• Title/Summary/Keyword: particle size effect

Search Result 1,969, Processing Time 0.024 seconds

Feasibility Study on the Optimization of Offsite Consequence Analysis by Particle Size Distribution Setting and Multi-Threading (입자크기분포 설정 및 멀티스레딩을 통한 소외사고영향분석 최적화 타당성 평가)

  • Seunghwan Kim;Sung-yeop Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.1
    • /
    • pp.96-103
    • /
    • 2024
  • The demand for mass calculation of offsite consequence analysis to conduct exhaustive single-unit or multi-unit Level 3 PSA is increasing. In order to perform efficient offsite consequence analyses, the Korea Atomic Energy Research Institute is conducting model optimization studies to minimize the analysis time while maintaining the accuracy of the results. A previous study developed a model optimization method using efficient plume segmentation and verified its effectiveness. In this study, we investigated the possibility of optimizing the model through particle size distribution setting by checking the reduction in analysis time and deviation of the results. Our findings indicate that particle size distribution setting affects the results, but its effect on analysis time is insignificant. Therefore, it is advantageous to set the particle size distribution as fine as possible. Furthermore, we evaluated the effect of multithreading and confirmed its efficiency. Future optimization studies should be conducted on various input factors of offsite consequence analysis, such as spatial grid settings.

Effect of the WC particle size and Co content on the adhesion property between AIP-TiN coating and WC-Co substrate (AIP-TiN/WC-Co계에서 WC입자크기와 Co함량이 밀착력에 미치는 영향)

  • 한대석;류정민;권식철;김광호
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.3
    • /
    • pp.165-171
    • /
    • 2002
  • TiN coating were deposited onto different WC-Co substrates using arc ion plating (AIP) technique. The structure and morphology for the deposited coating were characterized by x-ray diffraction (XRD) and scanning electron microscopy (SEM). The adhesion behavior of the deposited TiN coating was investigated with a conventional scratch test. Effects of WC particle size and Co content on the adhesion strength between the deposited TiN coating and substrate were studied. During the scratch test, the value of critical load was dependent of WC particle size and Co content on substrate. As the WC particle size and Co content on substrate decreased, the critical load increased. The highest critical load, approximately 110N, was obtained at WC particle size of 1$\mu\textrm{m}$ and Co content of 10wt.%.

Effect of particle size on graphite reinforced conductive polymer composites (입자의 크기에 따른 흑연 보강 전도성 고분자 복합재료의 특성 연구)

  • Heo, S.I.;Yun, J.C.;Oh, K.S.;Han, K.S.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.257-260
    • /
    • 2005
  • Graphite reinforced conductive polymer composites were fabricated by the compression molding technique. Graphite powder was mixed with an phenol resin to impart electrical property in composites. The ratio and particle size of graphite powder were varied to investigate electrical conductivity of cured composites. In this study, graphite reinforced conductive polymer composites with high filler loadings(>66wt.%) were manufactured to accomplish high electrical conductivity. With increasing the loading ratio of graphite powder, the electrical conductivity and flexural strength increased. However. above 80wt.% filler loadings, flexural strength decreased due to lack of resin. Regardless of graphite particle size, electrical conductivity wasn’t varied. On the other hand, with decreasing particle size, flexural strength increased due to high specific surface area.

  • PDF

Effects of Particle Size of Barley on Intestinal Morphology, Growth Performance and Nutrient Digestibility in Pigs

  • Morel, P.C.H.;Cottam, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1738-1745
    • /
    • 2007
  • A growth trial and a digestibility trial were conducted to examine the effect of feed particle size on the performance, nutrient digestibility, gastric ulceration and intestinal morphology in pigs fed barley-based diets. Barley was processed through a hammer mill to achieve four diets varying in particle size (average particle $size{\pm}standard $deviation): coarse ($1,100{\pm}2.19\;{\mu}m$), medium ($785{\pm}2.23\;{\mu}m$), fine ($434{\pm}1.70\;{\mu}m$) and mixed (1/3 of coarse, medium and fine) ($789{\pm}2.45\;{\mu}m$). Sixty-four entire male pigs were used in the growth trial and the diets were fed ad libitum between 31 kg and 87 kg live weight. Following slaughter, stomach and ileal tissues were scored for integrity (ulceration or damage) and histological measurements taken. Twenty-four entire male pigs were used in the digestibility trial, which involved total faecal collection. Over the entire growth phase, there were no differences (p>0.05) in average daily gain and feed conversion ratio between pigs fed diets of different particle size. Pigs fed the coarse and medium diets had lower (p<0.05) stomach ulceration scores (0.20 and 0.25, respectively, on a scale from 0 to 3) than those fed the mixed (0.69) or the fine diets (1.87). The stomachs of all animals fed the fine diet had lesions and stomach ulcerations were present only in this group. Pigs fed the fine diet had thicker (p<0.001) ileal epithelial cell layer with no differences (p>0.05) being observed for villous height or crypt depth. Faecal digestibility coefficients of neutral and acid detergent fibre were the highest (p<0.05) for the mixed diet, intermediate for the fine and coarse diets and the lowest for the medium diet. A similar numerical trend (p = 0.103) was observed for the apparent faecal energy digestibility coefficient. It is concluded that, with barley based diets, a variation in average particle size between $400{\mu}m$ and $1,100{\mu}m$ had no effect on pig performance but the fine dietary particle size affected the integrity of the stomach, as well as the structure of the small intestine, thus compromising overall gut health. Our data also demonstrate that changes in particle size distribution during the digestion process, rather than average particle size or particle size variation, are related to apparent faecal digestibility.

Effect of Nozzle Tip Size on the Fabrication of Nano-Sized Nickel Oxide Powder by Spray Pyrolysis Process

  • Kim, Donghee;Yu, Jaekeun
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.489-494
    • /
    • 2013
  • In this study, by using nickel chloride solution as a raw material, a nano-sized nickel oxide powder with an average particle size below 50 nm was produced by spray pyrolysis reaction. A spray pyrolysis system was specially designed and built for this study. The influence of nozzle tip size on the properties of the produced powder was examined. When the nozzle tip size was 1 mm, the particle size distribution was more uniform than when other nozzle tip sizes were used and the average particle size of the powder was about 15 nm. When the nozzle tip size increases to 2 mm, the average particle size increases to roughly 20 nm, and the particle size distribution becomes more uneven. When the tip size increases to 3 mm, particles with an average size of 25 nm and equal to or less than 10 nm coexist and the particle size distribution becomes much more uneven. When the tip size increases to 5 mm, large particles with average size of 50 nm partially exist, mostly consisting of minute particles with average sizes in the range of 15~25 nm. When the tip size increases from 1 mm to 2 mm, the XRD peak intensities greatly increase while the specific surface area decreases. When the tip size increases to 3 mm, the XRD peak intensities decrease while the specific surface area increases. When the tip size increases to 5 mm, the XRD peak intensities increase again while the specific surface area decreases.

The Effect of the Varieties and Particle Size on the Properties of Rice Flour (품종 및 입자크기가 쌀가루의 특성에 미치는 영향)

  • Kum, Jun-Seok;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1542-1548
    • /
    • 1999
  • Seven rice varieties(Suweonjo, Suweon232, BG276-5, IR44, IR41999-139, Suweon230 and Yongjubyeo) were used to study the effect of particle size on the physicochemical properties(proximate analysis, color values, amylogram, water absorption index and water solubility index) of rice flours. Suweonjo had the highest amylose content (27.07%) and Yongjubyeo had the lowest one (17.17%). Suweonjo had the highest protein content (11.36%) and IR44 had the lowest one (6.75%). Protein content of rice flours prepared in a pin mill was decreased as particle size of rice flours decreased. L value of rice flour was increased as particle size of rice flours decreased while b value and ${\Delta}E$ value decreased. Maximum viscosity, cold paste viscosity, breakdown, total setback in amylogram properties were increased as particle size of rice flours decreased while initial paste temperature decreased. Water absorption index (WAI) and water solubility index (WSI) were increased as particle size of rice flour decreased.

  • PDF

Effect of Slag Particle Size and Volume Fraction on Mechanical Properties of Slag Reinforced Composite (슬래그 입자의 크기 및 체적비에 따른 슬래그 입자강화 복합재료의 기계적 특성 연구)

  • Nam, Ji-Hoon;Chun, Heoung-Jae;Hong, Ik-Pyo
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.218-222
    • /
    • 2013
  • This study demonstrated that a slag, an industrial solid waste, can be used as a structural reinforcement. The mechanical properties(tensile strength and Elastic modulus) of slag reinforced composite(SRC) was investigated as functions of slag particle size (8~12 ${\mu}m$ and 12~16 ${\mu}m$) and volume fraction (0-40 vol.%). In order to investigate the interface and a degree of particle dispersion which have an effect on mechanical properties, optical microscopic images were taken. The results of tensile tests showed that the tensile strength decreased with an increase in slag volume fraction and particle size. The elastic modulus increased with an increase in slag volume fraction and particle size except for 30 vol.% SRC. The tensile strength decreased with an increase in slag particle size. The microscopic picture showed SRC has fine degree of particle dispersion at low slag volume fraction. SRC has a good interface at every volume fraction. However particle cluster was incorporated with an increase in slag volume fraction.

EVALUATION OF SHEAR BEHAVIOR OF LARGE GRANULAR MATERIALS WITH DIFFERENT PARTICLE SIZES BY TRIAXIAL TEST AND NUMERICAL SIMULATION

  • Kim, Bum-Joo;Sagong, Myung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.55-60
    • /
    • 2010
  • Rockfill zones in CFRD consist typically of large granular materials, usually the maximum particle size up to several meters, which makes laboratory testing to determine the mechanical properties of rockfill difficult. Commonly, the design strength of the rockfills is obtained by scaling down the original rockfill materials and performing laboratory strength tests for the reduced size materials. The objective of the present study is to investigate the effect of particle size on the shear behavior and the strength for granular materials. A series of large-scale triaxial tests was conducted on large granular materials with the maximum particle size varying from 20 to 50mm. The test results showed that overall shear behaviors were similar between the samples with different particle sizes while there were slight differences in the magnitudes of the peak shear stress between the samples. In addition, a simulation of the granular material with the max. particle size of 20mm was performed using DEM code, $PFC^{2D}$, and compared with the test results. The deviatoric stress versus strain behaviors of experimental and numerical tests were found to be matched well up to the peak stress state.

  • PDF

Evaluation of Alginate Microspheres Prepared by Emulsion and Spray Method for Oral Vaccine Delivery System (유화법과 분무법에 의해 제조된 경구백신용 알긴산 마이크로스피어의 평가)

  • Jiang, Ge;Jee, Ung-Kil;Maeng, Pil-Jae;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.241-256
    • /
    • 2001
  • Alginate microspheres, containing fluorescein isothiocyanate-bovine serum albumin (FITC-BSA) or green fluorescent protein (GFP) were prepared and used as a model drug to develop the oral vaccine delivery system. The alginate microspheres were coated with poly-L-lysine or chitosan. Two methods, w/o-emulsion and spray, were used to prepare alginate microspheres. To optimize preparation conditions, effects of several factors on the particle size and particle morphology of microsphere, and loading efficiency of model antigen were investigated. In both preparation methods, the particle size and the loading efficiency were enhanced when the concentration of sodium alginate increased. In the w/o-emulsion preparation method, as the concentration of Span 80 was increased from 0.5% to 2%, the particle size was decreased, but the loading efficiency was increased. The higher the emulsification speed was, the smaller the particle size and loading efficiency were. The concentration of calcium chloride did not show any effect on the particle size and loading efficiency. In the spray preparation method, the particle size was increased as the nozzle pressure $(from\;1\;kgf/m^2\;to\;3\;kgf/m^2)$ and spray rate was raised. Increasing calcium chloride concentration (<7%) decreased the particle size, in contrast to no effect of calcium chloride concentration on the w/o-emulsion preparation method. Alginate microspheres prepared by two methods were different in the particle size and loading efficiency, the particle size of microspheres prepared by the spray method was about $2-6\;{\mu}m$, larger than that prepared by the w/o emulsion method $(about\;2{\mu}m)$, and the loading efficiency was also higher with spray method. Furthermore, drying process for the microspheres prepared by the spray was simpler and easier, compared with the w/o emulsion preparation. Therefore, the spray method was chosen to prepare alginate microspheres for further experiments. Release pattern of FITC-BSA in alginate microspheres was evaluated in simulated intestinal fluid and PBS (phosphate buffered saline). Dissolution rate of FITC-BSA from alginate/chitosan microsphere was lower than that from alginate microsphere and alginate/poly-L-lysine microsphere. By confocal laser scanning microscope, it was revealed that alginate/FITC-poly-L-lysine microspheres were present in close apposition epithelium of the Peyer's patches of rabbits following inoculation into lumen of intestine, which proved that microspheres could be taken up by Peyer's patch. In conclusion, it is suggested that alginate microsphere prepared by spray method, showing a particle size of & $10\;{\mu}m$ and a high loading efficiency, can be used as a model drug for the development of oral vaccine delivery system.

  • PDF

Particle Size, Morphology and Color Characteristics of C.I. Pigment Red 57:1 : 1. Effect of Synthesis Conditions

  • Seo, Hee Sung;Lee, Hyun Kyung;Yoo, Eui Sang
    • Textile Coloration and Finishing
    • /
    • v.27 no.4
    • /
    • pp.229-244
    • /
    • 2015
  • The effects of synthesis conditions on characteristics of the calcium-azo complex pigment, C.I. Pigment Red 57:1, were studied. It was mainly considered that the industrially required synthesis conditions for lowering electrical conductivity of the pigment solution keeping pigment quality such as particle size and color characteristics. Three parameters were chosen as control factors during the synthesis. The first was the amount of hydrochloric acid added to transform sodium nitrite into nitrous acid. The second was the amount of calcium chloride added to insolubilize the synthesized azo dye. The final factor was pH control during the coupling reaction. The electrical conductivity and pigment aggregate particle size were dependent on the amount of hydrochloric acid and calcium chloride. Higher HCl concentration gave brighter yellowish-red color because of smaller particle aggregate size and narrower size distribution. Amount of charged ions in the synthesis process might affect the "lake" formation resulting different particle aggregate size and color shade.