• 제목/요약/키워드: particle flow rate

검색결과 642건 처리시간 0.029초

인천광역시에서 유통되는 계란의 플루오로퀴놀론계 항균물질 잔류 실태 조사 (A study on the residues of fluoroquinolones in hen's eggs consumed in Incheon Metropolitan city)

  • 박은정;임지흔;이성모;임정수;오대규
    • 한국동물위생학회지
    • /
    • 제31권3호
    • /
    • pp.385-395
    • /
    • 2008
  • This study was carried out to investigate the residue level of fluoroquinolones in hen's general eggs and specific eggs by microbiological assay method and high performance liquid chromatography (HPLC) method. HPLC separation was carried out by reversed phase chromatography on a Symmetry $C_{18}$ (250${\times}$4.6 mm, $5{\mu}m$ particle size) with a phase composed of distilled water (containing 0.4% triethylamine and phosphoric acid) : Methanol (780 : 220, v/v), pumped isocratically at a flow rate of 1.0ml/min. A fluorescence detector was utilized with an excitation wavelength of 278nm and an emission wavelength of 456nm. The calibration curves were linear $({\gamma}^2{\geq}0.999)$ over a concentration range of $0.025{\sim}0.4{\mu}g/ml$. Average recoveries of the five fluoroquinolones in whole eggs at fortified levels of $0.05{\sim}0.2{\mu}g/g$ were ranged mean $78.1{\sim}91.7%$ and low coefficient of variation was less than 10% for all analysed samples. The limits of detection and limits of quantification for whole eggs were $1.2{\sim}6.0ng/g$ and $2.3{\sim}9.1ng/g$, respectively. Only one hen's general eggfrom chicken farm in Incheon was detected with the residual fluoroquinolones (Microbiological assay method; 1 of 47 general eggs) ; the range of residual concentration enrofloxacin was 0.12ppm. Those in food stores were detected with the residual fluoroquinolones (Microbiological assay method; 4 of 88 general eggs) ; the ranges of residual concentration enrofloxacin were $0.15{\sim}2.2 ppm$, ciprofloxacin $0.01{\sim}0.06ppm$, and hen's specific eggs (40) in food stores were not detected. For the microbiological assay method of fluoroquinolones in hen's eggs, as the results of comparative analysis, the disc diffusion method with E coli may be a little highly detected for the residual fluoroquinolones.

기포 유동층 반응기를 이용한 하수슬러지 및 우드펠렛 혼소에 관한 연소 특성 분석 및 비교 (Experimental Study of Co-firing and Emission Characteristics Fueled by Sewage Sludge and Wood Pellet in Bubbling Fluidized Bed)

  • 이영재;김종민;김동희;이용운
    • 청정기술
    • /
    • 제23권1호
    • /
    • pp.80-89
    • /
    • 2017
  • 하수슬러지 고형연료 및 우드펠렛의 전소 및 혼소 실험을 위해 내경 0.1 m, 높이가 1.2 m인 기포 유동층 반응기를 적용하였으며, 장치는 유동층 반응기, 연료 공급장치, 사이클론, 냉각기, 그리고 가스분석기로 구성되었다. 층 물질의 평균입자크기는 $460{\mu}m$이며, 최소 유동화 속도는 $0.21ms^{-1}$이다. 실험에 사용된 연료는 국내산 하수슬러지 고형연료 및 캐나다산 우드펠렛을 적용하였으며, 우드펠렛 기준 혼합율 20, 50, 80%로 고위발열량을 기준으로 산정하였다. 실험 고정변수는 당량비 1.65, 산화제 $100Lmin^{-1}$, 반응기 온도 $800^{\circ}C$, 유동화수 4로 설정하였다. TGA 분석 결과, 하수슬러지의 고형 연료의 연소성이 우드펠렛이 비해 상대적으로 좋지 않았다. 연소시 반응기 온도는 $800{\sim}900^{\circ}C$ 사이로 유지되었으며, 유동층 반응기에서 하수 슬러지 고형연료의 낮은 연소성으로 인해 CO가 상대적으로 높게 측정되었다. 뿐만 아니라 $NO_X$$SO_X$는 하수슬러지 고형연료 내의 질소함량으로 인해 우드펠렛에 비해 높게 측정되었으며, 혼소율이 증가될수록 CO, $NO_X$, 그리고 $SO_X$의 배출이 감소하였다. 혼소에 따른 회분의 거동 및 퇴적 경향에서 모든 조건에 대해 슬래깅/파일링의 가능성이 높은 것으로 분석되었다.

Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection

  • Suh, Joon-Hyuk;Yang, Dong-Hyug;Lee, Byung-Kyu;Eom, Han-Young;Kim, Un-Yong;Kim, Jung-Hyun;Lee, Hye-Yeon;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2648-2656
    • /
    • 2011
  • A simple HPLC-DAD method was developed and validated to determine B group vitamin content (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine and folic acid) in supplemented food samples, i.e., infant formula, cereal, low-calorie food, a multi-vitamin pill and a vitamin drink. In this study, the most significant advantages were simultaneous determination of the six B group vitamins in various food matrices and a small number of sample treatment steps that required only an organic solvent, acetonitrile. Moreover, this method prevents reduction of column durability, because the mobile phase does not contain ion-pairing reagents. Analytes were separated on a Develosil RPAQUEOUS $C_{30}$ (4.6 mm ${\times}$ 250 mm, 5 ${\mu}M$ particle size) column with a gradient elution of acetonitrile and 20 mM phosphate buffer (pH 3.0) at a flow rate between 0.8 and 1.0 mL/min. Detection was performed at 275 nm, except for that of pantothenic acid (205 nm). The calibration curves for all six vitamins showed good linearity with correlation coefficients ($r^2$) higher than 0.995. The developed method was validated with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), recovery and stability. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% at all concentrations. The recovery was carried out according to the standard addition procedure, with yields ranging from 89.8 to 104.4%. This method was successfully applied to the determination of vitamin B groups in supplemented food products.

해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성 (Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems)

  • 김부기;한원희;조대환;최민선
    • 해양환경안전학회지
    • /
    • 제11권2호
    • /
    • pp.109-115
    • /
    • 2005
  • 하이드로사이클론은 다양한 산업 방면의 고$\cdot$액 분리를 위해 널리 사용되어왔다. 왜냐하면 하이드로사이클론의 적당한 응용으로 폭넓은 범위의 입자에 적용이 가능하기 때문이다. 불순물을 함유한 해수가 펌프나 열교환기로 흘러가면 그것은 해수 냉각시스템의 효율을 저하시키는 원인이 된다. 본 연구에서는 하이드로사이클론을 이용한 해수 냉각시스템에서 불순물을 분리하는 몇가지 방법을 제시했다. 설계의 영향을 미치는 인자로서 고체농도, 사이클론 입구압력, 하부배출구의 직경과 유량에 따른 하이드로사이클론의 분리효율에 대해 연구를 하였다. 이 연구의 결과는 다음과 같다. 1) 고형물질의 농도가 감소할수록 고$\cdot$액 분리의 효율이 증가하였다. 2) 사이클론 입구압력이 증가함에 따라 분리효율이 증가하였다. 결과적으로 이 연구에서는 하이드로사이클론을 기계류 냉각시스템의 전처리장치로 사용한다면 엔진시스템에서 예상치 못했던 사고를 방지할 수 있을 것이다.

  • PDF

해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성 (Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems)

  • 김부기;한원희;조대환;최민선
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 추계학술발표회
    • /
    • pp.109-115
    • /
    • 2004
  • 하이드로사이클론은 다양한 산업 방면의 고$\cdot$액 분리를 위해 널리 사용되어왔다 왜냐하면 하이드로사이클론의 적당한 응용으로 폭넓은 범위의 입자에 적용이 가능하기 때문이다. 불순물을 함유한 해수가 펌프나 열교환기로 흘러가면 그것은 해수 냉각시스템의 효율을 저하시키는 원인이 된다. 본 연구에서는 하이드로사이클론을 이용한 해수 냉각시스템에서 불순물을 분리하는 몇가지 방법을 제시했다. 설계의 영향을 미치는 인자로서 고체농도, 사이클론 입구압력, 하부배출구의 직경과 유량에 따른 하이드로사이클론의 분리효율에 대해 연구를 하였다 이 연구의 결과는 다음과 같다. 1) 고형물질의 농도가 감소할수록 고$\cdot$액 분리의 효율이 증가하였다. 2)사이클론 입구압력이 증가함에 따라 분리효율이 증가하였다. 결과적으로 이 연구에서는 하이드로사이클론을 기계류 냉각시스템의 전처리장치로 사용한다면 엔진시스템에서 예상치 못했던 사고를 방지할 수 있을 것이다.

  • PDF

만성폐쇄성폐질환 및 미세먼지 유발 폐손상 동물모델에서 과루행련환의 효과 (Effects of Gwaruhaengryeon-hwan on COPD and Particulate Matter Induced Lung Injury on a Mouse Model)

  • 이철화;양원경;유이란;김승형;박양춘
    • 대한한방내과학회지
    • /
    • 제38권3호
    • /
    • pp.353-366
    • /
    • 2017
  • Objective: This study aimed to use a mouse model to evaluate the effects of Gwaruhaengryeon-hwan (GHH) on chronic obstructive pulmonary disease (COPD) and particulate matter induced lung injury. Materials and Methods: The study was carried out in two ways (in vitro, in vivo). In vitro RAW 264.7 cells (mouse macrophage) were used and analyzed by flow cytometry, ELISA. In vivo lipopolysaccharide (LPS) and cigarette smoke solution (CSS), or coal, fly ash, diesel exhaust particle (CFD) challenged mice were used and its BALF was analyzed by ELISA, lung tissue by real-time PCR. Results: In vitro, GHH maintained an 80-100% rate of viability. So cytotoxicity was not shown. In the ELISA analysis with RAW 264.7 cells, GHH significantly decreased NO over $30{\mu}g/ml$. In the ELISA analysis, GHH significantly decreased $TNF-{\alpha}$, IL-6 over $300{\mu}g/ml$. In the COPD model, the GHH 200 mg/kg dosage group, the application of GHH significantly decreased the increasing of neutrophils, $TNF-{\alpha}$, IL-17A, MIP2, CXCL-1 in BALF, $TNF-{\alpha}$, $IL-1{\beta}$ mRNA expression in lung tissue and histological lung injury. In the CFD induced lung injury model, the GHH 200 mg/kg dosage group, the application of GHH significantly decreased the increase of neutrophils, $TNF-{\alpha}$, IL-17A, MIP2, CXCL-1 in BALF, MUC5AC, $TGF-{\beta}$ mRNA expression in lung tissue and histological lung injury. Conclusion: This study suggests the usability of GHH for COPD patients by controlling lung tissue injury.

반도체 습식 세정 공정 중 상온의 초순수와 염기성 수용액 내에서 오존의 용해도 최적화 (The Optimization of Ozone Solubility and Half Life Time in Ultra Pure Water and Alkaline Solution on Semiconductor Wet Cleaning Process)

  • 이상호;이승호;김규채;권태영;박진구;배소익;이건호;김인정
    • 반도체디스플레이기술학회지
    • /
    • 제4권4호
    • /
    • pp.19-26
    • /
    • 2005
  • The process optimization of ozone concentration and half life time was investigated in ultra pure water and alkaline solutions for the wet cleaning of silicon wafer surface at room temperature. In the ultra pure water,. the maximum concentration (35 ppm) of ozone was measured at oxygen flow rate of 3 liters/min and ozone generator power over 60%. The half life time of ozone increased at lower power of ozone generator. Additive gases such as $N_2$ and $CO_2$ were added to increase the concentration and half life time of ozone. Although the maximum ozone concentration was higher with the addition of $N_2$ gas, a longer half life time was observed with the addition of $CO_2$. When $NH_4OH$ of 0.05 or 0.10 vol% was added in DI water, the pH of the solution was around 10. The addition of ozone resulted in the half life time less than 1 min. In order to maintain high pH and ozone concentration, ozone was continuously supplied in 0.05 vol% ammonia solutions. 3 ppm of ozone was dissolved in ammonia solutions. The static contact angle of silicon wafer surface became hydrophilic. The particle removal was possible alkaline ozone solutions. The organic contamination can be removed by ozonated ultra pure water and then alkaline solution containing ozone can remove the particles on silicon surface at room temperature.

  • PDF

역상 고성능 액체 크로마토 그래피에 의한 Pd(II) - isonitrosoethylacetoacetate imine 유도체 킬레이트의 용리거동에 관한 연구 (A Study on the Elution Behavior of Pd-Isonitroso ethylacetoacetate imine Chelates by Reversed-phase High Performance Liquid Chromatography)

  • 김현
    • 대한화장품학회지
    • /
    • 제19권1호
    • /
    • pp.20-30
    • /
    • 1993
  • 본 연구는 역상 HPLC를 이용하여 Pb(IEAA-NR)2 (R=H, CH3, C3H7, C6H5, C4H9) 킬레이트를 동시 분리하기 위한 최적 분리 조건을 조사하고 이들의 용리거동에 관련된 인자들과의 관계를 검토하였는데 그 결과는 다음과 같다. 1. 각 Pb(IEAA-NR)2 킬레이트의 분리에 대한 기기의 최적 조건을 실험적으로 측정한 결과는 다음과 같다. 분리관 : Micropak MCH-5 (4.0 mm I.D. $\times$ 15 cm L, Particle size 5 $\mu\textrm{m}$) 용리액 : MeOH / H20 (73/27) 흐름속도 : 0.7 ${\mu}\ell$/min. 시료주입량 : 4 ${\mu}\ell$ 검출기 : UV 검출기 (254 nm) 2. 용리액의 흐름속도는 0.7${\mu}\ell$/min. 일때 적당한 분리 시간과 좋은 분리도를 나타내었다. 3. 시료 용매가 킬레이트의 머무름 시간에는 큰 영향을 주지 않았으며 금속 킬레이트간의 겸침 현상이 줄어들고 봉우리 면적이 큰 CH3CN을 사용하였다. 4. 용리액의 조성은 MeOH/H2O 의 비가 73/27 으로써 대개의 경우에 lig k' 값이 0$\leq$log k' $\leq$1을 잘 만족하지 않았으며 전체적으로 적당한 분리시간과 좋은 분리도를 나타내었다. 5. Pb(IEAA-NR)2 킬레이트의 log k' 값을 이성분 용매계에서 물의 부피 분율에 대하여 plot한 결과 이들이 직선적인 관계를 가지는 것으로 보아 Pb(IEAA-NR)2 의 머무름은 소수성 효과(Hydrophobic effect)에 크게 기인 한다는 것을 알 수 있었다.

  • PDF

리모트 수소 플라즈마를 이용한 Si 표면 위의 Fe 불순물 제거 (Removal of Fe Impurities on Silicon Surfaces using Remote Hydrogen Plasma)

  • 이종무;박웅;전부용;전형탁;안태항;백종태;신광수;이도형
    • 한국재료학회지
    • /
    • 제8권8호
    • /
    • pp.751-756
    • /
    • 1998
  • 리모트 수소 플라즈마에 의한 Si 웨이퍼 표면 위의 Fe 불순물의 제거효과를 조사하였다. 세정시간 10분 이하와 rf-power 100W이하의 범위에서 최적 공정조건은 각각 1분과 100W이였으며, 플라즈마 노출시간이 짧을수록, rf-power가 증가할수록 Fe제거 효과가 더 향상되는 것으로 나타났다. 또한, 고압보다는 저압 하에서 Fe 제거효과가 더 우수하였는데, 저압 하에서는 $\textrm{H}_2$ 유량이 20sccm, 고압 하에서는 60sccm일 때 Fe 제거효과가 가장 우수하였다. 플라즈마 세정 직후의 열처리는 금속오염의 제거효과를 향상시켰으며, $600^{\circ}C$에서 최상의 효과를 얻을 수 있었다. AFM 분석결과에 의하면 표면 거칠기는 플라즈마 세정에 의하여 30-50% 향상되었는데, 이것은 Fe 오염물과 더불어 Si 표면의 particle이 제거된 데 기인하는 것으로 생각된다. 또한 본 논문에서는 수소 플라즈마에 의한 Si 웨이퍼 표면의 Fe 제거기구에 관해서도 자세히 고찰하였다.

  • PDF

열플라즈마에 의한 TiO2-xNx의 합성 및 광촉매 특성 비교 (Synthesis of TiO2-xNx Using Thermal Plasma and Comparison of Photocatalytic Characteristics)

  • 김민희;박동화
    • 공업화학
    • /
    • 제19권3호
    • /
    • pp.270-276
    • /
    • 2008
  • $TiO_2$의 가장 큰 특징은 광촉매적 특성을 들 수 있으나 순수한 $TiO_2$는 자외선 영역에서만 활성을 보이는 단점이 있다. 단점을 보완하고자 본 연구에서는 초고온, 고활성을 이용한 열플라즈마 공정으로 질소가 도핑된 $TiO_2$를 합성하여 $TiO_2$의 광촉매적 특성을 높이고자 하였다. 직류 플라즈마 제트를 이용하여 비금속이온인 질소와 반응 가스인 산소를 $TiCl_4$와 함께 플라즈마 반응기 안에서 반응시켜 질소가 도핑된 $TiO_2$ 나노 분말을 합성하였다. 합성 조건으로 질소의 유량을 변화하였다. 합성 변수에 따른 입자의 상조성, 크기를 분석하였고 아세트알데히드와 곰팡이를 광분해하는 실험을 통해 광촉매 활성을 살펴보았다. 한편 $TiO_2$의 분말 상태와 코팅된 상태의 광촉매 특성을 비교하고자 합성한 분말의 스핀 코팅과 PLD (Pulsed Laser Deposition)을 통해 $TiO_2$를 코팅하였다. 아세트알데히드 분해 실험의 결과 질소가 도핑된 $TiO_2$ 분말의 경우가 순수한 $TiO_2$ 분말에 비해 가시영역에서의 광촉매 활성이 두 배 이상 뛰어난 것을 확인하였으며, 곰팡이 분해 실험 결과 역시 질소가 도핑된 $TiO_2$ 분말에 곰팡이가 분해되는 것을 확인하였다. 분말과 필름을 제조하여 메틸렌블루 광분해 실험한 결과 분말의 경우 100% $TiO_2$입자가 메틸렌블루 분해에 이용되며, 반면 스핀 코팅의 경우 바인더의 함량 때문에 20~30%의 $TiO_2$만이 분해에 이용되기 때문에, 분말의 경우 초기 30 mL 메틸렌블루를 한번에 분해할 수 있었다.