• 제목/요약/키워드: passive control systems

검색결과 463건 처리시간 0.024초

시간 지연을 가지는 수동성 양방향 텔레오퍼레이션 시스템 (Passivity Bilateral Teleoperatio System with Time Delay)

  • 장창레이;정길도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.333-335
    • /
    • 2006
  • This paper presents a force-reflecting teleoperation scheme with time delay. In reciprocal systems, to improve the stability and performance of the tleleoperation system, the network provides a wide bandwidth, no congestion. However, as use of Internet increases, congestion situation of network increased and transmission time and packet loss increased accordingly. This can make system unstable at remote control. In this paper, we present a passive control scheme for a force reflecting bilateral teleoperation system via the Internet and we investigated how a varying time delay affects the stability of a teleoperation system. A new approach based on a passive control scheme was designed for the system. The simulation results and the tracking performance of the implemented system are presented in this paper.

  • PDF

DESIRABLE PARAMETER IDENTIFICATION FOR THE IMPLEMENTATION OF IDEAL PASSIVE FAULT CURRENT LIMITER FOR THE PROTECTION OF POWER SEMICONDUCTOR DEVICES

  • Mukhopadhyay, S.C.;Iwahara, M.;Yamada, S.;Dawson, F.P.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.859-864
    • /
    • 1998
  • Compact and small size, reliable and failsafe operation and low cost featuring fault current limiter causing the designer to take a close look into the use of passive fault current limiter(FCL) for the protection of power semiconductor devices in power electronic systems. This paper has identified the main parameters responsible for the development of ideal passive magnetic current limiter. The effect of those parameters on the range of operation and the voltage-current characteristics of the magnetic current limiter has been studied using tableau approach. Desirable characteristics are discussed and the simulation results are presented.

  • PDF

Self-powered hybrid electromagnetic damper for cable vibration mitigation

  • Jamshidi, Maziar;Chang, C.C.;Bakhshi, Ali
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.285-301
    • /
    • 2017
  • This paper presents the design and the application of a new self-powered hybrid electromagnetic damper that can harvest energy while mitigating the vibration of a structure. The damper is able to switch between an energy harvesting passive mode and a semi-active mode depending on the amount of energy harvested and stored in the battery. The energy harvested in the passive mode resulting from the suppression of vibration is employed to power up the monitoring and electronic components necessary for the semi-active control. This provides a hybrid control capability that is autonomous in terms of its power requirement. The proposed hybrid circuit design provides two possible options for the semi-active control: without energy harvesting and with energy harvesting. The device mechanism and the circuitry that can drive this self-powered electromagnetic damper are described in this paper. The parameters that determine the device feasible force-velocity region are identified and discussed. The effectiveness of this hybrid damper is evaluated through a numerical simulation study on vibration mitigation of a bridge stay cable under wind excitation. It is demonstrated that the proposed hybrid design outperforms the passive case without external power supply. It is also shown that a broader force range, facilitated by decoupled passive and semi-active modes, can improve the vibration performance of the cable.

천음속 노즐에서 발생하는 응축충격파의 피동제어 (Passive Control of Condensation Shock Wave in a Transonic Nozzle)

  • 김희동;백승철;권순범
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.666-674
    • /
    • 2002
  • A rapid expansion of the moist air or stream through transonic nozzle often leads to not-equilibrium condensation shock, causing a considerable amount of energy loss to the entire flow field. Depending on amount of heat released, condensation shock wave occurs in the nozzle and interacts with the boundary layer flow. In the current study, a passive control technique using a porous wall with a plenum cavity underneath is applied for purpose of alleviation the condensation shock wave in a transonic nozzle. A droplet growth equation is incorporated into two-dimensional wavier-Stokes equation systems. Computations are carried out using a third-order MUSCL type TVD finite-difference scheme with a second-order fractional time step. An experiment using an indraft transonic wind tunnel is made to validate the present computational results. The results obtained show that the magnitude of condensation shock wave is reduced by the current passive control method.

신경회로망을 이용한 유연한 관절의 선단위치 tracking 제어기에 관한 실험적 평가 (Experimental Evaluation of Neural Network Based Controllers for Tracking the Tip Position of Flexible-Link)

  • 최부귀;이형기;박양수
    • 제어로봇시스템학회논문지
    • /
    • 제4권6호
    • /
    • pp.738-746
    • /
    • 1998
  • This paper presents a neural network-based adaptive controller for a single flexible-link. The control for feedback-error loaming of neural network is designed by using the re-definition approach. The neural network controllers are implemented on an single flexible-link experimental test-bed. The tip response is significantly improved and the vibrations of the flexible modes are damped very fast. Experimental and simulation results are presented of the proposed tip position tracking controllers over the conventional PD-type, passive controllers.

  • PDF

조립 로봇용 가변 수동 강성 장치의 설계 (Variable Passive Compliance Device for Robotic Assembly)

  • 김휘수;박동일;박찬훈;김병인;도현민;최태용;김두형;경진호
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.517-521
    • /
    • 2016
  • General industrial robots are difficult to use for precision assembly because they are operated based on position control. Their position accuracy is also usually higher than the assembly clearance (several tens of ${\mu}m$). In previous researches, force control was suggested as a robotic assembly solution. However, this method is difficult to apply in reality because of speed and cost problems. The RCC provides high speed, but applications are limited because the compliance is fixed, and it cannot detect an assembly condition during a task. A variable passive compliance device (VPCD) was developed herein. The VPCD can detect the assembly condition during tasks. This device can provide proper compliance for successful assembly tasks. The pneumatic system and the Stewart platform with an LVDT sensor were applied for measuring the displacement and variable compliance, respectively. The concept design and analysis were conducted to prove the effectiveness of the developed VPCD.

Design formulas for vibration control of sagged cables using passive MR dampers

  • Duan, Yuanfeng;Ni, Yi-Qing;Zhang, Hongmei;Spencer, Billie F. Jr.;Ko, Jan-Ming;Dong, Shenghao
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.537-551
    • /
    • 2019
  • In this paper, a method for analyzing the damping performance of stay cables incorporating magnetorheological (MR) dampers in the passive control mode is developed taking into account the cable sag and inclination, the damper coefficient, stiffness and mass, and the stiffness of damper support. Both numerical and asymptotic solutions are obtained from complex modal analysis. With the asymptotic solution, analytical formulas that evaluate the equivalent damping ratio of the sagged cable-damper system in consideration of all the above parameters are derived. The main thrust of the present study is to develop an general design formula and a universal curve for the optimal design of MR dampers for adjustable passive control of sagged cables. Two sag-affecting coefficients are derived to reflect the effects of cable sag on the maximum attainable damping ratio and the optimal damper coefficient. For the cable configurations commonly used in cable-stayed bridges, the sag-affecting coefficients are directly expressed in terms of the sag-extensibility parameter to facilitate the control design. A case study on adjustable passive vibration control of the longest cable (536 m) on Stonecutters Bridge is carried out to demonstrate the influence of the sag for the damper design, and to figure out the necessity of adjustability of damper coefficients for achieving maximum damping ratio for different vibration modes.

Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems

  • Kececioglu, O. Fatih;Acikgoz, Hakan;Yildiz, Ceyhun;Gani, Ahmet;Sekkeli, Mustafa
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.207-216
    • /
    • 2017
  • Wind energy conversion systems (WECS) which consist of wind turbines with permanent magnet synchronous generator (PMSG) and full-power converters have become widespread in the field of renewable power systems. Generally, conventional diode bridge rectifiers have used to obtain a constant DC bus voltage from output of PMSG based wind generator. In recent years, together advanced power electronics technology, Pulse Width Modulation (PWM) rectifiers have used in WECS. PWM rectifiers are used in many applications thanks to their characteristics such as high power factor and low harmonic distortion. In general, L, LC and LCL-type filter configurations are used in these rectifiers. These filter configurations are not exactly compensate current and voltage harmonics. This study proposes a hybrid passive filter configuration for PWM rectifiers instead of existing filters. The performance of hybrid passive filter was tested via MATLAB/Simulink environment under various operational conditions and was compared with LCL filter structure. In addition, neuro-fuzzy controller (NFC) was preferred to increase the performance of PWM rectifier in DC bus voltage control against disturbances because of its robust and nonlinear structure. The study demonstrates that the hybrid passive filter configuration proposed in this study successfully compensates current and voltage harmonics, and improves total harmonic distortion and true power factor.

반능동형 오리피스 유체댐퍼를 이용한 구조물 진동제어에 관한 실험적 연구 (An Experimental Study on the Structural Vibration Control Using Semi-Active Orificed Fluid Dampers)

  • 문석준;김병현;정종안
    • 한국지진공학회논문집
    • /
    • 제8권2호
    • /
    • pp.55-62
    • /
    • 2004
  • 최근 구조물 진동제어 연구분야에서는 반능동형 진동제어(제진)장치어 대한 연구가 활발하게 진행되고 있다. 반능동형 제진장치는 수동형의 장점인 신뢰성과 경제성 및 능동형의 장점인 적용성(순응성)을 얻을 수 있기 때문이다. 본 연구에서는 반능동형 제진장치의 일종으로 2톤급 반능동형 오리피스 유체댐퍼를 설계ㆍ제작하여 구조물의 적용을 통해 성능을 검증하였다. 수동형 오리피스 유체댐퍼에 2단 솔레노이드 밸브를 설치하여 반능동형을 구현하였다. 단독 성능시험을 통해 동특성을 파악하고, 시험용 철골구조물 적용시험을 통해 외부하중을 받는 구조물의 진동제어용 장치로서의 가능성을 확인하였다.

A calculation method of root loci band and its applications to robust control system design

  • Okuyama, Yoshifumi;Chen, Hong;Takemori, Fumiaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.350-353
    • /
    • 1994
  • This paper presents a method to calculate the characteristic root areas and loci band of control systems with uncertainties. First, equations of boundary curves of root areas in the case of additive and multiplicative perturbation are derived. Then, an algorithm for the calculation of the array of closed curves is presented. When the upper bound of the absolute values of frequency responses for the uncertain part, is also frequency-dependent, the frequency-dependent, terms are included in the characteristic equation of the nominal system. This lead to the boundary equations of the root, areas for control systems with frequency-dependent uncertainty. Numerical examples of the control systems with multiplicative perturbations including frequency-dependent terms are presented to verify this calculation method. Finally, its applications to the design of robust control systems, e.g., passive adaptive control systems are also discussed.

  • PDF