• Title/Summary/Keyword: particle coagulation

Search Result 153, Processing Time 0.028 seconds

Coagulation of Cationic Rosin Emulsion and its Effect on Ink Receptivity of Coating Layer (양이온성 로진 에멀션의 응결현상이 도공층의 잉크흡수성에 미치는 영향)

  • 박철웅;이학래
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.3
    • /
    • pp.74-83
    • /
    • 1998
  • The phenomenon of decrease in sizing efficiency when the stock temperature is increased is well recognized as summer sizing, and this is believed to be caused by uneven distribution of sizing agents on paper surface most often incurred by coagulation of sizing agents. When unevenly sized paper is used as coating base stock, nonuniform consolidation of the coating layer may result, which, in turn, causes uneven distribution of binder on coating surface. This causes nonuniform ink absorption to produce print mottle. In this study the effects of simple or polymeric electrolytes, storage temperature and time on the coagulation of cationic dispersed rosin size were investigated using a turbidity measurement method which was verified to correlate well with the particle size of rosin emulsion or its coagulates. Handsheets sized with rosin dispersions coagulated under various conditions were prepared and their sizing degree and coated paper properties including gloss and ink density were examined. The relationship between the sizing nonuniformity of coated papers and its ink absorption property was evaluated. Turbidity of rosin emulsion increased as the storage temperature and time were increased. Addition of simple or polymeric electrolytes caused reduction in $zeta$ -potential of the rosin dispersion and accelerated the coagulation tendency substantially. Reversion of the $zeta$ -potential of rosin dispersion, however, did not occur when coagulation was induced with simple electrolytes. On the other hand, addition of an anionic polyelectrolyte reversed the $zeta$ -potential of the flocculated rosin dispersion. This indicated that electrical double layer compaction and bridging flocculation were coagulation mechanisms for simple and polymeric electrolytes, respectively. Sizing degree decreased as coagulation of rosin was increased. Paper gloss, ink gloss and ink density were increased when sizing degree of base stock was increased most probably due to prevention of base paper swelling and increased binder migration to coating surface. This suggested that uneven printing ink density occurred when uneven sizing development was induced by coagulation of rosin particles.

  • PDF

The Evaluation of Fouling Mechanism on Cross Flow Precoagulation-UF Process (십자형 응집-UF 막분리 공정 적용시 전처리 응집조건에 따른 막오염 메카니즘 규명)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.639-645
    • /
    • 2008
  • The objectives of this research are to (1) observe changes in particle size distribution due to formation of microflocs during coagulation process (2) identify the membrane fouling potential on cross flow system (3) investigate the mechanism of membrane fouling. The rate of flux decline for the hydrophobic membrane was significantly greater than for the hydrophilic membrane, regardless of pretreatment conditions. The pretreatment of the raw water significantly reduced the fouling of the UF membrane. Also, the rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane. That is, during the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation not only improved dissolved organics removal efficiency but also flux recovery efficiency.

Effective Control of fine Particles Using an Electrostatic Coagulation Between Particle and Water Droplet (입자와 액적간의 정전기적 응집을 통한 미세입자의 효율적인 제어)

  • Lee, Myong-Hwa;Kim, Sang-Bum;Hwang, You-Seong;Kim, Jong-Ho;Kim, Gyung-Soo
    • Journal of ILASS-Korea
    • /
    • v.11 no.2
    • /
    • pp.98-104
    • /
    • 2006
  • A charged droplet scrubber was introduced to remove visible smokes generated in many industrial facilities. Lab-scale and field tests were conducted in this study. The system consists of a corona discharger to effectively charge the fine particles, fellowed by an electrostatic chamber to promote coagulation between charged fine particles and oppositely charged droplets and a demister to remove resultant particles. Overall collection efficiency, 98.4% was obtained from a lab-scale test, when a high voltage was applied to an ionizer and a charged droplet scrubber. Field tests also show the high collection efficiencies, 93.5% with one stage and 99.4% with two stage system. This system can be used to increase the collection efficiency of the conventional air pollution control devices to satisfy the national emission standard.

  • PDF

The Characterization of Floc Formation Under Various Pre-coagulation Conditions (응집-막분리 공정 적용시 전처리 응집조건에 따른 용존성 유기물 상(相)변화 특성)

  • Jung, Chul-Woo;Son, Hee-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1139-1145
    • /
    • 2008
  • The objectives of this research are to investigate the mechanism of coagulation affecting UF and find out the optimum conditions of the combined of coagulation with UF membrane filtration for NOM removal. During the mixing period, substantial changes in particle size distribution occurred under rapid and slow mixing condition due to the simultaneous formation of microflocs and NOM precipitates. Therefore, combined pretreatment using coagulation (both rapid mixing and slow mixing) improved dissolved removal efficiency. Also, for combined coagulation to membrane process, flux reduction rate showed lower than only UF process. The rate of flux decline for the hydrophobic membrane was considerably greater than for the hydrophilic membrane. Applying coagulation process before membrane filtration showed not only reducing membrane fouling, but also improving the removal of dissolved organic materials that might otherwise not be removed by the membrane.

Characteristics of TiO2 Particle Generation and Transport in Diffusion Flame Reactor (확산 화염 반응기에서의 TiO2 입자생성 및 전달현상)

  • Choi, Sang-Keun;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.255-260
    • /
    • 2002
  • We prepared the nano-sized $TiO_2$ particles by the diffusion flame reactor and investigated the effects of several process variables on the generation and transport properties of $TiO_2$ particle. As the length from the tip of diffusion flame reactor increases, the size of $TiO_2$ particle increases by the coagulation between particles. The structure of $TiO_2$ particles prepared is almost found to be anatase. It was found that the $TiO_2$ particle size depends more largely on the change of reactor temperature than on the change of inlet $TiCl_4$ concentration.

  • PDF

Influencing Factors on NOM Removal using Blended Coagulants (혼합응집제에 의한 자연유기물질 제거에 미치는 영향 인자)

  • 명복태;우달식;최종헌;문철훈;이윤진;조영태;조관형;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.96-103
    • /
    • 2001
  • This study was carried out to investigate the major factors for the removal of NOMs (Natural Organic Matters) by alum ferric chloride and blended coagulants that consisted of alum and ferric chloride. Investigated factors were pH, the dosage of coagulant, alkalinity, hardness and bloc strength. The particle size contained in the test water came from the Han River was also measured. DOC(Dissolved Organic Carbon) removal at pH 6 was two to three times higher than at pH 8.5. The blended coagulant showed 9 to 10 percent higher DOC removal efficiency and 2 to 4 percent higher turbidity under the same condition. Alkalinity consumption of alum, ferric chloride and blended coagulant was 81%, 90% and 86% of theoretical value, respectively. The limit concentration of alkalinity to avoid pin floe was 10 mg $CaCO_3/L$ when alum was used. Hardness had no apparent effect on coagulation. The residual turbidity and $UV_{254}$ showed a tendency of increasing with floc strength($sec^{-1}$) increase. The order of floe strength was the following; alum >blended coagulant > ferric chloride. The particle counter test showed 89 percent of the small particle size(SPS, $1~5{\;}{\mu}textrm{m}$) and 11 percent of the medium to large particle size(M.LPS, $5~125{\;}{\mu}textrm{m}$). At PH7.85, the particle removal efficiencies of SPS($1~5{\;}{\mu}textrm{m}$) and M.LPS($5~125{\;}{\mu}textrm{m}$) in the coagulation process were 81% and 95%, respectively.

  • PDF

Changes in the Ångstrom Exponent during Aerosol Coagulation and Condensation

  • Jung, Chang H.;Lee, Ji Yi;Kim, Yong P.
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.304-313
    • /
    • 2012
  • In this study, the ${\AA}$ngstrom exponent for polydispersed aerosol during dynamic processes was investigated. Log-normal aerosol size distribution was assumed, and a sensitivity analysis of the ${\AA}$ngstrom exponent with regards the coagulation and condensation process was performed. The ${\AA}$ngstrom exponent is expected to decrease because of the particle growth due to coagulation and condensation. However, it is difficult to quantify the degree of change. In order to understand quantitatively the change in the ${\AA}$ngstrom exponent during coagulation and condensation, different real and imaginary parts of the refractive index were considered. The results show that the ${\AA}$ngstrom exponent is sensitive to changes in size distribution and refractive index. The total number concentration decreases and the geometric mean diameter of aerosols increase during coagulation. On the while, the geometric standard deviation approaches monodispersed size distribution during the condensation process, and this change in size distribution affects the ${\AA}$ngstrom exponent. The degree of change in the ${\AA}$ngstrom exponent depends on the refractive index and initial size distribution, and the size parameter changes with the ${\AA}$ngstrom exponent for a given refractive index or chemical composition; this indicates that the size distribution plays an important role in determining the ${\AA}$ngstrom exponent as well as the chemical composition. Subsequently, this study shows how the ${\AA}$ngstrom exponent changes quantitatively during the aerosol dynamics processes for a log-normal aerosol size distribution for different refractive indices; the results showed good agreement with the results for simple analytic size distribution solutions.

Comparison of the PO43- Ion Removal Efficiency Using Various PAC Coagulant Types in Sedimentation and Flotation Processes (침전 및 부상 공정에서 PAC 응집제 종류별 PO43- 이온 제거 효율 비교)

  • Jeong-Hak Choi;Ju-Seop Kim;Jong-Won Park;Seong-Kee Min;Hye-Yeon Lee;Chang-Han Lee
    • Journal of Environmental Science International
    • /
    • v.33 no.9
    • /
    • pp.667-674
    • /
    • 2024
  • In the present study, we aimed to determine the optimal polyaluminum chloride (PAC) dosage in raw water based on the PO43--P concentration using PAC coagulants with aluminum concentrations of 10%, 12%, and 17%. The correlation between the Al/P molar ratio and the removal efficiency of aggregated Al-PO43--P flocs was evaluated using sedimentation and flotation processes. As the PO43--P concentration in the raw water increased, the Al/P molar ratio gradually decreased from 6.14 to 1.98. The Al/P molar ratio of PAC formulations with higher aluminum contents showed a decreasing trend in the following order: PAC 17% < PAC 12% < PAC 10%. An increase in the Al/P molar ratio led to a slight increase in the average particle size of Al-PO43--P flocs formed during the coagulation process. At optimal Al/P molar ratios, PO43--P removal efficiency ranged from approximately 80% to 93% for both the coagulation/precipitation and coagulation/flotation processes. The coagulation/flotation process exhibited a slightly higher PO43--P removal efficiency than coagulation/precipitation.