• Title/Summary/Keyword: particle attrition

Search Result 55, Processing Time 0.027 seconds

Particle Size and Piezoelectric Characteristics of PNW-PMN-PZT Ceramics as a Function of Attrition Milling process. (PNW-PMN-PZT 세라믹스의 Attrition Milling에 따른 입도분석 및 압전특성)

  • Lee, Sang-Ho;Yoo, Ju-Hyun;Oh, Dong-On;Ryu, Sung-Lim;Hong, Jae-Il;Chung, Kwang-Hyun;Jung, Moon-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.332-335
    • /
    • 2003
  • Particle size and piezoelectric characteristics of PNW-PMN-PZT ceramics with the variations in attrition milling conditions were investigated for the piezoelectric transformer application. Particle size and distribution were decreased with increasing milling time. Dielectric constant (${\varepsilon}r$), electromechanical coupling factor (kp), mechanical quality factor (Qm) and density showed the optimum value of 1563, 0.53, 2342, 7.63, respectively at 7h milling time.

  • PDF

Attrition Characteristics of Korean Antracite Ash in Fluidized Bed Combustors (유동층 연소로에서 국내탄 회재의 마모 특성)

  • Lee, See Hoon;Kim, Sang Done;Kim, Jae Sung;Lee, Jong Min
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.547-551
    • /
    • 2006
  • In the reactor following the American standard test method (ASTM) D5757-95 and lab-scale fluidized bed combustor, the attrition characteristics of sand and ash of Korean anthracite were investigated. The attrition characteristics, such as particle size distribution of fly ash, attrition rate, and attrition ratio etc, were studied with variation of gas velocities. The particle attrition of ash was more active than sand which was generally used as a fluidized material and also the attrition index of ash taken by ASTM D5757-95 was 5 times higher than that of sand. The formation of fine particles continuously occurred due to particle attrition with increasing gas velocities. The following equation has been suggested for attrition rate of ash. $$\frac{dW}{dt}=-3.18{\times}10^{-7}(U-U_{mf})W$$.

Attrition Characteristics in an Advanced Gasifier with Swirl Injection (접선 방향의 기체 주입에 의한 입자 마모 특성 연구)

  • Lee, See Hoon;Park, Chan Seung;Lee, Jae Goo;Kim, Jae Ho
    • Applied Chemistry for Engineering
    • /
    • v.19 no.3
    • /
    • pp.295-298
    • /
    • 2008
  • In the reactor for the american standard test method (ASTM) D5757-95 with swirl injection nozzles, the attrition characteristics of sand was investigated. The change of particle size distribution and weight of fine particles were compared to identify the effect of swirl injection nozzle on attrition. The fine particles due to particle attrition increased with increasing gas velocities. The weight of fine particles due to jet attrition was changed with angle of swirl injection nozzle. The fine particles decreased with decreasing the angle of swirl injection nozzle. Also, the change of particle size distribution increased with increasing the number of swirl injection nozzles at the same flow rate.

Attrition Characteristics of Catalysts for a High Efficiency Water Gas Shift Process (고효율 수성가스 공정을 위한 촉매 마모 특성)

  • Jo, Jun Beom;Kim, Jae Ho;Lee, See Hoon
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.111-114
    • /
    • 2010
  • In the attrition reactor for the American Society for Testing and Materials (ASTM) D5757-95, the attrition characteristics of catalysts for water gas shift reaction were investigated. The effects of attrition characteristics of low temperature shift catalysts (LTS) and high temperature shift catalysts (HTS) on fluidization phenomena and average particle size were investigated and compared with the attrition characteristics of sand particles. The particle size of catalysts was decreased and particle size distribution in attrition tube was changed due to the effect of gas injection. About 40~50 wt% samples of original catalyst particles were entrained and lost. The amount of fly ash of LTS catalyst was less than that of HTS. Also, the weight of entrained particles which had original particle size of $212{\sim}300{\mu}m$ was lower than any other cases.

The Effect of Fluidized-Bed Variables on Attrition of Solid Particles (유동층 공정변수의 고체입자 마모에 미치는 영향)

  • Moon, Young-Sub;Yi, Chang-Keun;Son, Jae-Ek;Ryu, Chung-Keol;Choi, Jeong-Hoo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.603-608
    • /
    • 2005
  • This study was conducted to investigate particle attrition characteristics in a gas desulfurization using zinc titanate sorbent in a 0.035 m i.d. by 1.34 m height gas fluidized bed reactor. Gas jetting from the distributor and bubbling in the gas fluidized bed were found to be the main causes of particle attrition. The experiment was carried out under a slow attrition rate condition to compare the performance of the batch reactor to that of a continuous reactor. The attrition index (AI) and corrected attrition index (CAI) were measured at various the gas velocity, temperature, pressure, and bed weight, in the gas fluidized bed, during the dexulfurization process. The AI (5) and CAI (5) decreased as the bed weight increased. Particle destruction occurred when the particles started to experience physical fatigue under specific impacts over several iterations. AI (5) and CAI (5) also increased as relative humidity, gas velocity and pressure increased, and as temperature decreased. Particle attrition was mainly affected by gas jetting from the distributor, and abrasion resulted in smaller particles than fragmentation did.

Reactivity and Attrition Resistance of Three Oxygen Carrier Particles for Chemical-Looping Combustor (매체순환식 가스연소기 적용을 위한 세 가지 산소공여입자들의 반응성 및 내마모성)

  • Ryu, Ho-Jung;Jin, Gyoung-Tae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.3
    • /
    • pp.208-219
    • /
    • 2004
  • To find a suitable oxygen carrier particle for a 50kW chemical-looping combustor, which was designed and installed to demonstrate continuous oxidation and reduction, three oxygen carrier particles(NiO/bentonite, $NiO/NiAl_2O_4$, $CoO_x/CoAl_2O_4$) were prepared. The reactivity and the attrition resistance of particles were measured and investigated by a thermo-gravimetrical analyzer and an attrition test apparatus respectively. From the viewpoints of oxygen transfer capacity, optimum reaction temperature(operating temperature range), reaction rate, carbon deposition rate, and attrition resistance, NiO/bentonite particle showed better performance than the other particles, therefore we selected NiO/bentonite particle as an optimum oxygen carrier particle.

The Attrition and Calcination Characteristics of Domestic Limestones for In-Situ Desulfurization in Circulating Fluidized Bed Boilers (순환유동층 로내 탈황을 위한 국내 석회석의 마모 및 소성 특성)

  • Kim, Ye Bin;Kang, Seo Yeong;Seo, Su Been;Keel, Sang In;Yun, Jin Han;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.687-694
    • /
    • 2019
  • In order to investigate the behavior of limestones which have been usually used for in-situ desulfurization reaction in circulating fluidized bed combustors, the attrition characteristics and calcination reactions of domestic limestones were analyzed in this study by using a thermogravimetric analyzer and an ASTM D5757-95 attrition tester. The average size distribution of limestones in circulating fluidized bed boilers have to be changed due to the attrition of particle-particle and particle-reactor wall and the calcination reaction. Domestic limestones might be used in commercial circulating fluidized bed boilers, but the attrition behaviors and particle size changes of limestones were varied. In calcination experiments at $850^{\circ}C$, the calcination reaction were varied with limestone samples. The calcination reaction time increased with an increase of particle size. Also, fine particles generated the attrition test of calcined limestone was 20% higher than those generated the attrition test of original limestone.

Microstructural and Piezoelectric Characteristics of PSN-PMN-PZT Ceramics Produced by Attrition Milling

  • Juhyun Yoo;Sukkyu Min;Jaeil Hong;Sungjae Suh;R, Soonchul-U
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.3
    • /
    • pp.18-23
    • /
    • 2001
  • For the piezoelectric transformer application, Pb(Sb$\_$1/2/ Nb$\_$1/2/)O$_3$-Pb(Zr,Ti)O$_3$ ceramics were produced by attrition milling. Microstructural, dielectric and piezoelectric characteristics of the ceramics were investigated as a function of milling time. The particle size and grain size decreased while dielectric constant, density and mechanical quality factor (Q$\_$m/) increased with milling time. Temperature coefficient of resonant frequency (TCf$\_$r/) was shifted to positive side with increasing milling time. The attrition milling process proved to be one of the effective routes to produce transformers for high power application.

  • PDF

Attrition Characteristics of WGS Catalysts for SEWGS System (SEWGS 시스템을 위한 WGS 촉매들의 마모특성)

  • Ryu, Hojung;Lee, Dongho;Lee, Seungyong;Jin, Gyoungtae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.122-130
    • /
    • 2014
  • Attrition characteristics of WGS catalysts for pre-combustion $ CO_2$ capture were investigated to check attrition loss of those catalysts, to check change of particle size distribution during attrition tests, and to determine solid circulation direction of WGS catalysts in a SEWGS system. The cumulative attrition losses of two catalysts increased with increasing time. However, attrition loss under humidified condition was lower than that under non-humidified condition case for long-term attrition tests. Between two catalysts, attrition loss of PC-29 catalyst was higher than that of commercial catalyst for long-term attrition tests. However, the commercial catalyst generated much more fines than PC-29 catalyst during attrition. Therefore, we conclude that the PC-29 catalyst is more suitable for fluidized bed operation if we take into account the separation efficiency of cyclone. Based on the results from the tests for the effect of humidity on the attrition loss, we selected solid circulation direction from SEWGS reactor to regeneration reactor because the SEWGS reactor contains more water vapor than regeneration reactor.

The Study on Attrition Resistance of ZnO/natural-zeolite/Fe$_2$O$_3$ Desulfurization Sorbents with CaO for Hot Gas Clean-up (산화칼슘이 첨가된 ZnO/Natural-zeolite/Balho Kim/Fe$_2$O$_3$ 탈황제의 내마모성특성 연구)

  • 정용길;박노국;이종대;전진혁;류시옥;이태진
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.75-81
    • /
    • 2004
  • ZZFCa sorbents for hot gas desulfurization in IGCC were prepared by adding calcium oxide to ZZF sorbent in order to improve its attrition resistance in this study. ASTM attrition test for the sorbent was performed at several different weight percentages of CaO to investigate the attrition characteristics of ZBFCa sorbents as a function of CaO content. Attrition index of ZZF without CaO was 28.3% and its collected attrition index was 10.8%. ZZFCa-3 containing 3 wt% CaO showed the lowest attrition index (AI=17.3%, CAI=8.8%) in the test. From the results of SEM morphologies and particle size distribution measurements, ZZFCa-3 maintained a fine shape and a desirable average particle size even after attrition test. In the experiments of sulfidation/regeneration for ZZFCa-3 sorbent concentration of hydrogen sulfide in coal gas was lowered from 10000 ppm to below 1 ppm. Sulfur removing capacity was about 28.8 g S/100 g sorbent. Neither formation of CaSO$_4$ was observed in XRD measurement nor SO$_2$ slippage was observed during sulfidation process.