• Title/Summary/Keyword: passive filter

Search Result 359, Processing Time 0.02 seconds

Development of the Hybrid EMI Filter for DC-DC Converter (DC-DC 전력변환장치용 Hybrid EMI 필터 개발)

  • Lee, Dong-Ho;Yoo, Jin-Wan;Park, Chong-Yeun
    • Journal of Industrial Technology
    • /
    • v.34
    • /
    • pp.71-78
    • /
    • 2014
  • Recently, using the electronic devices was increased with semiconductor developments. So, the EMI(Electromagnetic interference) problem become to important issue for coexistence with each electronic devices. The EMI is caused by switching operation from the power switches as the FET and the transistor in power conversion devices. In this paper, the hybrid EMI filter that composed with active components and passive components was described. The EMI filter is applied to the 160 watts LED driver experimentally verify the performance. The hybrid EMI filter is compared with non-filter, only passive filter and only active filter. The proposed EMI filter attenuated CM noise more than traditional passive filter.

  • PDF

Characteristics Analysis of Reactor Considering Magnetization Saturation (포화특성을 고려한 리액터의 특성 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • As the increasing of non-linear load, filter is coming to be high gradually in order to reduce the harmonic which occurs from the power conversion. The maintenance of passive filter is easier than active filter and it has been widely used in the industrial site. This passive filter is connected with condenser and reactor by series and parallel and it is installed at the front of nonlinear load. The breakdown of passive filter occurs frequently at the reactor side rather than capacitor. So the breakdown cause close examination is necessary. In this paper, we analyzed that the electric stress of reactor which is considered magnetization saturation at the passive filter. We confirm that the reduction of harmonics and the electric stress of reactor is influenced by the linear and non-linear element of reactor.

Three-Phase Hybrid Shunt Filters for Power Quality Improvement

  • Bhuvaneswari, G.;G.Nair, Manjula
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.257-264
    • /
    • 2007
  • Active power filters can be cost-effective for use in practical systems with the insertion of a few passive elements in shunt or series configuration. The resulting hybrid filters can be designed to provide dominant lower order harmonic elimination and reactive power support by the passive elements so that the burden on the active filter counterpart is reduced. In this paper, the rate reduction in the shunt active filter is estimated when it is connected in parallel with suitable passive tuned harmonic filters. The active filtering system is based on an appropriate control scheme. The simulation and the experimental results of the shunt active filter, along with the estimated value of reduction in rating, show that the hybrid shunt filtering system is quite effective in compensating for the harmonics and reactive power, in addition to being cost-effective.

Design Methodology of Passive Damped LCL Filter Using Current Controller for Grid-Connected Three-Phase Voltage-Source Inverters

  • Lee, Jun-Young;Cho, Young-Pyo;Kim, Ho-Sung;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1178-1189
    • /
    • 2018
  • In grid-connected voltage-source inverters (VSIs), when compared with a simple inductive L filter, the LCL filter has a better performance in attenuating the high frequency harmonics caused by the pulse-width modulation of power switches. However, the resonance peaks generated by the filter inductors and capacitors can make a system unstable. In terms of simplicity and filter design cost, a passive damping method is generally preferred. However, its high power loss and degradation in high frequency harmonic attenuation are significant demerits. In this paper, a mathematical design solution for a passive LCL filter to derive filter parameters suppressing the high frequency current harmonics to 0.3% is proposed. The minimum filter inductance can be obtained to reduce the size of the filter. Furthermore, a minimum damping resistance design considering a current controller is analyzed for a stable closed-loop system. The proposed design method is verified by experimental results using a 5-kW three-phase prototype inverter.

Linear Distributed Passive Target Tracking Filter for Cooperative Multiple UAVs (다중 UAV 협업을 위한 선형 분산 피동 표적추적 필터 설계)

  • Lee, Yunha;Kim, Chan-Young;Ra, Won-Sang;Whang, Ick-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.314-324
    • /
    • 2018
  • This paper proposes a linear distributed target tracking filter for multiple unmanned aerial vehicles(UAVs) sharing their passive sensor measurements through communication channels. Different from the conventional nonlinear filtering schemes, the distributed passive target tracking problem is newly formulated within the framework of a linear robust state estimation theory incorporated with a linear uncertain measurement equation including the coordinate transform uncertainty. To effectively cope with the performance degradation due to the coordinate transform uncertainty, a linear consistent robust Kalman filter(CRKF) theory is devised and applied for designing a distributed passive target tracking filter. Through the simulations for typical UAV surveillance mission, the superior performance of the proposed method over the existing schemes of distributed passive target tracking are demonstrated.

A Study of Ozone Passive Sampler(I)-Sensitivity on Filter Substrate (오존 간이측정기에 대한 연구(I)-필터의 민감도)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.383-391
    • /
    • 2002
  • Six types of ozone passive samplers were fabricated with three different filter substrates and two colorants, and tested for their feasibility on atmospheric monitoring. These passive samplers are based on a colorant which fades (indigo carmine and ChromAir (K&M environmental Inc.)) or produces color (mixture of 3-methyl-2-benzothiazolinone acetone azine and 2-phenylphenol colorant) upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Three filters, namely Whatman No.1 paper, SG81 chromatography paper and Silica Gel coated on polyester (TLC Plates), were prepared and coated with two colorants. The response of these passive samplers in ozone chamber were tested and compared with ChromAir (K&M environmental Inc.) passive sampler. The response of Silica Gel filter impregnated with indigo carmine was the best at the constant concentration exposure.

Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems

  • Kececioglu, O. Fatih;Acikgoz, Hakan;Yildiz, Ceyhun;Gani, Ahmet;Sekkeli, Mustafa
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.207-216
    • /
    • 2017
  • Wind energy conversion systems (WECS) which consist of wind turbines with permanent magnet synchronous generator (PMSG) and full-power converters have become widespread in the field of renewable power systems. Generally, conventional diode bridge rectifiers have used to obtain a constant DC bus voltage from output of PMSG based wind generator. In recent years, together advanced power electronics technology, Pulse Width Modulation (PWM) rectifiers have used in WECS. PWM rectifiers are used in many applications thanks to their characteristics such as high power factor and low harmonic distortion. In general, L, LC and LCL-type filter configurations are used in these rectifiers. These filter configurations are not exactly compensate current and voltage harmonics. This study proposes a hybrid passive filter configuration for PWM rectifiers instead of existing filters. The performance of hybrid passive filter was tested via MATLAB/Simulink environment under various operational conditions and was compared with LCL filter structure. In addition, neuro-fuzzy controller (NFC) was preferred to increase the performance of PWM rectifier in DC bus voltage control against disturbances because of its robust and nonlinear structure. The study demonstrates that the hybrid passive filter configuration proposed in this study successfully compensates current and voltage harmonics, and improves total harmonic distortion and true power factor.

A Passive Ranging Filter with Initial Range Error Compensation (초기 거리오차 보상 피동 거리 추정 필터)

  • 황익호;정상근
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.185-194
    • /
    • 2002
  • To extract relative ranges from LOS(line of sight) information, we propose a passive ranging filter which is suitable for anti-ship missiles in HOJ(home on jam) mode. The proposed filter is devised to cope with the case that a passive ranging filter may include a large initial range estimation error since modem jammers are capable of very long range jamming. In addition, under the assumption that the missile motion is dominant over the HOJ engagement situation, the engagement geometry is modeled by a second order system. A new passive ranging filter is proposed by constructing an extended Kalman filter(EKF) based on the model. And then a least square initial state error estimation algorithm is attached to the EKF. Simulation results show that the proposed filter has a good range estimation performance with small computational load.

Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters

  • Liu, Cong;Dai, Ke;Duan, Kewei;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1058-1069
    • /
    • 2013
  • This paper proposes and designs a new output filter called an LCFL filter for application to three phase three wire shunt active power filters (SAPF). This LCFL filter is derived from a traditional LCL filter by replacing its capacitor with a C-type filter, and then constructing an L-C-type Filter-L (LCFL) topology. The LCFL filter can provide better switching ripple attenuation capability than traditional passive damped LCL filters. The LC branch series resonant frequency of the LCFL filter is set at the switching frequency, which can bypass most of the switching harmonic current generated by a SAPF converter. As a result, the power losses in the damping resistor of the LCFL filter can be reduced when compared to traditional passive damped LCL filters. The principle and parameter design of the LCFL filter are presented in this paper, as well as a comparison to traditional passive damped LCL filters. Simulation and experimental results are presented to validate the theoretical analyses and effectiveness of the LCFL filter.

Design of harmonic reduction equipment for load system (부하설비의 고조파 저감장치 설계)

  • Son, Jae-Hyun;Cho, Yang-Heang;Kim, Je-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.224-228
    • /
    • 2006
  • The aim of this study is to design a passive filter for the elimination of harmonics. For this design, the harmonics wave generating from the six pulse rectifier was measured and its characteristics were analyzed. We also calculated the quantity of harmonic current by changing the system operational conditions. According to this field data and calculated results, we determined the elements of the passive filter. The simulation and experimental results indicate the efficiency of designed passive filter.

  • PDF