• Title/Summary/Keyword: particle system

Search Result 2,942, Processing Time 0.041 seconds

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

The Study of PM10, PM2.5 Mass Extinction Efficiency Characteristics Using LIDAR Data (라이다 데이터를 이용한 PM10, PM2.5 질량소산효율 특성 연구)

  • Kim, TaeGyeong;Joo, Sohee;Kim, Gahyeong;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_2
    • /
    • pp.1793-1801
    • /
    • 2021
  • From 2015 to June 2020, the backscattering coefficients of 532 and 1064 nm measured using LIDAR and the depolarization ratio at 532 nm were used to separate the backscattering coefficient at 532 nm as three types as PM10, PM2.5-10, PM2.5 according to particle size. The mass extinction efficiency (MEE) of three types was calculated using the mass concentration measured on the ground. The overall mean values of the calculated MEE were 5.1 ± 2.5, 1.7 ± 3.7, and 9.3 ± 6.3 m2/g in PM10, PM2.5-10, and PM2.5, respectively. When the mass concentration of PM10 and PM2.5 was low, higher than average MEE was calculated, and it was confirmed that the MEE decreased as the mass concentration increased. When the MEE was calculated for each type according to the mixing degree of Asian dust, PM2.5-10 was twice at pollution aerosol as high as 2.1 ± 2.8 m2/g, compare to pollution-dominated mixture, dust-dominated mixture, and pure dust of 1.1 ± 1.8, 1.4 ± 3.3, 1.1 ± 1.5 m2/g, respectively. However, PM2.5 MEE showed similar values irrespective of type: 9.4 ± 6.5, 9.0 ± 5.8, 10.3 ± 7.5, and 9.1 ± 9.0 m2/g. The MEE of PM10 was 5.6 ± 2.9, 4.4 ± 2.0, 3.6 ± 2.9, and 2.8 ± 2.4 m2/g in pollution aerosol (PA), pollution-dominated mixture (PDM), dust-dominated mixture (DDM), and pure dust (PD), respectively, and increased as the dust ratio value decreased. Even if the same type according to the same mass concentration or Asian dust mixture was shown, as the PM2.5/PM10 ratio decreased, the MEE of PM2.5-10 decreased and the MEE of PM2.5 showed a tendency to increase.

Quality Characteristics and Antioxidant Activity of Black Soybean Sunsik Product with Functional Food Ingredients and Functional Labeling System (기능성 원료를 첨가하여 기능성 표시제도를 적용한 검은콩 선식 제품의 품질 특성 및 항산화활성)

  • Lee, Kang-Pyo;In, Ye-Won;Lim, June seok;Cho, Geun hee;Lee, Ok-Hwan;Lee, Boo-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.339-346
    • /
    • 2022
  • This study was performed to investigate the quality characteristics and antioxidant activity of black soybean Sunsik product with functional food ingredients and functional labeling system. We prepared black soybean Sunsik (BS) containing black beans, cereals, and vegetables. Black soybean Sunsik with nondigestible maltodextrin and calcium lactate (BSN) was prepared by adding non-digestible maltodextrin and calcium lactate to the base recipe to apply a functional labeling system. The particle size in BS was 118.00 ㎛, whereas BSN was 127.00 ㎛. The respective L, a, and b color values of BS were 73.25, 2.36, and 14.21. The respective L, a, and b values of BSN were 73.21, 2.36, and 14.31. The respective water retention capacities of BS and BSN were 241.67% and 216.33%. No significant difference was observed between BS and BSN in the three physicochemical properties described above. However, the pH of BSN was 5.45, which was significantly lower than that of BS. The total respective phenolic contents of BS and BSN were 1.75 mg GAE/g and 1.61 mg GAE/g, and total respective flavonoid contents of BS and BSN were 6.36 mg RE/g and 5.95 mg RE/g. The antioxidant capacities of BS and BSN were compared via assays of DPPH and ABTS radical scavenging activities, FRAP, and reducing power. The antioxidant activities of BS and BSN increased in a dose-dependant manner. No significant difference between BS and BSN was observed in any measure of antioxidant capacity. These results suggested that the addition of functional food ingredients (non-digestible maltodextrin and calcium lactate) did not affect the quality characteristics and antioxidant activity of black soybean Sunsik.

LC-MS/MS analysis and anti-inflammatory effects of crude extract from Coptidis Rhizoma (황련 추출물의 LC-MS/MS 분석 및 항염증 효과)

  • Min-Jung, Kim;Ye-Jin, Yang;Kwang-Youn, Kim;Hun Hwan, Kim;Jae Dong, Son;Ju-Hye, Yang;Dong bin, Lee;Woo Hyun, Kim;Hu-Jang, Lee;Seon Been, Bak;Kwang-Il, Park
    • Herbal Formula Science
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Objectives : The main aim of this study was to examine the LC-MS/MS used to identify phenolic compounds of CRE(Coptidis Rhizoma 70% EtOH Extract). Also, we investigated antioxidative activities and Anti-inflammatory activities. Methods : LC-MS/MS Analysis HPLC and LC-MS/MS were performed on a 1260 series HPLC system (Agilent Technologies, Inc., California, USA) and 3200 QTrap tandem mass system (Sciex LLC) operated in positive ion mode (spray voltage set at -4.5 kV). The solvent used was DW and Acetonitrile containing 0.1% formic acid, a gradient system was used at a flow rate of 0.5 mL/min for analysis, and a Prontosil C18 column (length, 250 mm; inner diameter, 4.6 mm; particle size, 5 ㎛; Phenomenex Co., Ltd., California, USA, Biochoff Chromatography) was used. The solvent conditions used in the mobile phases were 0-10 min at 10-15% B, 10-20 min at 20% B, 20-30 min at 25%, 30-40 min at 40%, 40-50 min at 70%, 50-60 min at 95%, and 60-70 min at 95%. The analysis was performed at a wavelength of 284 nm and a temperature of 35℃. The cell viability was measured using a 3-(4,5-dimethyethiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity. We examined the effects of CRE on the lipopolysaccharide (LPS)-induced production of nitric oxide (NO) in a RAW 264.7 cells Results : The chemical analysis CRE by Liquid chromatography-tandem mass spectrometry (LC-MS/MS) confirmed that Rosmarinic acid, Ferrulic acid, 3-O-feruloylquinic acid, and 5-O-feruloylquinic acid as phenolic components. DPPH radical scavenging activity was the inhibitory activity of CRE showed at 200 ㎍/mL a statistically significant level. MTT assay demonstrated that the CRE did not have a cytotoxic effect in RAW 264.7 and LPS-induced RAW264.7 cells. Also, CRE reduced NO production in RAW 264.7 cells stimulated with LPS. Conclusions : Based on these findings, The chemical analysis 4 major components CRE such as Rosmarinic acid, Ferrulic acid, 3-O-feruloylquinic acid, and 5-O-feruloylquinic acid. Moreover, we confirmed that CRE has effects antioxidant and anti-inflammatory. The results demonstrate that CRE can be used as an antioxidant and a powerful chemopreventive ingredient against inflammatory diseases.

Preparation of Vitamin E Acetate Nano-emulsion and In Vitro Research Regarding Vitamin E Acetate Transdermal Delivery System which Use Franz Diffusion Cell (Vitamin E Acetate를 함유한 Nano-emulsion 제조와 Franz Diffusion Cell을 이용한 Vitamin E Acetate의 경표피 흡수에 관한 In Vitro 연구)

  • Park, Soo-Nam;Kim, Jai-Hyun;Yang, Hee-Jung;Won, Bo-Ryoung;Ahn, You-Jin;Kang, Myung-Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.2
    • /
    • pp.91-101
    • /
    • 2009
  • in the cosmetics and medical supply field as a antioxidant material. The stable nano particle emulsion of skin toner type containing VEA was prepared. To evaluate the skin permeation, experiments on VEA permeation to the skin of the ICR outbred albino mice (12 weeks, about 50 g, female) and on differences of solubility as a function of receptor formulations was performed. The analysis of nano-emulsions containing VEA 0.07 % showed that the higher ethanol contents the larger emulsions were formed, while the higher surfactant contents the size became smaller.In this study, vitamin E acetate (VEA, tocopheryl acetate), a lipid-soluble vitamin which is widely used A certain contents of ethanol in receptor phase increased VEA solubility on the nano-emulsion. When the ethanol contents were 10.0 % and 20.0 %, the VEA solubility was higher than 5.0 % and 40.0 %, respectively. The type of surfactant in receptor solution influenced to VEA solubility. The comparison between three kind surfactants whose chemical structures and HLB values are different, showed that solubility of VEA was increased as order of sorbitan sesquioleate (Arlacel 83; HLB 3.7) > POE (10) hydrogenated castor oil (HCO-10; HLB 6.5) > sorbitan monostearate (Arlacel 60; HLB 4.7). VEA solubility was also shown to be different according to the type of antioxidant. In early time, the solubility of the sample including ascorbic acid was similar to those of other samples including other types of antioxidants. However, the solubility of the sample including ascorbic acid was 2 times higher than others after 24 h. Franz diffusion cell experiment using mouse skin was performed with four nano-emulsion samples which have different VEA contents. The emulsion of 10 wt% ethanol was shown to be the most permeable at the amount of 128.8 ${\mu}g/cm^2$. When the result of 10 % ethanol content was compared with initial input of 220.057 ${\mu}g/cm^2$, the permeated amount was 58.53 % and the permeated amount at 10 % ethanol was higher 45.0 % and 15.0 % than the other results which ethanol contents were 1.0 and 20.0 wt%, respectively. Emulsion particle size used 0.5 % surfactant (HCO-60) was 26.0 nm that is one twentieth time smaller than the size of 0.007 % surfactant (HCO-60) at the same ethanol content. Transepidermal permeation of VEA was 54.848 ${\mu}g/cm^2$ which is smaller than that of particlesize 590.7 nm. Skin permeation of nano-emulsion containing VEA and difference of VEA solubility as a function of receptor phase formulation were determined from the results. Using these results, optimal conditions of transepidermal permeation with VEA were considered to be set up.

Development of Three-Dimensional Trajectory Model for Detecting Source Region of the Radioactive Materials Released into the Atmosphere (대기 누출 방사성물질 선원 위치 추적을 위한 3차원 궤적모델 개발)

  • Suh, Kyung-Suk;Park, Kihyun;Min, Byung-Il;Kim, Sora;Yang, Byung-Mo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.31-39
    • /
    • 2016
  • Background: It is necessary to consider the overall countermeasure for analysis of nuclear activities according to the increase of the nuclear facilities like nuclear power and reprocessing plants in the neighboring countries including China, Taiwan, North Korea, Japan and South Korea. South Korea and comprehensive nuclear-test-ban treaty organization (CTBTO) are now operating the monitoring instruments to detect radionuclides released into the air. It is important to estimate the origin of radionuclides measured using the detection technology as well as the monitoring analysis in aspects of investigation and security of the nuclear activities in neighboring countries. Materials and methods: A three-dimensional forward/backward trajectory model has been developed to estimate the origin of radionuclides for a covert nuclear activity. The developed trajectory model was composed of forward and backward modules to track the particle positions using finite difference method. Results and discussion: A three-dimensional trajectory model was validated using the measured data at Chernobyl accident. The calculated results showed a good agreement by using the high concentration measurements and the locations where was near a release point. The three-dimensional trajectory model had some uncertainty according to the release time, release height and time interval of the trajectory at each release points. An atmospheric dispersion model called long-range accident dose assessment system (LADAS), based on the fields of regards (FOR) technique, was applied to reduce the uncertainties of the trajectory model and to improve the detective technology for estimating the radioisotopes emission area. Conclusion: The detective technology developed in this study can evaluate in release area and origin for covert nuclear activities based on measured radioisotopes at monitoring stations, and it might play critical tool to improve the ability of the nuclear safety field.

A Study on the dose distribution produced by $^{32}$ P source form in treatment for inhibiting restenosis of coronary artery (관상동맥 재협착 방지를 위한 치료에서 $^{32}$ P 핵종의 선원 형태에 따른 선량분포에 관한 연구)

  • 김경화;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the dose distributions of a $^{32}$ p uniform cylindrical volume source and a surface source, a pure $\beta$emitter, were calculated in order to obtain information relevant to the utilization of a balloon catheter and a radioactive stent. The dose distributions of $^{32}$ p were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly in the volume and on the surface in the form of a cylinder with a radius of 1.5 mm and length of 20 mm. The energy of $\beta$particles emitted is chosen at random in the $\beta$ energy spectrum evaluated by the solution of the Dirac equation for the Coulomb potential. Liquid water is used to simulate the particle transport in the human body. The dose rates in a target at a 0.5mm radial distance from the surface of cylindrical volume and surface source are 12.133 cGy/s per GBq (0.449 cGy/s per mCi, uncertainty: 1.51%) and 24.732 cGy/s per GBq (0.915 cGy/s per mCi, uncertainty: 1.01%), respectively. The dose rates in the two sources decrease with distance in both radial and axial direction. On the basis of the above results, the determined initial activities were 29.69 mCi and 1.2278 $\mu$Ci for the balloon catheter and the radioactive stent using $^{32}$ P isotope, respectively. The total absorbed dose for optimal therapeutic regimen is considered to be 20 Gy and the treatment time in the case of the balloon catheter is less than 3 min. Absorbed doses in targets placed in a radial direction for the two sources were also calculated when it expressed initial activity in a 1 mCi/ml volume activity density for the cylindrical volume source and a 0.1 mCi/cm$^2$ area activity density for the surface source. The absorbed dose distribution around the $^{32}$ P cylindrical source with different size can be easily calculated using our results when the volume activity density and area activity density for the source are known.

  • PDF

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.