• 제목/요약/키워드: particle removal efficiency

검색결과 348건 처리시간 0.029초

Separation Performance of a Low-pressure Hydrocyclone for Suspended Solids in a Recirculating Aquaculture System

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • 제13권2호
    • /
    • pp.150-156
    • /
    • 2010
  • The separation performance of a low-pressure hydrocyclone (LPH) was evaluated for suspended-solids removal in a recirculating aquaculture system (RAS). The dimensions of the LPH were 335 mm cylinder diameter, 575 mm cylinder height, 60 mm overflow diameter, 50 mm underflow diameter, and $68^{\circ}$ cone angle. The inflow rate varied (400, 600, 800, and 1,000 mL $s^{-1}$) with 25%, 25%, 20%, and 10% of bypass ($R_f$), respectively. The maximum total separation efficiency (Et) and reduced separation efficiency (E't) for suspended solids from the effluent of the second settlement tank (before biofiltration) were 58.9% and 45.2%, respectively, at an inflow rate of 600 mL $s^{-1}$ and 25% of $R_f$. The maximum Et and E't for suspended solids from the water supply channel (after biofiltration) were 24.4% and 16%, respectively, at an inflow rate of 1,000 mL $s^{-1}$ and 10% of $R_f$. The maximum grade efficiency (Ei) was 51.6% for a 300 ${\mu}m$ particle size at an inflow rate of 600 mL $s^{-1}$ with 23% of $R_f$. The maximum reduced grade efficiency (E'i) was 37.6% for a 300 ${\mu}m$ particle size at an inflow rate of 1,000 mL $s^{-1}$ with 11% of $R_f$. The results indicate that the separation performance of the LPH for suspended solids removal was size selective and that maximum removal occurred at particle sizes ranging from 300 to 500 ${\mu}m$.

충진밀도와 여과속도가 섬유사 여과기의 처리 성능에 미치는 영향 (The Effect on Treatment Performance of Fiber Filter Under Various Packing-Density and Filtration Velocity)

  • 임정훈;김효관;이정준;문태섭;정민기;우혜진;김창원
    • 대한환경공학회지
    • /
    • 제28권2호
    • /
    • pp.216-222
    • /
    • 2006
  • 본 연구에서는 국내에서 개발되어진 섬유사 필터의 충진밀도와 여과속도가 처리 효율에 미치는 영향에 대한 연구결과를 나타내었다. 0.93 mm의 직경을 가진 폴리아마이드 섬유사가 충진된 직경 40 cm, 높이 2 m의 pilot-scale 규모의 반응기에서 수행되었다. 충진밀도가 섬유사 여과기의 처리효율에 미치는 영향을 살펴보기 위해 여과속도를 325 m/hr로 고정하고 충진밀도를 $70kg/m^3$에서 $100kg/m^3$의 범위에서 운전하였으며, 이와 반대로 여과 속도가 섬유사 여과기의 처리효율에 미치는 영향을 연구하기 위해서 충진밀도를 $70kg/m^3$으로 고정시킨 뒤 여과속도를 65 m/hr에서 400 m/hr의 범위로 운전하였다. 충진밀도가 증가할수록 여과 압력은 기하급수적으로 증가하였다. 탁도 및 SS 제거효율은 $80kg/m^3$까지는 30% 이내의 낮은 제거효율을 나타내었으며, $100kg/m^3$에서도 50% 이하의 낮은 제거효율을 나타내었다. 여과속도에 따른 섬유사 여과기의 여과압력은 여과 속도와 비례적으로 증가하였다. 여과속도가 낮을수록 탁도와 SS의 제거효율도 증가하였으며 65 m/hr에서 73%의 제거 효율을 나타내었다. 전체적으로, 섬유사 여과기를 이용한 입자상 물질의 제거 효율을 개선하기 위해서는 충진 밀도 보다 여과속도를 유입수 특성에 따라 적절히 조절하는 것이 효과적인 것으로 나타났다.

패각 폐기물을 이용한 $H_2S$ 제거에 관한 연구(I) -열중량분석기를 이용한 황화반응특성- (A Study on the $H_2S$ Removal with Utilization of Seashell Waste(I) -The Characteristics of Sulfided Reaction Using Thermal Gravimetric Analyzer-)

  • 김영식
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.45-49
    • /
    • 2003
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove H$_2$S. According to TGA results, temperature had influenced on H$_2$S removal efficiency. As desulfurization temperature increased, desulfurization efficiency increased. Also, maximum desulfurization efficiency was observed at 80$0^{\circ}C$. Desulfurization was related to calcination temperature. Considering temperature ranges of exhausted gas from hot gas gasification equipment were 400~80$0^{\circ}C$. Thus, desulfurization efficiency would be increased desulfurization temperature situation at highly. Experiments by TGA showed that particle size of sorbents had influenced on desulfurization capacity. Maximum desulfurization capacity was observed at 0.631 mm for oyster and clam. Rest of sorbents showed similar capacity within 0.171~0.335 mm particle size range. So, particle size would be considered. When would be used waste shells as IGCC sorbents. According to the results about desulfurization capacity by TGA, oyster had the best desulfurization capacity among limestone and waste shell. We would be identify to substituted oyster for existing sorbents

입구 습도 변화에 따른 관성 충돌 방식의 액적 분리장치의 수분제거효율 변화 (Removal Efficiency of Water Contents using Inertial Impaction Separator with Change in Relative Humidity)

  • 송동근;이신영;홍원석;신완호;김규진;김한석
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.247-252
    • /
    • 2013
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For design and incorporation of inertial pre-treatment separator, characteristics of removal of water contents with various operation conditions are needed. In this study, removal efficiency of water droplets at various flowrates (5-14 SCMM) and relative humidity (R.H.) conditions (40%, and 90%) has been investigated. At low R.H. condition, the removal characteristic is similar to the removal of solid particles. But, droplet growth resulting from the condensation of water vapor at high R.H. condition, is significant and it made increase in removal efficiency of droplet phase of water contents. For rapid removal of water contents, an effective method to enhancing condensation growth of water droplets is highly needed.

인공습지 기본형상에서 전산유체역학을 이용한 사류구간 및 입자제거율 평가 (Evaluation of hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland using computational fluid dynamics)

  • 최영균;박민철
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.495-502
    • /
    • 2013
  • Hydraulic dead-zone and particle removal efficiency in the base frame of a constructed wetland was evaluated with computational fluid dynamics (CFD). The fraction of hydraulic dead-zone was estimated to be 1.2-2.1 % (v/v) and it was attributed to the artificial islands developed in the constructed wetland. Solids deposition rate could be increased with higher hydraulic retention time (HRT, ranged from 2.2 to 4.2 hr) of the wetland and larger particle size (ranged from 10 to $50{\mu}m$) in the influent. Experimental results showed that the volume concentration of the particles smaller than $10{\mu}m$ in diameter was varied from $1.99{\times}10^3{\mu}m^3/ml$ (HRT 12.8 hr) to $3.92{\times}10^3{\mu}m^3/ml$(HRT 2.2 hr) in the influent of the constructed wetland. With the effluent volume concentration data, removal efficiency of those particles was calculated to be 71.2 and 24.7 % when the HRT was 12.8 and 2.2 hr, respectively. Similar trend with the HRT variation could be identified with CFD analysis.

실내 공기정화 시스템에 의한 실내 오염입자의 제거특성에 관한 실험적 연구 (An Experimental Study on the Removal Characteristics of Indoor Air Pollutants using an Air Cleaning System)

  • 김성찬;이창건;안영철;이재근;강태욱;이감규;구정환
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.733-737
    • /
    • 2003
  • The purpose of this study is to analyze the particle removal characteristics of a commercial air cleaner based on the electrostatic precipitator. The air cleaner consists of a positive corona precharger to precharge particles and a collector to remove the charged particles. The test for particle removal efficiency is conducted with tobacco smoke particles of 1.27${\mu}{\textrm}{m}$ in mass median diameter. The result of one-pass filtration test shows that the filtration efficiency is more than 90% for the particles larger than 2.5 Um, while the efficiency for the particles of 0.5~1.0${\mu}{\textrm}{m}$ in case of 4.18 CMM is 70%. For the test room of 5,800${\times}$3,400${\times}$2,600㎣, the concentration of tobacco smoke particles decreases up to 30% of initial values within 30 minutes due to natural reduction and up to 90% of initial values within 30 minutes with the air cleaner operation.

Experimental Study on the Enhancement of Particle Removal Efficiency in Spray Tower Scrubber Using Electrospray

  • Kim, Hyeok-Gyu;Kim, Hong-Jik;Lee, Myong-Hwa;Kim, Jong-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권2호
    • /
    • pp.89-95
    • /
    • 2014
  • There have been a lot of efforts to keep permissible emission standards and to reduce the amount of emitted air pollutants. There are several air pollution control equipments, however, wet scrubber is used to remove particulate matters and gaseous pollutants simultaneously, even if it has low collection efficiency in the particle size less than $5.0{\mu}m$. To overcome this problem, we introduced a spray tower scrubber with an electrospray system which a high voltage was indirectly applied. We found that collection efficiency of fine particles in the electrospray system was improved by increasing electrical field strength and the ratio of liquid-gas flow rate (from 41% to 84% for $0.3{\mu}m$ particles). In addition, a number of small droplets generated from an electrospray system led high collection efficiency, resulting from electrostatic attraction between droplets and particles and higher collision frequency. Therefore, we can conclude that the introduction of an electrospray system is quite effective to increase the particle removal efficiency of a spray tower scrubber.

2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구 (Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets)

  • 김수민;김학준;김명준;한방우;우창규;김용진
    • 한국입자에어로졸학회지
    • /
    • 제13권3호
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.

유연성 섬유사 여과기를 이용한 순환여과식 양식장의 부유고형물 제거 (Removal of Suspended Solids Using a Flexible Fiber Filter in a Recirculating Aquaculture System)

  • 최광수
    • 한국수산과학회지
    • /
    • 제40권2호
    • /
    • pp.73-78
    • /
    • 2007
  • The suitability of a flexible fiber filter for removing suspended solid (SS) in a recirculating aquaculture system was evaluated. This study focused on variation in the performance with a change in filtering time, influent water quality, and filtering mode duration. The particle distribution diagram of the filter effluent showed that the number of particles bigger than $5-8{\mu}m$ decreased dramatically, and the removal efficiency exceeded 80%. Although the removal efficiencies of SS and chemical oxygen demand (COD) were dependent on the quality of the influent, the SS and COD concentrations of the effluent were not affected by the influent concentrations. This was despite the deterioration if water quality after feeding in the rearing tank. The performance of the filter was not affected by the filtering mode duration, feeding conditions, or filtering time. The SS concentration and turbidity of the recirculating-type rearing tank were 30% and 50% lower, respectively, than of the a non-recirculating-type rearing tank under the same operating conditions. The flexible fiber filter was applicable to a recirculating aquaculture system that uses plenty of seawater, based on its low filtering resistance $(2kg_f/cm^2)$, high flux $(330m^3/m^2/hr)$, and high fine particle removal efficiency (80%, $5-8{\mu}m$).

패각 폐기물을 이용한 $H_2S$ 제거에 관한 연구(II) -고정층 반응기를 이용한 황화반응특성 (A Study on the H??S Removal with Utilization of Seashell Waste(II) - The Characteristics of Sulfided Reaction Using Fixed Bed Reactor-)

  • 김영식
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.86-90
    • /
    • 2003
  • In this study, lots of methods have been studing to utilize energy and decrease contaminated effluents. There has been great progress on IGCC (Integrated gasification combined cycle) to reduce thermal energy losses. The following results have been conducted from desulfurization experiments using waste shell to remove H$_2$S. Fixed bed desulfurization experiments, to obtain basic data for scale-up was indicated. Oyster was the best among the various sorbents, like the results of TGA. Especially, H$_2$S removal efficiency of uncalcined oyster was the highest. When use oyster as desulfurization sorbents, calcination process was not needed. Thus, high desulfurization efficiency would be expected. Fixed bed reactor experiments were indicated particle size of sorbents. These had influenced on desulfurization capacity. As smaller particle size was found better desulfurization capacity. Large capacity difference was found between 0.613 mm and 0.335 mm. But, differences between 0.335 mm and 0.241 mm was relatively small. As bed temperature increased, H$_2$S removal capacity increased. Therefore, both particle size and bed temperature should be considered to remove H$_2$S by sorbents.