• 제목/요약/키워드: partial resistance

검색결과 441건 처리시간 0.034초

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium

  • Suzuki, Ginga;Shimizu, Satoshi;Torii, Mana;Tokue, Ai;Ying, Guo;Yoshinari, Masao;Hoshi, Noriyuki;Kimoto, Katsuhiko;Miura, Hiromi;Hayakawa, Tohru;Ohkubo, Chikahiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.369-375
    • /
    • 2020
  • PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

신뢰성공학에 근거한 하중-강도계수 설계법과 부분안전계수의 개념 및 적용 (The Concepts and the Applications of Load and Resistance Factor Design and Partial Safety Factor Based on the Reliability Engineering)

  • 유연식;김태완;김종인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.309-314
    • /
    • 2007
  • Recently, the LRFD and the PSF based on structural reliability assessment have been applied to NPP designs in behalf of the conventional deterministic design methods. In the risk-informed structural integrity, it is especially possible to optimize design procedures considering cost, manufacturing and maintenance because the structural reliability concepts have confirmed the reliability for which a designer aims. Generally, in order to evaluate the PSF, the LRFD which is the design concept for evaluating safety factors respectively on the limit state function including load and resistance. This study certifies the concept and its applications of the PSF using the LRFD based on the structural reliability engineering.

  • PDF

ITO 박막의 공정변수에 따른 특성 연구 (Dependance of the Process Parameters on the Characteristic of the ITO Thin Films)

  • 김소라;서정은;김상호
    • 한국표면공학회지
    • /
    • 제37권3호
    • /
    • pp.158-163
    • /
    • 2004
  • ITO thin film was deposited on the glass by RF magnetron sputtering. Dependance of the process parameters such as thickness, target-to-substrate distance, substrate temperature and oxygen partial pressure on the transmittance and electrical resistance of ITO film were investigated. The deposition conditions for getting better optical and electrical ITO characteristics were the 1800-$2300\AA$ thickness, 65mm substrate-to-target distance, $350^{\circ}C$ substrate temperature and 8% oxygen partial pressure. At these conditions, the transmittance and sheet resistance of the ITO film were 83.3% and 77.86Ω/$\square$, respectively.

서남해안 해상풍력단지 말뚝기초의 부분안전계수 (Partial Safety Factor of Offshore Wind Turbine Pile Foundation in West-South Mainland Sea)

  • 윤길림;김선빈;권오순;유무성
    • 대한토목학회논문집
    • /
    • 제34권5호
    • /
    • pp.1489-1504
    • /
    • 2014
  • 본 논문은 국내 서남해안 해상풍력발전 하부기초설계 시 신뢰성 기반의 한계상태설계법 적용을 위한 말뚝기초의 부분안전계수를 제안하고자 한다. 우선, 해상풍력관련 국제 설계기준서인 IEC, GL, DNV, API, ISO, EUROCODE 등에서 제시한 다양한 부분안전계수 및 저항계수를 비교 분석하였다. 그리고 부안-영광 및 새만금 해역의 서남해안 해상풍력단지의 지반조사 결과를 가지고 불확실성 분석을 수행하였다. 불확실성 분석 결과를 토대로 신뢰성해석을 수행하여 지반정수에 대한 부분안전계수를 산정하였으며, 서남해안 지역의 해상풍력 말뚝기초의 부분안전계수는 1.3으로 평가되었다. 본 논문에서 제안된 부분안전계수는 서남해안에서의 지반조사 결과를 근거로 산정된 것이므로 기타 광역단위 해역에 활용하기 위해서는 추가적인 조사 및 지반정수에 대한 불확실성 분석을 통해 보정이 필요하다고 판단된다.

단상 컨버터의 부분공진 회로 (Single-Phase converter with partial resonant circuit)

  • 이현우;곽동걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.129-131
    • /
    • 1993
  • Power conversion system of high performance requires high switching frequency power converter. In order to minimize commutation stress and switching losses, in this paper, AC-DC converter is embedded a partial resonant DC-Link circuit with the object of ZVCS(zero voltage switching and zero current switching). The partial resonant occurs just before converter switch operates. Thus, VA ratings of the elements and their dissipations due to effective series resistance (ESR) are very low. Some simulative results on computer are included to confirm the validity of the analytical results.

  • PDF

Linkage of the Kanamycin Resistance Gene with the Streptothricin Resistance Gene in Staphylococcus aureus SA2

  • Shin, Chul Kyo;Sung Hwan Im;Woo Koo Kim;Kyung Bo Moon
    • Journal of Microbiology and Biotechnology
    • /
    • 제6권3호
    • /
    • pp.219-220
    • /
    • 1996
  • The pKH2 isolated from the multidrug-resistant Staphylococcus aureus SA2 is a 40.98-kb plasmid and mediates resistance to ampicillin, clindamycin, erythromycin, kanamycin, and streptomycin. The 3.4-kb HindIII fragment conferring kanamycin resistance was cloned from the pKH2 into pBluescriptII $KS^+$ and partial sequence determination of that fragment was carried out. Sequence analysis revealed that the kanamycin resistance gene which encoded aminoglycoside 3'-phosphotransferase was linked to the streptothricin resistance gene. But a nonsense mutation was found in the streptothricin resistance gene and this mutation resulted in a truncated protein of streptothricin acetyltransferase. Homology comparison with nucleotide sequence databases revealed that the 3.4-kb HindIII fragment of pKH2 had been derived not from S. aureus but from Gram-negative Campylobacter coli.

  • PDF

Design models for predicting the resistance of headed studs in profiled sheeting

  • Vigneri, Valentino;Hicks, Stephen J.;Taras, Andreas;Odenbreit, Christoph
    • Steel and Composite Structures
    • /
    • 제42권5호
    • /
    • pp.633-647
    • /
    • 2022
  • This paper presents the results from reliability analyses of the current Eurocode 4 (EN 1994-1-1) and AISC 360-16 design models for predicting the resistance of headed stud shear connectors within profiled steel sheeting, when the ribs are oriented transverse to the supporting beam. For comparison purposes, the performance of the alternative "Luxembourg" and "Stuttgart" model were also considered. From an initial database of 611 push-out tests, 269 cases were included in the study, which ensured that the results were valid over a wide range of geometrical and material properties. It was found that the current EN 1994-1-1 design rules deliver a corrected partial safety factor γM* of around 2.0, which is significantly higher than the target value 1.25. Moreover, 179 tests fell within the domain of the concrete-related failure design equation. Notwithstanding this, the EN 1994-1-1 equations provide satisfactory results for re-entrant profiled sheeting. The AISC 360-16 design equation for steel failure covers 263 of the tests in the database and delivers 𝛾M*≈2.0. Conversely, whilst the alternative "Stuttgart" model provides an improvement over the current codes, only a corrected partial safety factor of 𝛾M*=1.47 is achieved. Finally, the alternative "Luxembourg" design model was found to deliver the required target value, with a corrected partial safety factor 𝛾M* between 1.21 and 1.28. Given the fact that the Luxembourg design model is the only model that achieved the target values required by EN 1990, it is recommended as a potential candidate for inclusion within the second generation of Eurocodes.

Partial cross-resistance between Strongyloides venezuelensis and Nippostrongylus brasiliensis in rats

  • Baek, Byeong-Kirl;Islam, M.-Khyrul;Kim, Jin-Ho;Lee, John-Wha;Hur, Jin
    • Parasites, Hosts and Diseases
    • /
    • 제37권2호
    • /
    • pp.101-107
    • /
    • 1999
  • Rats were immunized through an initial infection with 1,000 filariform larvae (L3) of Nippostrongylus brasiliensis and after complete expulsion of worms they were challenged with 1,000 L3 of Strongyloides venezuelensis to investigate whether cross-resistance developed against a heterologous parasite. Nippostrongylus brasiliensis immunized rats developed a partial cross-resistance against S.venezuelensis migrating larvae (MSL3) in the lungs and adult worms in the small intestine. The population of MSL3 in the lungs were significantly lower (p<0.05) in immunized rats($22.0{\;}{\pm}{\;}7.4$) compared with controls ($105.0{\;}{\pm}{\;}27.6$). The populations of adult worms, egg output and fecundity were initially decreased but from day 14 post-challenge they did not show any significant difference between immunized and control rats. However, the length of worm in immunized rat was revealed as retardation. Peripheral blood eosinophilia was significantly decreased (P<0.05) on day 7 post-challenge and then gradually increased which peaked on da 42 post-challenge when most of the worms were expelled. these results suggest that peripheral blood eosinophilia is strongly involved in the worm establishment and expulsion mechanisms.

  • PDF

Relationship between hematologic parameters related to systemic inflammation and insulin resistance-associated metabolic parameters in women with polycystic ovary syndrome

  • Minkyung Cho;Suji Kim;Sungwook Chun
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제50권3호
    • /
    • pp.206-212
    • /
    • 2023
  • Objective: The aim of the present study was to evaluate the associations between hematologic parameters related to systemic inflammation and insulin resistance-associated metabolic parameters in women with polycystic ovary syndrome (PCOS). Methods: Eighty-two women between the ages of 18 and 35 years who were diagnosed with PCOS were included in this study. A 2-hour 75-g oral glucose tolerance test (OGTT) was administered to all study participants; fasting and postprandial glucose and insulin levels were measured simultaneously during the 2-hour OGTT. Hematologic parameters were derived from a standard complete blood count and a differential count of fasting-state blood samples. The correlations between hematologic parameters and insulin resistance-associated clinical and metabolic parameters were evaluated using the Spearman rank correlation and partial correlation coefficients. Hematologic parameters related to systemic inflammation were compared between the two groups, categorized by the presence or absence of insulin resistance. Results: Significant differences in the absolute neutrophil count, absolute monocyte count, platelet count, and neutrophil-lymphocyte ratio were found between the insulin-resistant group and insulin-nonresistant group. Correlation analysis found that all hematological parameters, except for the platelet-lymphocyte ratio, were associated with at least one insulin resistance-associated metabolic parameter. However, these significant correlations between hematological and metabolic parameters were attenuated after controlling for the effects of other covariates using partial correlation analysis. Conclusion: The association between hematologic parameters indicative of systemic inflammation and insulin resistance-associated metabolic parameters seems to be strongly influenced by other anthropometric covariates in women with PCOS.

Hemodynamics of a Connecting conduit Between the Left Ventricle and the Left Decending Coronary Artery

  • Shim, Eun-Bo;Sah, Jong-Yub
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권2호
    • /
    • pp.20-29
    • /
    • 2003
  • A new treatment for coronary artery occlusive disease is being developed in which a shunt or conduit is placed directly connecting the left ventricle with the diseased artery at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Simulation results indicate that in complete LAD occlusion, flow can be returned to approximately 65% of normal if the conduit resistance is equal for forward and reverse flow, increasing to 80% in the limit in which backflow resistance is infinite. Increases in flow rate produced by asymmetric flow resistance are considerably enhanced in the case of a partial LAD obstruction since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle("steal") during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but leads to considerable augmentation when the resistance is asymmetric. These results suggest that an LV-LAD conduit will be beneficial when stenosis resistance(Rst) > 27 PRU if resistance is symmetric.

  • PDF