• 제목/요약/키워드: particle removal efficiency

검색결과 348건 처리시간 0.035초

비이온 계면활성제를 이용한 복사고지의 중성탈묵 (Neutral Deinking of Photocopied Papers with Nonionic Surfactants)

  • 정영재;이학래
    • 펄프종이기술
    • /
    • 제33권2호
    • /
    • pp.58-67
    • /
    • 2001
  • MOW (Mixed Office Waste) mainly consisted of photocopied paper is being recycled to produce tissue or fine paper products. Toner particles that are fused and set on paper surface in photocopying process turns into large and plate-shaped particles after repulping which prevents them to be removed effectively in flotation deinking. The immediate purpose of this study is to find the effective deinking technology that increases the recycling potential of photocopied papers for manufacturing tissue and fine paper products. In this study the effects of pulping temperature and the type of hydrophobic groups of nonionic surfactants on the deinking efficiency of photocopied paper has been investigated. Particle size distribution of the toner particles after pulping and flotation, brightness, yield and ash removal were investigated. The size of toner particles after pulping increased as the pulping temperature was increased. When pulping at the low temperature finer toner particles were generated, however, greater amount of toner particles was found to attach to the fiber. When the pulping temperature was greater than Tg of the toner, the amount of coarse hairy particles increased. When nonionic surfactants with a double bond in hydrophobic groups were used, toner removal efficiency, brightness and ash removal were increased. As the addition level of surfactant was increased, yield decreased rather sharply without improving brightness.

  • PDF

이류체 노즐을 이용한 FPD 세정시스템 및 공정 개발 (Optimization of FPD Cleaning System and Processing by Using a Two-Phase Flow Nozzle)

  • 김민수;김향란;김현태;박진구
    • 한국재료학회지
    • /
    • 제24권8호
    • /
    • pp.429-433
    • /
    • 2014
  • As the fabrication technology used in FPDs(flat-panel displays) advances, the size of these panels is increasing and the pattern size is decreasing to the um range. Accordingly, a cleaning process during the FPD fabrication process is becoming more important to prevent yield reductions. The purpose of this study is to develop a FPD cleaning system and a cleaning process using a two-phase flow. The FPD cleaning system consists of two parts, one being a cleaning part which includes a two-phase flow nozzle, and the other being a drying part which includes an air-knife and a halogen lamp. To evaluate the particle removal efficiency by means of two-phase flow cleaning, silica particles $1.5{\mu}m$ in size were contaminated onto a six-inch silicon wafer and a four-inch glass wafer. We conducted cleaning processes under various conditions, i.e., DI water and nitrogen gas at different pressures, using a two-phase-flow nozzle with a gap distance between the nozzle and the substrate. The drying efficiency was also tested using the air-knife with a change in the gap distance between the air-knife and the substrate to remove the DI water which remained on the substrate after the two-phase-flow cleaning process. We obtained high efficiency in terms of particle removal as well as good drying efficiency through the optimized conditions of the two-phase-flow cleaning and air-knife processes.

고급알코올을 이용한 토너의 응집 및 스크리닝을 통한 제거 효과 (Agglomeration of Toner Particles with Fatty Alcohol and Their Removal by Screening)

  • 허용성;이학래
    • 펄프종이기술
    • /
    • 제36권2호
    • /
    • pp.24-32
    • /
    • 2004
  • Toner used in xerographic printing process is hydrophobic powder with low surface energy. The toner ink film fused on paper surface can be efficiently detached from a fiber surface during pulping, but it does not fragment again into fine toner particles. Ink agglomerates that result have too large particle size to be deinked by flotation. The purpose of this study is to enhance toner agglomeration using 1-octadecanol for improving the toner removal by screening. The effect of pH, pulping temperature, and 1-octadecanol on toner agglomeration and removal by screening was investigated using image analysis methods. Results showed that the size of toner agglomerates increased substantially when pulping was carried out at high temperature under acidic condition. When toner agglomerates showed spherical shape, the particle removal efficiency of screening was improved.

코로나 방전 시스템을 이용한 연소가스중의 NOx, $SO_2$제거 (Removal of NOx and $SO_2$ from Combustion Flue Gases by Corona Discharge Systems)

  • 박재윤
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.830-835
    • /
    • 1997
  • In this study an experimental investigation has been conducted to remove NOx and SO$_2$simultaneously from a combustion flue gases were consisted of NO-SO$_2$-$CO_2$-$N_2$-O$_2$([NO]o:200ppm and [SO$_2$]o:800ppm) and the injection gases used as radical source gases were NH$_3$-Ar-air and CH$_4$-Ar-air. NOx and SO$_2$removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as SO$_2$, NOx and NO$_2$gas detectors. and SEM images after sampling. The results showed that a significant Nucleating Particle Counter(CNPC) and SEM images after sampling. The results showed that a significant aerosol particle formation was observed during a simultaneous NOx and SO$_2$removal operation in corona radical shower systems. The diameter of aerosol particles was in the range of 0.18 to 3.6${\mu}{\textrm}{m}$ with a maximum fraction of particles at particles diameter of 1${\mu}{\textrm}{m}$. The NOx removal efficiency significantly increased with increasing applied voltage and NH$_3$molecule ratio. The SO$_2$removal efficiency was not significantly effected by applied voltage and slightly increased with increasing NH$_3$molecule ratio. It could be found that it is possible to use CH$_4$for NOx and SO$_2$removal by corona radical shower systems.

  • PDF

입상여과에서 입자물질의 부착 (Particle Attachment in Granular Media Filtration)

  • 김진근
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.666-672
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and pH control was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPD of the effluent did not keep moving from less negative to more negative during the later stages of filtration, and this result was thought to be caused by two reasons: ripening effects and the detachment of flocs.

3차원 수치모의를 통한 침사지에서의 부유사 밀도류 해석 (Three-dimensional numerical modeling of sediment-induced density currents in a sedimentation basin)

  • 안상도;김기호;박원철
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.383-394
    • /
    • 2013
  • A sedimentation basin is used to remove suspended sediments which can cause abrasive and erosive wear on hydraulic turbines of hydropower plants. This sediment erosion not only decreases efficiency of the turbine but also increases maintenance costs. In this study, the three-dimensional numerical simulations were carried out on the overseas hydropower project. The simulations of flow and suspended sediment concentration were obtained using FLOW-3D computational fluid dynamics code. The simulations provide removal efficiency of a sedimentation basin based on particle sizes. The influence of baffles on the flow field and the removal efficiency of suspended sediments in the sedimentation basin has been investigated. This paper also provides the numerical simulations for sediment-induced density currents that may occur in the sedimentation basin. The simulation results indicate that the formation of density currents decreases the removal efficiency. When a baffle is installed in the sedimentation basin, the baffle provides intensive settling zones resulting in increasing the sediments settling. Thus the enhanced removal efficiency can be achieved by installing the baffle inside the sedimentation basin.

T형의 waveguide를 이용한 Post CMP용 메가소닉 세정장치에 대한 연구 (Study of T Type Waveguide in Single Wafer Megasonic Cleaning for Post CMP)

  • 김태곤;이양래;임의수;강국진;김현세;박진구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.364-365
    • /
    • 2006
  • Transverse some wave was generated by T type waveguide for single wafer cleaning application T type megasonic waveguide was analyzed by acoustic pressure measurements and particle removal efficiency. Compared to conventional longitudinal waves, not like longitudinal waves, transverse waves showed changes of direction and phase which increased the cleaning efficiency.

  • PDF

혼합응집제에 의한 자연유기물질 제거에 미치는 영향 인자 (Influencing Factors on NOM Removal using Blended Coagulants)

  • 명복태;우달식;최종헌;문철훈;이윤진;조영태;조관형;남상호
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.96-103
    • /
    • 2001
  • This study was carried out to investigate the major factors for the removal of NOMs (Natural Organic Matters) by alum ferric chloride and blended coagulants that consisted of alum and ferric chloride. Investigated factors were pH, the dosage of coagulant, alkalinity, hardness and bloc strength. The particle size contained in the test water came from the Han River was also measured. DOC(Dissolved Organic Carbon) removal at pH 6 was two to three times higher than at pH 8.5. The blended coagulant showed 9 to 10 percent higher DOC removal efficiency and 2 to 4 percent higher turbidity under the same condition. Alkalinity consumption of alum, ferric chloride and blended coagulant was 81%, 90% and 86% of theoretical value, respectively. The limit concentration of alkalinity to avoid pin floe was 10 mg $CaCO_3/L$ when alum was used. Hardness had no apparent effect on coagulation. The residual turbidity and $UV_{254}$ showed a tendency of increasing with floc strength($sec^{-1}$) increase. The order of floe strength was the following; alum >blended coagulant > ferric chloride. The particle counter test showed 89 percent of the small particle size(SPS, $1~5{\;}{\mu}textrm{m}$) and 11 percent of the medium to large particle size(M.LPS, $5~125{\;}{\mu}textrm{m}$). At PH7.85, the particle removal efficiencies of SPS($1~5{\;}{\mu}textrm{m}$) and M.LPS($5~125{\;}{\mu}textrm{m}$) in the coagulation process were 81% and 95%, respectively.

  • PDF

웨이퍼 표면의 Si3N4 파티클 제거를 위한 초임계 이산화탄소 세정 (The Removal of Si3N4 Particles from the Wafer Surface Using Supercritical Carbon Dioxide Cleaning)

  • 김용훈;최해원;강기문;안톤커랴킨;임권택
    • 청정기술
    • /
    • 제24권3호
    • /
    • pp.157-165
    • /
    • 2018
  • 본 연구에서는 초임계 이산화탄소와 공용매 첨가물을 이용하여 실리콘 웨이퍼 표면의 $Si_3N_4$ 파티클을 제거하는 기술을 조사하였다. 우선, 몇 가지 계면활성제와 첨가제에 관한 초임계 이산화탄소 용해도 및 파티클 분산성 평가를 통하여 초임계 공정에 대한 적합성을 확인하였다. 다양한 변수를 조정하여 파티클 세정 실험을 진행하여 최적의 제거 조건을 확립하였다. 실험에 사용된 계면활성제는 파티클 제거 효과가 떨어졌으며, 실험 후 이차 오염물이 형성됨을 확인하였다. 반면 trimethyl phosphate는 IPA공용매와 미량의 HF와 혼합된 세정 첨가제로서 초임계 이산화탄소에 5 wt%로 포함한 유체로 온도 $50^{\circ}C$, 압력 2000 psi에서 $15mL\;min^{-1}$의 유속으로 4분 간 세정한 결과, 85%의 파티클 제거 효율을 나타내었다.

압축성 여재 여과를 이용한 하수의 고형물질 제거 타당성 연구 (Feasibility Study on Removal of Total Suspended Solid in Wastewater with Compressed Media Filter)

  • 김예슬;정찬일;오재일;윤여민
    • 대한환경공학회지
    • /
    • 제36권2호
    • /
    • pp.84-95
    • /
    • 2014
  • 최근 미국과 일본을 중심으로 높은 공극과 압축성이라는 장점을 지닌 압축성 섬유여재 여과에 대한 다양한 기술이 개발되면서 이를 이용한 집약적 하 폐수 처리에 대한 관심이 높아지고 있다. 이에 따라 본 연구에서는 다양한 유입수질의 하수에 대하여 압축성 섬유여재 여과의 적용성을 검토하고자 하며, 해당 유입수에 대한 최적의 운전조건을 도출하고자 한다. 이를 위하여 예비 실험으로서 추적자 시험을 진행하였으며, 이를 통하여 다양한 압축률 및 여과율에서의 여과 양상을 검토하였다. 그 결과 높은 압축률에서 높이에 따라 다른 공극률이 적용되어 이론적인 결과값과의 뚜렷한 차이를 관찰할 수 있었다. 하수처리장의 침사지 유출수를 대상으로 다양한 압축률 조건에서 압축성 섬유여재 여과의 TSS 제거 및 제거 입자크기분포를 살펴본 결과, 압축률 30%가 최적의 운전조건으로서 제거효율 70% 이상을 나타냈으며, 작은 크기의 입자 제거율 증대를 위해 최소 15% 이상의 압축률이 요구되었다. 또한 여과 유출수 농도의 주요 영향인자인 $10{\mu}m$ 이하 입자의 제거 효율을 증대시키기 위해서는 응집과 같은 추가 공정이 필요하다고 판단되었다. 모델링 결과를 통하여 압축률이 증가할수록 여과 초기에 입자 크기에 따른 TSS 제거효율이 두드러지게 나타남을 관찰하였고, 유입수의 입자크기분포에서 가장 큰 비율을 차지하는 $10{\mu}m$ 크기 입자를 대상으로 높이에 따른 모델링 결과 높이 150-300 mm 여재층이 해당 입자 크기에 대하여 가장 활발한 여과 작용을 나타내었다.