• Title/Summary/Keyword: particle injection

Search Result 443, Processing Time 0.029 seconds

Immobilization and Recycling of Arsenic-Contaminated Fine Soil Cake Produced after Soil Washing Process (토양세척 후 발생하는 비소오염 탈수미세토의 불용화 및 재활용 평가)

  • Oh, Minah;Moon, SoYoung;Hyun, Min;Chae, HeeHoon;Lee, Jai-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.9-16
    • /
    • 2012
  • Standardized remediation process for the soil contaminated with arsenic is insufficient due to characteristics of its anion-mobility and speciation changed by Eh-pH of soil. One of the well-known efficient remediation processes is the modified soil washing that particle separation process by only water. However, it is required that the treatment plan for the fine soil what was discharged after modified soil washing. Therefore, this research suggests the treatment plan that the recycling method using arsenic immobilization by FeS-$H_2O_2$. The batch experiments results for the arsenic immobilization showed that the water content was at least 50%, the injection of FeS and $H_2O_2$ (assay-35%) were 8% (w/watdrybase) and 0.2 mL/10 g of fine soil respectively. Arsenic concentration with KSLT was decreased about 95.4%. The results indicated that the mixing of FeS-$H_2O_2$ was highly efficient on the immobilization of As-contaminated soil. The mixing ratio as 13% of bentonite with 3% of cement (at based on 100% of immobilized fine soil) was satisfied with standard of liner for landfill construction.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Pulse Corona induced Plasma Chemical Processing (PPCP에 의한 연소가스 중 NOx, SOx 동시제거 특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Jung, Jang-Gun;Kim, Jung-Dal
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.211-216
    • /
    • 2000
  • In this paper, experimental investigations were carried out to remove NOx, SOx simultaneously from a simulated combustion flue gas [$NO(0.02%)-SO_2(0.08%)-CO_2-Air-N_2$] by using a pulse corona induced plasma chemical processing. Discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was $2.5{\ell}/min$ for bubbling aqueous NaOH solution. Ammonia gas(l4.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio(MR) was determined based on [$NH_3$] and [$NO+SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration. but SOx removal rate was not significantly affected by initial concentration. The NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF

Characteristics of Continuous Preparation of ZnO Powder in a Micro Drop/bubble Fluidized React (마이크로 액적/기포 유동반응기에서 ZnO 입자의 연속제조 특성)

  • Lee, Seung Ho;Yang, Si Woo;Lim, Dae Ho;Yoo, Dong Jun;Lee, Chan Ki;Kang, Gyung Min;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.597-602
    • /
    • 2015
  • Characteristics of continuous preparation of ZnO powder were investigated in a micro drop/bubble fluidized reactor of which diameter and height were 0.03 m and 1.5 m, respectively. The flow rate of carrier gas for transportation of precursors to the reactor was 6.0 L/min and the concentration of Zn ion in the precursor solutions was 0.4 mol/L, respectively. Effects of reaction temperature (973 K~1,273 K) and flow rate of micro bubbles (0~0.4 L/min) on the pore characteristics of prepared ZnO powder were examined. The optimum reaction temperature for the maximum porosity in the ZnO powder was 1,073 K within this experimental condition. The mean size of ZnO powder prepared continuously in the reactor decreased but the surface of the powder became smooth, with increasing reaction temperature. The injection of micro bubbles into the reactor could enhance the formation of pores in the powder effectively, and thus the mean BET surface area could be increased by up to 58%. The mean size of prepared ZnO powder was in the range of $1.25{\sim}1.75{\mu}m$ depending on the reaction temperature.

Determination of Betaine in Fructus Lycii Using Hydrophilic Interaction Liquid Chromatography with Evaporative Light Scattering Detection

  • Shin, Hyun-Du;Suh, Joon-Hyuk;Kim, Jung-Hyun;Lee, Hye-Yeon;Eom, Han-Young;Kim, Un-Yong;Yang, Dong-Hyug;Han, Sang-Beom;Youm, Jeong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.553-558
    • /
    • 2012
  • A simple new method was developed for the determination of betaine in Fructus Lycii using hydrophilic interaction liquid chromatography with evaporative light scattering detection (HILIC-ELSD). Good chromatographic separation and reasonable betaine retention was achieved on a Kinetex HILIC column ($2.1{\times}100mm$, $2.6{\mu}m$) packed with fused-core particle. The mobile phase consisted of (A) acetonitrile and (B) 10 mM ammonium formate (pH 3.0)/acetonitrile (90/10, v/v). It was used with gradient elution at a flow rate of 0.7 mL/min. The column temperature was set at $27.5^{\circ}C$ and the injection volume was $10{\mu}L$. The ELSD drift tube temperature was $50^{\circ}C$ and the nebulizing gas (nitrogen) pressure was 3.0 bar. Stachydrine, a zwitterionic compound, was used as an internal standard. Calibration curve over $10-250{\mu}g/mL$ showed good linearity ($R^2$ > 0.9992) and betaine in the 70% methanol extract of Fructus Lycii was well separated from other peaks. Intraand inter-day precision ranged from 1.1 to 3.0% and from 2.4 to 5.3%, respectively, while intra- and inter-day accuracy ranged from 100.0 to 107.0% and from 94.3 to 103.9%, respectively. The limit of quantification (LOQ) was $10{\mu}g/mL$ and the recoveries were in the range of 98.2-102.7%. The developed HILIC-ELSD method was successfully applied to quantitatively determine the amount of betaine in fourteen Fructus Lycii samples from different locations, demonstrating that this method is simple, rapid, and suitable for the quality control of Fructus Lycii.

Eco-Friendly Light Emitting Diodes Based on Graphene Quantum Dots and III-V Colloidal Quantum Dots

  • Lee, Chang-Lyoul
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.65-65
    • /
    • 2015
  • In this talk, I will introduce two topics. The first topic is the polymer light emitting diodes (PLEDs) using graphene oxide quantum dots as emissive center. More specifically, the energy transfer mechanism as well as the origin of white electroluminescence in the PLED were investigated. The second topic is the facile synthesis of eco-friendly III-V colloidal quantum dots and their application to light emitting diodes. Polymer (organic) light emitting diodes (PLEDs) using quantum dots (QDs) as emissive materials have received much attention as promising components for next-generation displays. Despite their outstanding properties, toxic and hazardous nature of QDs is a serious impediment to their use in future eco-friendly opto-electronic device applications. Owing to the desires to develop new types of nanomaterial without health and environmental effects but with strong opto-electrical properties similar to QDs, graphene quantum dots (GQDs) have attracted great interest as promising luminophores. However, the origin of electroluminescence (EL) from GQDs incorporated PLEDs is unclear. Herein, we synthesized graphene oxide quantum dots (GOQDs) using a modified hydrothermal deoxidization method and characterized the PLED performance using GOQDs blended poly(N-vinyl carbazole) (PVK) as emissive layer. Simple device structure was used to reveal the origin of EL by excluding the contribution of and contamination from other layers. The energy transfer and interaction between the PVK host and GOQDs guest were investigated using steady-state PL, time-correlated single photon counting (TCSPC) and density functional theory (DFT) calculations. Experiments revealed that white EL emission from the PLED originated from the hybridized GOQD-PVK complex emission with the contributions from the individual GOQDs and PVK emissions. (Sci Rep., 5, 11032, 2015). New III-V colloidal quantum dots (CQDs) were synthesized using the hot-injection method and the QD-light emitting diodes (QLEDs) using these CQDs as emissive layer were demonstrated for the first time. The band gaps of the III-V CQDs were varied by varying the metal fraction and by particle size control. The X-ray absorption fine structure (XAFS) results show that the crystal states of the III-V CQDs consist of multi-phase states; multi-peak photoluminescence (PL) resulted from these multi-phase states. Inverted structured QLED shows green EL emission and a maximum luminance of ~45 cd/m2. This result shows that III-V CQDs can be a good substitute for conventional cadmium-containing CQDs in various opto-electronic applications, e.g., eco-friendly displays. (Un-published results).

  • PDF

Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy (림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

A Study on the Cold Startability and Emission Characteristics of LPG Vehicle According to Test Temperature (시험온도에 따른 LPG 차량의 저온 시동성 및 배출가스 배출특성 연구)

  • Lee, Min-Ho;Kim, Sung-Woo;Kim, Ki-Ho;Ha, Jong-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.6
    • /
    • pp.7-13
    • /
    • 2014
  • As the interest on the air pollution is gradually rising up at home and abroad, automotive and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward various main issues : whether PM emissions should be regulated for diesel and gasoline vehicles and whether gasoline and LPG powered vehicles can be further neglected from PM emission inventories. Finally, the greenhouse gas ($CO_2$, $CH_4$, $N_2O$) regulation has been discussed including automotive emission regulation. The greenhouse gas and emissions (PM) particle of automotive had many problem that cause of ambient pollution, health effects. This paper discussed the influence of LPG fuel on automotive cold startability and exhaust emissions gas. Also, this paper assessed emission characteristics due to the test temperature. These test temperature were performed by dividing the temperature of the test mode and the lowest local temperature in winter. Through this study, the correlation of cold startability, exhaust emission and greenhouse gas emission was analyzed.

Development of 80 kW RF Thermal Plasma Torch System for Mass Production and Research of Si Nano-Powder Manufacturing Process (양산용 80 kW급 RF Plasma Torch System 개발 및 Si 나노분말 제조 공정 연구)

  • Song, Seok-Kyun;Son, Byungkoo;Kim, Byunghoon;Lee, Moonwon;Sin, Myungsun;Choi, Sunyong;Lee, Kyu-Hang;Kim, Seong-In
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.66-78
    • /
    • 2013
  • In order to develop of 80 kW RF plasma torch system, we achieved three-dimensional simulations for the extraction of more information as temperature in torch and fluid behavior analysis, etc. The position of powder injection tube, the plasma discharge characteristics with various input current and various length of ceramic tube, and the plasma temperature characteristics with process gas flow rate such those was simulated. RF thermal plasma torch designed by simulation was manufactured that was measured to the maximum of 89.3 kW power. The mass production using developed 80 kW RF thermal plasma torch system were investigated by characteristics manufactured of Si nano powder. The mass-production level of Si nano-powder was average of 539 g/hr and high yield rate of 71.6%, respectively. The particle size distribution $D_{99}/D_{50}$ of manufacturing nano-powder was investigated to 1.98 as a good uniform.

Correlation Analysis of Signal to Noise Ratio (SNR) and Suspended Sediment Concentration (SSC) in Laboratory Conditions (실험수로에서 신호대잡음비와 부유사농도의 상관관계 분석)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.775-786
    • /
    • 2017
  • Monitoring sediment flux is crucial especially for maintaining river systems to understand morphological behaviors. Recently, hydroacoustic backscatter (or SNR) as a surrogate to empirically estimate suspended sediment concentration has been increasingly highlighted for more efficient acquisition of sediment dataset, which is difficult throughout direct sediment sampling. However, relevant contemporary researches have focused on wide range solution applicable for large natural rivers where H-ADCPs with relatively low acoustic frequency have been widely utilized to seamlessly measure streamflow discharge. In this regard, this study aimed at investigating hydroacoustical characteristics based on a very recently released H-ADCP (SonTek SL-3000) with high acoustic frequency of 3 MHz in order to capitalize its capacity to be applied for suspended sediment monitoring in laboratory conditions. SL-3000 was tested in a laboratory flume to collect SNR in conjunction with LISST-100X for actual sediment concentration and particle distribution in both sand and silt sediment injection in various amount. Conventional algorithms to correct signal attenuations for water and sediment were carefully tested to validate whether they can be applied for SL-3000. As result of analyzing the SNR-SSC correlation trand, through further study in the future, it is confirmed that SSC can be observed indirectly by using the SNR.