• Title/Summary/Keyword: particulate size

Search Result 467, Processing Time 0.023 seconds

Health effects of particulate matter (미세먼지의 건강영향)

  • Bae, Sanghyuk;Hong, Yun-Chul
    • Journal of the Korean Medical Association
    • /
    • v.61 no.12
    • /
    • pp.749-755
    • /
    • 2018
  • Particulate matter is an air pollutant emitted from both natural and anthropogenic sources, and its adverse health effects have been well documented in time-series analyses and cohort studies. The effect size of particulate matter exposure-a roughly 0.5% increase in mortality for each $10{\mu}g/m^3$ increment of short-term exposure to particulate matter with aerodynamic diameter ${\leq}10{\mu}m$ and approximately a 10% increase for each $10{\mu}g/m^3$ increment of long-term exposure to particulate matter with aerodynamic diameter ${\leq}2.5{\mu}m$-is small compared to other risk factors, but the exposure is involuntary and affects the entire population, which makes particulate matter pollution an important public health issue. The World Health Organization and Korean government have both established guidelines for particulate matter concentrations, but the Korean guideline is less stringent than that of the World Health Organization. The annual mean concentration of particulate matter in Korea is decreasing, but the trend seems to be slowing. In addition to policy efforts to reduce particulate matter emission, personal approaches such as the use of face masks and air purifiers have been recommended. Personal approaches may not solve the fundamental problem, but can provide temporary mitigation until efforts to reduce emission make progress.

Characteristic comparison of Andersen and total suspended particulate samplers in a particulate matter generation chamber (입자 발생 챔버를 이용한 Andersen과 총분진 시료채취기의 특성 비교)

  • Park, Ju-Myon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.177-184
    • /
    • 2008
  • The purpose of this study was to compare the performance characteristics of Andersen and total suspended particulate (TSP) samplers in terms of particle size distribution (PSD) and mass sampling efficiency. In the present study, two Andersen and four TSP samplers were selected and tested to quantitatively estimate human exposure to fly ash representing industrial particulate matter (PM) in a carefully controlled chamber. The PSD characteristics, a mass median aerodynamic diameter and a geometric standard deviation, were found from the sampled PM of airborne samplers in the chamber. An Andersen sampler was compared with a TSP sampler quantified by a coulter counter multisizer, as a reference sampler, to describe the correlation of mass sampling efficiencies between two types of samplers. Overall results indicate that Andersen samplers overestimated small PM due to particle bounce phenomena between impaction stages. There was reasonably good correlation ($R^2$ = 0.89 and 0.91) between the mass sampling efficiencies of Andersen and TSP samplers during the two tests. However, the lower values of slope (0.71 and 0.72) in two tests showed that the Andersen sampler underestimated PM (> AD $10.1\;{\mu}m$) with sufficient inertia due to a relatively lower Andersen inlet velocity at 0.8 m/s comparing with the operating air velocity at 2.1 m/s in the sampling zone of a chamber.

Comparative Study of Particulate Contamination from Ampoule and Prefilled Syringe (앰플 및 1회용 주사용기에서의 미립자 혼입에 관한 비교연구)

  • Shim, Chang-Koo;Han, Yong-Hae;Kwon, Don-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.3
    • /
    • pp.155-160
    • /
    • 1991
  • Particulate is the foreign insoluble material in injectable solution inadvertently present in a given product. Considerable efforts have been made to avoid or minimize particulate contamination by pharmaceutical manufacturers during the production of parenteral products. Particulate contamination of the parenteral products can occur mainly during the opening (cutting) the container immediately before clinical use. In this study, particulate contamination generated during the opening process of ampoules (conventional type, 1-point and color-break ampoules) was compared with that of a prefilled injectable container (prefilled syringe). The particles were examined under a microscope after filtration of the total fluids in the containers. Particles having wide range of size distribution were found from all the ampoules tested. The contamination from the I-point ampoule and colorbreak ampoule was much less than from the conventional ampoule. Glass particles generated by cutting the glass-made ampoules seemed a principal source of the particulate contamination. The glass-partiaulte contamination could be improved substantially by replacing the ampoule containers with the prefilled syringe. Prefilled syringe, which can be used without any cutting process. did not generate particulates during the use. Therefore, it was concluded that prefilled syringe is most preferable container for the small volume parenteral (SVP) fluids in terms of particulate contamination.

  • PDF

The Size Effect in Particulate Composite Materials - Size - Dependent Plasticity (입자보강 복합재료에서 크기효과 -Size-Dependent 소성역학)

  • Kim S. H.;Huh H.;Hahn H. Thomas
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.167-170
    • /
    • 2005
  • This paper briefly reviews various existing methods to account for the effect of particle size on mechanical properties of particulate metal matrix composites. A simple and easy method is to use a size-dependent constitutive equation for the matrix. The suggested method does not require the development of a new computational algorithm and is compatible with any standard finite element software. Finite element analyses have been carried out to show how the deformation behavior of a metal matrix composite changes as the particle size and volume fraction are varied.

  • PDF

Exhaust Emission Characteristics from Heavy-duty Diesel Engine applicable to Prime Propulsion Engine for Marine Vessels (선박 주 추진기관으로 사용가능한 대형 디젤엔진의 배기가스 특성 분석)

  • Lee, Hyung-Min;Park, Rang-Eun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.484-489
    • /
    • 2012
  • The objective of this work presented here was focused on analysis of particulate matter and nitrogen oxide characteristics in ESC test mode from heavy-duty diesel engine installed on-road vehicles applicable to prime propulsion engine for marine vessels. The authors confirmed that a large quantity particulate matter were emitted in high power density condition, nitrogen oxide characteristics were dependent on exhaust gas temperature. Particulate matters were reduced by 1/100~1/1,000 times in post DPF with test modes but filtration efficiency was decreased in the engine power fluctuation. In the case of the high speed and power condition, the exhaust level of particulate matters was increased according to increment of temperature of gas flowing into DPF. The orders of magnitude for particle concentration levels from the analysis of size distribution of particulate matters of test engine was different. Both emitting nano-sized particles below 100nm regardless of DPF and non-DPF.

Particle size distributions and concentrations above radiators in indoor environments: Exploratory results from Xi'an, China

  • Chen, Xi;Li, Angui
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.237-245
    • /
    • 2015
  • Particulate matter in indoor environments has caused public concerns in recent years. The objective of this research is to explore the influence of radiators on particle size distributions and concentrations. The particle size distributions as well as concentrations above radiators and in the adjacent indoor air are monitored in forty-two indoor environments in Xi'an, China. The temperatures, relative humidity and air velocities are also measured. The particle size distributions above radiators at ten locations are analyzed. The results show that the functional difference of indoor environments has little impact on the particle size distributions above radiators. Then the effects of the environmental parameters (particle concentrations in the adjacent indoor air, temperatures, relative humidities and air velocities) on particle concentrations above radiators are assessed by applying multiple linear regression analysis. Three multiple linear regression models are established to predict the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_1$ above radiators.

Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area (수원지역 입자상 오염물질의 오염원 기여도의 추정)

  • 이태정;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF

Size Distribution of Water-Soluble Ionic Components in the Atmospheric Aerosols Collected in Jeju City, Korea (제주시 대기부유부진 중 수용성 이온성분의 입경별 분포특성)

  • Hu Chul-Goo;Song Jeong-Hwa;Lee Ki-Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1067-1078
    • /
    • 2004
  • Atmospheric particulate matters were collected by 8-stage non viable cascade impactor from October 2002 to August at Jeju City. Eight water-soluble ionic components $(Na^+,\;NH_{4}_{+},\;K^+,\;Ca{2+},\;Mg^{2+},\;CI^-,\;NO_{3}^-\;and\;SO_{4}^{2-})$ were analyzed by Ion Chromatography. The concentration of particulate matters and eight water-soluble ionic components were determined to investigate their size distributions. Particulate matters exhibited a tri-modal distribution with peak value around $0.9,\;4.0{\mu}m\;and\;9.5{\mu}m.$ In summer, the last peak value was lower than other season values likely due to particulate matter scavenged by rain water. Four ionic components $(Na^+,\;Ca^{2+},\;Mg^{2+}\;and\;CI^-)$ exhibited a bi-modal distribution in the coarse mode whereas three ionic components $(NH_{4}^+,\;K^+\;and\;SO_{4}^{2-})$ in the fine mode, with maximum peak value around $0.9{\mu}m.\;NO_{3}^-$ was found in both the coarse and the fine mode. The enrichment factor (E.F.) of each ionic components was calculated. Based upon E.F., it is considered that $Na^+,\;CI^-,\;and\;K^+$ in coarse paricle mode were delivered form oceanic source, but other components might have other source origins.

Effect of Dispersion Stability of Particles on Detergency of Particulate Soil(Part 1) - The Dispersion Stability of α-Fe2O3 Particles in the Nonyl Phenol Polyoxyethylene Ether Solution - (입자의 분산안정성이 고형오구의 세척성에 미치는 영향(제1보) - Nonyl Phenol Polyoxyethylene Ether 용액 내에서 α-Fe2O3 입자의 분산안정성 -)

  • Kang, In-Sook
    • Fashion & Textile Research Journal
    • /
    • v.4 no.1
    • /
    • pp.86-91
    • /
    • 2002
  • To estimate dispersion stability of particles, suspending power and particle size were examined as functions of pHs, surfactants, electrolytes and ionic strengths using ${\alpha}-Fe_2O_3$ particle as the model of particulate soil. Suspending power and particle size were determined by UV-Vis spectrumeter and by light scattering using the polarization ratio method, respectively. The suspending power was relatively high with polyanion electrolytes and was low with neutral salts. The suspending power was biphasis, minimum pH 6~7, and the effect of surfactant on the suspending power was insignificant. Generally suspending power increased with decreasing the particle size governed aggregation of dispersed particles regardless of solution conditions. Hence the suspending power was inversely related to the particle size.