and antenna in IDcard is for operating IDcard circuit efficiently receiving the power from reader-antenna. For this, we used 125kHz sinewave for RF signal as a basic specification, power-amp : OP-Amp for amplifying signal and AB Class push-pull power-amp for amplifying power, loop type antenna.

  • PDF

Wheeled Blimp: Hybrid Structured Airship with Passive Wheel Mechanism for Tele-guidance Applications

  • Kang, Sung-Chul;Nam, Mi-Hee;Kim, Bong-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1941-1948
    • /
    • 2004
  • This paper presents a novel design of indoor airship having a passive wheeled mechanism and its stationary position control. This wheeled blimp can work both on the ground using wheeled vehicle part and in the air using the floating capability of the blimp part. The wheeled blimp stands on the floor keeping its balance using a caster-like passive wheel mechanism. In tele-guidance application, stationary position control is required to make the wheeled blimp naturally communicate with people in standing phase since the stationary blimp system responds sensitively to air flow even in indoor environments. To control the desired stationary position, a computed torque control method is adopted. By performing a controller design through dynamic analysis, the control characteristics of the wheeled blimp system have been found and finally the stable control system has been successfully developed. The effectiveness of the controller is verified by experiment for the real wheeled blimp system.