• Title/Summary/Keyword: partial plastic

Search Result 421, Processing Time 0.026 seconds

Inelastic behavior of standard and retrofitted rectangular hollow sectioned struts -I: Analytical model

  • Boutros, Medhat K.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.5
    • /
    • pp.491-504
    • /
    • 2000
  • This paper is a presentation of a physical model for the elastic-partly plastic behavior of rectangular hollow section pinned struts subjected to static cyclic axial loading and the evaluation of the compressive strength of retrofitted damaged struts. Retrofitting is achieved by welding stiffening plates along the webs of damaged struts. The shape of the elastic and permanent deformations of the strut axis satisfy the conditions at the ends and midspan. Continuous functions of the geometric variables of stress distributions in the yielded zone are evaluated by interpolation between three points along each partly plastic zone. Permanent deformations of the partly plastic region are computed and used to update the shape of the unloaded strut. The necessity of considering geometric nonlinearity is discussed. The sensitivity of the results to the location of interpolation points, the shape of the permanent deformation and material hysteretic properties is investigated.

Study on the palstic green houses depending on regional weather conditions (지역기후특성을 고려한 비닐온실에 관한연구)

  • Woo, Byung Kwan;Lee, Sung;Kim, Se Hwan;Kim, Sam Yeol
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.39-46
    • /
    • 2009
  • Most Plastic Green Houses in Korea are made according the European weather condition, which lead to have very low solar energy efficiency. Moreover, the function of green houses, as well as the structure of them, has not changed for Korean weather condition. Therefore, the structure and function of them should adopt the regional weather condition in order to improve the energy efficiency. This paper investigates the current plastic green housesin Korea, and presents an alternative for improving the energy efficiency. The elements of green houses were investigated. When using a partial opaque insulation with a thermal storage body, the difference of indoor air temperature became 20C during daytime, and 5C during night, which will save massive fossil fuels.

Effects of Accelerated Iso-Thermal Aging on Elastic-Plastic Fracture Toughness and Fracture Resistance Curve by Unloading Compliance Method in SA533B Low Alloy Steel (제하 컴플라이언스법에 의한 SA533B강의 $J_1C$ 및 J-R 곡선에 미치는 열시효 영향)

  • 윤한기;차귀준
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.157-165
    • /
    • 1994
  • Effect of an accelerated iso-thermal aging (375 degree C x 66days, 375 degree C x 200days) on elastic-plastic fracture resistance curve were examined in SA533B low alloy steel. Fracture toughness test are conducted by unloading compliance method at room temperature. But the apparent negative crack growth phenomenon, usually arise in partial unloading compliance test. The phenomenon of negative crack growth may be eliminated by the offset technique. There is no effect of aging on J sub(IC) and dJ/da in iso-thermal aged (375 degree C x 66 days) specimen, but there is very little effect in iso-thermal aged (375 degree C x 200 days) specimen.

  • PDF

Considerations for Postoperative Results of Pressure Sores around Buttock Region by Musculocutaneous Flaps and Perforator Flaps (근피피판과 천공지피판을 이용한 둔부 주위 욕창 재건술의 술후 결과에 대한 고찰)

  • Bae, Seong-Hwan;Nam, Su-Bong;Kim, Kyung-Hoon;Lee, Jae-Woo;Oh, Heung-Chan;Choi, Soo-Jong;Bae, Yong-Chan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.815-820
    • /
    • 2011
  • Purpose: Perforator flaps have been widely used for reconstruction of pressure sores because they have many benefits, especially reducing tension. Otherwise in order to prevent recurrence of a pressure sore, sufficient thickness of a flap is desirable, so a musculocutaneous flap is also useful for reconstruction of a pressure sore. Therefore, the authors considered about the postoperative results of reconstruction of pressure sores between using perforator flaps and musculocutaneous flaps. Methods: In this study, 33 patients (46 flaps) who underwent reconstructive operation of pressure sores from January 2007 to February 2011 were reviewed. Patients operated by using perforator flaps were 18 (18 flaps), and musculocutaneous flaps were 17 (28 flaps). We studied postoperative complications and recurrence. Results: We experienced five patients (10 flaps) with complications or recurrences who were operated using musculocutaneous flaps and one patient using a perforator flap. One case using a perforator flap stemmed from dehiscence caused by a urinary fistula occurring in two months after the surgery. Among ten cases using musculocutaneous flaps, one case was caused by total necrosis of flap, five cases by partial necrosis of flap and dehiscence, and four cases by recurrences during follow-up period. Conclusion: Even if more cases were required, it can be more considerable to operate using the perforator flap rather than the musculocutaneous flap to reduce the complication or recurrence of pressure sore.

Usefulness of Oncoplastic Volume Replacement Techniques after Breast Conserving Surgery in Small to Moderate-sized Breasts

  • Yang, Jung Dug;Kim, Min Chul;Lee, Jeong Woo;Cho, Young Kyoo;Choi, Kang Young;Chung, Ho Yun;Cho, Byung Chae;Park, Ho Yong
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.489-496
    • /
    • 2012
  • Background In Korean women, many of whom have small to moderate-sized breasts, it is difficult to cover a partial breast defect using oncoplastic volume displacement techniques after removal of an adequate volume of tissue during oncologic surgery. In such cases, oncoplastic volume replacement techniques are more useful. Methods From January 2007 to December 2011, 104 women underwent a total of 107 breast-conserving surgeries with various kinds of oncoplastic volume replacement techniques. We used latissimus dorsi (LD) myocutaneous flap for cases in which the resection mass was greater than 150 g. In case with a resection mass less than 150 g, we used regional flaps such as a lateral thoracodorsal flap, a thoracoepigastric flap, or perforator flaps such as an intercostal artery perforator (ICAP) flap or a thoracodorsal artery perforator (TDAP) flap. Results The mean age was 46.1 years, and the average follow-up interval was 10.3 months. The patients underwent oncoplastic volume replacement techniques with a lateral thoracodorsal flap (n=9), thoracoepigastric flap (n=7), ICAP flap (n=25), TDAP flap (n=12), and LD flap (n=54). There was one case of congestion in an LD flap, and two cases of fat necrosis in an ICAP flap. Most of the patients were satisfied with the cosmetic results. Conclusions Oncoplastic volume replacement techniques can be reliable and useful for the correction of breast deformity after breast-conserving surgery, especially in patients with small to moderate-sized breasts.

Upper Arm Contouring with Brachioplasty after Massive Weight Loss

  • Han, Hyun Ho;Lee, Min Cheol;Kim, Sang Hwa;Lee, Jung Ho;Ahn, Sang Tae;Rhie, Jong Won
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.271-276
    • /
    • 2014
  • Background As the obese population increases in Korea, the number of patients who are trying to lose weight has been increasing steadily. In these patients, skin laxity and deformation of the body contour occurs, which could possibly be corrected by various body contouring surgeries. Here, we introduce the brachioplasty method and our experience of various body contouring surgeries performed in our center. Methods From November 2009 to August 2011, five cases of brachioplasty were performed. When the patient presented with sagging of the lateral inframammary crease and bat wing deformity in the axilla, extended brachioplasty was performed; in this case, the deformation of the axilla and lateral chest was corrected at the same time. A traditional brachioplasty was performed when contouring was needed only for skin laxity in the upper arm. Results Complications, such as hematomas or nerve injuries, were not evident. Some patients experienced partial wound dehiscence due to tension or hypertrophic scars found during the follow-up. In general, all of the patients were satisfied with the improvement in their upper arm contour. Conclusions Given the demands for body contouring surgery, the number of brachioplasty surgical procedures is expected to increase significantly, with abdominoplasty comprising a large portion of these surgeries. For the brachioplasty procedure, preparation and preoperative consultation regarding design of the surgery by experienced surgeons was important to prevent complications such as nerve damage or hematoma formation.

Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

  • Yang, Jung Dug;Cho, In Gook;Kwon, Joon Hyun;Lee, Jeong Woo;Choi, Kang Young;Chung, Ho Yun;Cho, Byung Chae
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.418-423
    • /
    • 2016
  • Background Skin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute. Methods This prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A), and RapiGraft and split-thickness skin grafting were used on the other side (group B). All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS), a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months. Results The skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082). Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all). However, the groups did not differ significantly in pliability (P=0.155). Conclusions The present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

The effects of optimizing blood inflow in the pedicle on perforator flap survival: A pilot study in a rat model

  • Olariu, Radu;Moser, Helen Laura;Lese, Ioana;Sabau, Dan;Georgescu, Alexandru Valentin;Grobbelaar, Adriaan Ockert;Constantinescu, Mihai Adrian
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.209-216
    • /
    • 2020
  • Background Perforator flaps have led to a revolution in reconstructive surgery by reducing donor site morbidity. However, many surgeons have witnessed partial flap necrosis. Experimental methods to increase inflow have relied on adding a separate pedicle to the flap. The aim of our study was to experimentally determine whether increasing blood flow in the perforator pedicle itself could benefit flap survival. Methods In 30 male Lewis rats, an extended posterior thigh perforator flap was elevated and the pedicle was dissected to its origin from the femoral vessels. The rats were assigned to three groups: control (group I), acute inflow (group II) and arterial preconditioning (group III) depending on the timing of ligation of the femoral artery distal to the site of pedicle emergence. Digital planimetry was performed on postoperative day (POD) 7 and all flaps were monitored using laser Doppler flowmetry perioperatively and postoperatively in three regions (P1-proximal flap, P2-middle of the flap, P3-distal flap). Results Digital planimetry showed the highest area of survival in group II (78.12%±8.38%), followed by groups III and I. The laser Doppler results showed statistically significant higher values in group II on POD 7 for P2 and P3. At P3, only group II recorded an increase in the flow on POD 7 in comparison to POD 1. Conclusions Optimization of arterial inflow, regardless if performed acutely or as preconditioning, led to increased flap survival in a rat perforator flap model.

Choice of recipient vessels in muscle-sparing transverse rectus abdominis myocutaneous flap breast reconstruction: A comparative study

  • Moon, Kyung-Chul;Lee, Jae-Min;Baek, Si-Ook;Jang, Seo-Yoon;Yoon, Eul-Sik;Lee, Byung-Il;Park, Seung-Ha
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • Background Thoracodorsal vessels (TDVs) and internal mammary vessels (IMVs) have both been widely employed as recipient vessels for use in free muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flaps. However, whether TDVs or IMVs are preferable as recipient vessels for autologous breast reconstruction with a free MS-TRAM flap remains controversial. The purpose of this study was to compare the clinical outcomes when TDVs were used as recipient vessels to those obtained when IMVs were used as recipient vessels for autologous breast reconstruction with a free MS-TRAM flap. Methods A retrospective matched-cohort study was performed. We retrospectively reviewed data collected from patients who underwent a free MS-TRAM flap for autologous breast reconstructions after mastectomy between March 2003 and June 2013. After a one-to-one matching using age, 100 autologous breast reconstructions were selected in this study. Of the 100 breast reconstructions, 50 flaps were anastomosed to TDVs and 50 to IMVs. Patient demographics and clinical outcomes including operation time, length of hospital stay, postoperative complications, and aesthetic score were compared between the two groups. Results No statistically significant differences were found between the two groups in patient demographics and clinical outcomes, including the complication rates and aesthetic scores. There were no major complications such as total or partial flap loss in either group. Conclusions The results of our study demonstrate that both TDVs and IMVs were safe and efficient as recipient vessels in terms of the complication rates and aesthetic outcomes.

A population-based study of breast implant illness

  • Magno-Padron, David A.;Luo, Jessica;Jessop, Terry C.;Garlick, Jared W.;Manum, Joanna S.;Carter, Gentry C.;Agarwal, Jayant P.;Kwok, Alvin C.
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.353-360
    • /
    • 2021
  • Background Despite evidence supporting the safety of breast implants, some women associate their implants with adverse health effects and have called this syndrome "breast implant illness." We sought to characterize breast implant illness symptoms and to report how implant removal affects their symptoms. Methods An anonymous 20 question survey was administered to the Facebook group: "UTAH Breast Implant Illness" to characterize the symptoms these women attributed to their breast implants. Several questions allowed us to evaluate how implant removal affected women's symptoms. Results Of the 182 respondents, 97% report that implants negatively affect their health and 95% identify these symptoms with breast implant illness. Ninety-six percent of respondents had implants placed for cosmetic reasons and 51% had silicone implants. The most common symptoms associated with breast implant illness are brain fog (95%), fatigue (92%), joint pain (80%), and hair loss (74%). Sixty percent of respondents learned about breast implant illness from family/friends and/or social media platforms (56%), 40% of respondents had their implants removed, and 97% report relief of their symptoms post-removal (23% complete, 74% partial). Following explantation, there was a significant improvement in all but one reported symptom. An association was found between the number of symptoms reported prior to explantation and the number of symptoms resolving following explantation. Conclusions Breast implant illness is a syndrome characterized by fatigue, decreased focus, hair loss, and joint pain after the placement of breast implants. Nearly all patients report improvement of symptoms after implant removal. Significant efforts should be made to better understand breast implant illness and its etiology.