• Title/Summary/Keyword: particulate

Search Result 2,893, Processing Time 0.037 seconds

A Particulate Matter Sensor with Groove Electrode for Real-Time Diesel Engine On-Board Diagnostics

  • Kim, S.;Kim, Y.;Lee, J.;Lim, S.;Min, K.;Chun, K.
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • A particulate matter sensor fabricated by MEMS process is proposed. It is developed to accommodate Euro6 on-board diagnostics regulation for diesel automobile. In the regulation, emission of diesel particulate matter is restricted to 9 mg/km. Particulate matter sensor is designed to use induced charges by charged particulate matter. To increase sensitivity of the sensor, groove is formed on sensor surface because wider surface area generates more induced charges. Sensitivity of the sensor is measured 10.6 mV/(mg/km) and the sensor shows good linearity up to 15.7 mg/km. Also its minimum detectable range is about 0.25 mg/km. It is suitable to detect failure of a diesel particulate filter which should filter particulate matter more than 9 mg/km. For removing accumulated particulate matter on the sensor which can disturb normal operation, platinum heater is designed on the backside of the sensor. The developed sensor can sense very low amount of particulate matter from exhaust gas in real-time with good linearity.

Formation of particulate-phase and gas-phase polycyclic aromatic hydrocarbons in cigarette smoke

  • Shimazu, Haruki;Yata, Tsuyoshi;Ozaki, Naoto
    • Advances in environmental research
    • /
    • v.6 no.3
    • /
    • pp.189-202
    • /
    • 2017
  • This study examines the concentrations of particulate-phase polycyclic aromatic hydrocarbons (PAHs) and gas-phase PAHs in sidestream cigarette smoke. Sixteen PAHs were determined for four brands of cigarettes. The volume of the experimental room is approximately $66m^3$. The air samples in the room were collected before and after smoking. The median total of particulate-phase and gas-phase PAH concentrations before smoking $3.13ng/m^3$and $48.0ng/m^3$, respectively. The median concentrations of them after smoking were $10.0ng/m^3$ and $79.6ng/m^3$. The median increases in the total of 16 PAH concentrations per cigarette during smoking were 271 ng for the particulate-phase PAHs and 1960 ng for the gas-phase PAHs. According to the relationship between particulate-phase and gas-phase PAHs after smoking, the two- to four-ring gas-phase PAHs and the higher molecular weight particulate-phase PAHs were probably formed from similar precursors. The relationship between the total suspended particulate (TSP) concentration and the increase in the total particulate-phase concentration of the 16 PAHs per cigarette during smoking were significantly positive. The increase in the total gas-phase concentration of the 16 PAHs tended to increase as the TSP concentration increased. This may indicates that decreasing the amount of TSP produced inhibit the production of PAHs during smoking.

Health effects of particulate matter (미세먼지의 건강영향)

  • Bae, Sanghyuk;Hong, Yun-Chul
    • Journal of the Korean Medical Association
    • /
    • v.61 no.12
    • /
    • pp.749-755
    • /
    • 2018
  • Particulate matter is an air pollutant emitted from both natural and anthropogenic sources, and its adverse health effects have been well documented in time-series analyses and cohort studies. The effect size of particulate matter exposure-a roughly 0.5% increase in mortality for each $10{\mu}g/m^3$ increment of short-term exposure to particulate matter with aerodynamic diameter ${\leq}10{\mu}m$ and approximately a 10% increase for each $10{\mu}g/m^3$ increment of long-term exposure to particulate matter with aerodynamic diameter ${\leq}2.5{\mu}m$-is small compared to other risk factors, but the exposure is involuntary and affects the entire population, which makes particulate matter pollution an important public health issue. The World Health Organization and Korean government have both established guidelines for particulate matter concentrations, but the Korean guideline is less stringent than that of the World Health Organization. The annual mean concentration of particulate matter in Korea is decreasing, but the trend seems to be slowing. In addition to policy efforts to reduce particulate matter emission, personal approaches such as the use of face masks and air purifiers have been recommended. Personal approaches may not solve the fundamental problem, but can provide temporary mitigation until efforts to reduce emission make progress.

Studies on the Seasonal Variations of Plankton Organisms and Suspended Particulate Matter in the Coastal Area of Ko-Ri

  • Choe, Sang
    • 한국해양학회지
    • /
    • v.7 no.2
    • /
    • pp.47-58
    • /
    • 1972
  • Densities and composition of phytoplankton and zooplankton, concentrations of particulate organic carbon, particulate organic nitrogen, and particulate inorganic matter were determined in the coastal area of Ko-ri during one year. There are peaks of densities of plankton organisms in summer, autumn, and spring Concentrations of particulate organic carbon ranged from 35 to 3,785 mg/㎥ (averaging 868mg/㎥ ), particulate organic nitrogen ranged from 4.4 to 158mg/㎥ (averaging 45mg/㎥), inorganic suspended matter ranged from 0.6 to 11.6 mg/L (averaging 5.7mg/L), and the carbon-nitrogen ratios of the suspended matter were varied from 0.5 to 231(averaging 35), with each seasonal cycle. The phytoplankton density and particulate organic carbon were possitively correlated from March to November, negatively from December to February, and the zooplankton dinsity and particulate organic nitrogen were well correlated.

  • PDF

Compressive rheology of aggregated particulate suspensions

  • Gladman Brendan;Usher Shane P.;Scales Peter J.
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.4
    • /
    • pp.191-197
    • /
    • 2006
  • The measurement of the compressional rheological parameters for an aggregated particulate suspension is described. The parameters include the compressive yield stress and hindered settling function, describing the extent and rate of dewatering respectively. The variation of these parameters with shear rate and time of shear is also considered in the light of their sensitivity to low shear rates, with particular reference to the case of flocculated particulate suspensions. The latter is seen to be important in the future development of a comprehensive understanding of compressive rheology of aggregated particulate suspensions in industrial applications such as thickening, filtration and centrifugation.

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

Comparative Study of Particulate Contamination from Ampoule and Prefilled Syringe (앰플 및 1회용 주사용기에서의 미립자 혼입에 관한 비교연구)

  • Shim, Chang-Koo;Han, Yong-Hae;Kwon, Don-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.3
    • /
    • pp.155-160
    • /
    • 1991
  • Particulate is the foreign insoluble material in injectable solution inadvertently present in a given product. Considerable efforts have been made to avoid or minimize particulate contamination by pharmaceutical manufacturers during the production of parenteral products. Particulate contamination of the parenteral products can occur mainly during the opening (cutting) the container immediately before clinical use. In this study, particulate contamination generated during the opening process of ampoules (conventional type, 1-point and color-break ampoules) was compared with that of a prefilled injectable container (prefilled syringe). The particles were examined under a microscope after filtration of the total fluids in the containers. Particles having wide range of size distribution were found from all the ampoules tested. The contamination from the I-point ampoule and colorbreak ampoule was much less than from the conventional ampoule. Glass particles generated by cutting the glass-made ampoules seemed a principal source of the particulate contamination. The glass-partiaulte contamination could be improved substantially by replacing the ampoule containers with the prefilled syringe. Prefilled syringe, which can be used without any cutting process. did not generate particulates during the use. Therefore, it was concluded that prefilled syringe is most preferable container for the small volume parenteral (SVP) fluids in terms of particulate contamination.

  • PDF

Particulate Matter Prediction Model using Artificial Neural Network (인공 신경망을 이용한 미세먼지 예측 모델)

  • Jung, Yong-jin;Cho, Kyoung-woo;Kang, Chul-gyu;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.623-625
    • /
    • 2018
  • As the issue of particulate matter spreads, services for providing particulate matter information in real time are increasing. However, when a sensor node for collecting particulate matter is defective, a corresponding service may not be provided. To solve these problems, it is necessary to predict and deduce particulate matter. In this paper, a particulate matter prediction model is designed using artificial neural network algorithm based on past particulate matter and meteorological data to predict particulate matter. Also, the prediction results are compared by learning the input data of the model in the design stage.

  • PDF

Particulate Matter AQI Index Prediction using Multi-Layer Perceptron Network (다층 퍼셉트론 신경망을 이용한 미세먼지 AQI 지수 예측)

  • Cho, Kyoung-woo;Lee, Jong-sung;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.540-542
    • /
    • 2019
  • With many announcements on air pollution and human effects from particulate matters, particulate matter forecasts are attracting a lot of public attention. As a result, various efforts have been made to increase the accuracy of particulate matter forecasting by using statistical modeling and machine learning technique. In this paper, the particulate matter AQI index prediction is performed using the multilayer perceptron neural network for particulate matter prediction. For this purpose, a prediction model is designed by using the meteorological factors and particulate matter concentration values commonly used in a number of studies, and the accuracy of the particulate matter AQI prediction is compared.

  • PDF

A Study on the Local Particulate Matter Monitoring Technology using Shared-Use Mobilities for Metaverse Reality (메타버스 리얼리티를 위한 공유 모빌리티 기반 국부적 미세먼지 관측 기술 연구)

  • Jung, In Taek;Jang, Bong-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.8
    • /
    • pp.1138-1148
    • /
    • 2021
  • In this study, we developed a 'shared-use mobility'-mounted local particulate matter monitoring terminal technology to measure the actual particulate matter concentration around me. As a mobile terminal device in the form of an IoT sensor platform, it is designed to be separated into a control module and a sensor module to minimize interference between sensors and to consider the optimal observation position of each sensor. As a result of the field test, it was confirmed that particulate matter was locally different depending on time and space even within the same area. In addition, it was confirmed that the concentration of particulate matter in the relevant section differed by up to 100 times compared to the surrounding area due to specific sources of particulate matter such as unpaved roads. In addition, we positively reviewed the applicability of the service in the real-time metaverse environment using this result. Through technological advancement and application of multiple shared-use mobilities, we expect to be able to provide new services for practical smart city air environment monitoring, such as localized particulate matter information, air pollution event information, and identification of causes of particulate matter.