• Title/Summary/Keyword: partial parity

Search Result 19, Processing Time 0.03 seconds

Metadata Log Management for Full Stripe Parity in Flash Storage Systems (플래시 저장 시스템의 Full Stripe Parity를 위한 메타데이터 로그 관리 방법)

  • Lim, Seung-Ho
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.11
    • /
    • pp.17-26
    • /
    • 2019
  • RAID-5 technology is one of the choice for flash storage device to enhance its reliability. However, RAID-5 has inherent parity update overhead, especially, parity overhead for partial stripe write is one of the crucial issues for flash-based RAID-5 technologies. In this paper, we design efficient parity log architecture for RAID-5 to eliminate runtime partial parity overhead. During runtime, partial parity is retained in buffer memory until full stripe write completed, and the parity is written with full strip write. In addition, parity log is maintained in memory until whole the stripe group is used for data write. With this parity log, partial parity can be recovered from the power loss. In the experiments, the parity log method can eliminate partial parity writes overhead with a little parity log writes. Hence it can reduce write amplification at the same reliability.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

Efficient Partial Parallel Encoders for IRA Codes in DVB-S2 (DVB-S2 IRA Code를 위한 최적 부호화 방법)

  • Hwang, Sung-Oh;Lee, Jai-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11C
    • /
    • pp.901-906
    • /
    • 2010
  • Low density parity check (LDPC) code, first introduced by Gallager and re-discovered by MacKay et al, has attracted researcher's interest mainly due to their performance and low decoding complexity. It was remarkable that the performance is very close to Shannon capacity limit under the assumption of having long codeword length and iterative decoder. However, comparing to turbo codes widely used in the current mobile communication, the encoding complexity of LDPC codes has been regarded as the drawback. This paper proposes a solution for DVB-S2 LDPC encoder to reduce the encoder latency. We use the fast IRA encoder that use the transformation of the parity check matrix into block-wise form and the partial parallel process to reduce the number of system clocks for the IRA code encoding. We compare the proposed encoder with the current DVB-S2 encoder to show that the performance of proposal is better than that of the current DVB-S2 encoder.

Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach (직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법)

  • Park, Tae-Geon;Ryu, Ji-Su;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

A Combining Scheme for Partial Incremental Redundancy based Hybrid Automatic Repeat Request in MIMO Systems (다중 안테나 시스템에서 부분 증분 리던던시 방식 Hybrid ARQ를 위한 결합 기법)

  • Park, Sang-Joon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.19-23
    • /
    • 2010
  • In this paper, we propose a combining scheme for partial IR based hybrid ARQ in MIMO systems. The proposed combining scheme is a symbol-level combining scheme for repeatedly transmitted systematic symbols in partial IR based hybrid ARQ. In this paper, it is shown that the proposed combining scheme can also enhance the detection performance of the parity symbols that are newly transmitted in each retransmission. Simulation results show that the proposed combining scheme significantly improves the performance of the partial IR based hybrid ARQ compared to the cases of the conventional bit-level combining scheme, especially with the ZF detection.

Breastfeeding Adaptation Scale-Short Form for mothers at 2 weeks postpartum: construct validity, reliability, and measurement invariance (산후 2주 축약형 모유수유 적응 측정도구의 구성 타당도, 신뢰도와 측정 불변성)

  • Kim, Sun-Hee
    • Women's Health Nursing
    • /
    • v.26 no.4
    • /
    • pp.326-335
    • /
    • 2020
  • Purpose: This study was conducted to evaluate the construct validity, reliability, measurement invariance, and latent mean differences in the Breastfeeding Adaptation Scale-Short Form (BFAS-SF) for use with mothers at 2 weeks postpartum. Methods: This methodological study was designed to evaluate the validity, reliability, and measurement invariance of the BFAS-SF at 2 weeks postpartum, with data collected from 431 breastfeeding mothers. Confirmatory factor analysis and multi-group confirmatory factor analysis were conducted to assess the factor structure and the measurement invariance across employment status, delivery mode, parity, and previous breastfeeding experience, and the latent mean differences were then examined. Results: The goodness of fit of the six-factor model at 2 weeks postpartum was acceptable. Multi-group confirmatory factor analysis supported strict invariance of the BFAS-SF across employment status and delivery mode. Full configural invariance, full metric invariance, and partial scalar invariance across parity and full configural invariance and full metric invariance across previous breastfeeding experience were supported, respectively. The results for latent mean differences suggested that mothers who were employed showed significantly higher scores for breastfeeding confidence. Mothers who had a vaginal delivery showed significantly higher scores for sufficient breast milk and baby's feeding capability. Multiparous mothers showed significantly higher scores for baby's feeding capability and baby's satisfaction with breastfeeding. Conclusion: The validity and reliability of the BFAS-SF at 2 weeks postpartum are acceptable. It can be used to compare mean scores of breastfeeding adaptation according to employment status, delivery mode, and parity.

Estimation of Daily Milk Yields from AM/PM Milking Records

  • Lee, Deukhwan;Min, Hongrip
    • Journal of Animal Science and Technology
    • /
    • v.55 no.6
    • /
    • pp.489-500
    • /
    • 2013
  • Daily milk yields on test days were estimated using morning or afternoon partial milk yields collected by official agencies and the accuracy of the estimates was determined. Test-day data for milk yields consisted of 3,156,734 records of AM/PM partial milking measurements of 255,437 milking Holstein cows from 3,708 farms collected from December 2008 to April 2013. A linear regression model (LRM) was applied to estimate daily milk yields using alternate AM/PM milk yield records within lactation stages, milking intervals, and parities on every daily milk yield. The alternate statistical approach was a non-linear hierarchical model (NHM) in which Brody's growth function was implemented by reflecting an animal's physiological milk production cycle. When compared with LRM, daily milk yields predicted by the NHM were assumed to be functionally related to day in milk (or lactation) stage, milking intervals, and partial milk yields. Since the results were in terms of accuracies based on comparisons of different statistical models, accuracies of estimates of daily milk yields by NHM were close to those determined by the LRM. The average of these accuracies was 0.94 for AM partial milk yields and 0.93 for PM partial milk yields for first calving cows. However, the accuracies of AM/PM milk yield estimations from cows under a calving stage higher than the first parity were 0.96 and 0.95, respectively. Correlations between the estimated daily milk yields and the actual daily milk yields ranged from 0.96~0.98. These accuracies were lower for unbalanced AM/PM milking intervals and the first calving cows. Overall, prediction of daily milk yields by NHM would be more appropriate than by LRM due to its flexibility under different milk yield-related circumstances, which provides an idea of the functional relationship between milking intervals and days in milk with daily milk yields from statistical viewpoints.

Complexity-Reduced Algorithms for LDPC Decoder for DVB-S2 Systems

  • Choi, Eun-A;Jung, Ji-Won;Kim, Nae-Soo;Oh, Deock-Gil
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.639-642
    • /
    • 2005
  • This paper proposes two kinds of complexity-reduced algorithms for a low density parity check (LDPC) decoder. First, sequential decoding using a partial group is proposed. It has the same hardware complexity and requires a fewer number of iterations with little performance loss. The amount of performance loss can be determined by the designer, based on a tradeoff with the desired reduction in complexity. Second, an early detection method for reducing the computational complexity is proposed. Using a confidence criterion, some bit nodes and check node edges are detected early on during decoding. Once the edges are detected, no further iteration is required; thus early detection reduces the computational complexity.

  • PDF

Partial Preconditioning Approach for the Solution of Detailed Kinetics Problems Based on Sensitivity Analysis (효율적인 상세 반응 기구 해석을 위한 민감도 기반의 부분 음해법)

  • Kang, K.H.;Moon, S.Y.;Noh, J.H.;Won, S.H.;Choi, J.Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.1
    • /
    • pp.17-22
    • /
    • 2008
  • A partly implicit/quasi-explicit method is introduced for the solution of detailed chemical kinetics with stiff source terms based on the standard fourth-order Runge-Kutta scheme. Present method solves implicitly only the stiff reaction rate equations, whereas the others explicitly. The stiff equations are selected based on the survey of the chemical Jaconian matrix and its Eigenvalues. As an application of the present method constant pressure combustion was analyzed by a detailed mechanism of hydrogen-air combustion with NOx chemistry. The sensitivity analysis reveals that only the 4 species in NOx chemistry has strong stiffness and should be solved implicitly among the 13 species. The implicit solution of the 4 species successfully predicts the entire process with same accuracy and efficiency at half the price.

  • PDF

A Low-Complexity CLSIC-LMMSE-Based Multi-User Detection Algorithm for Coded MIMO Systems with High Order Modulation

  • Xu, Jin;Zhang, Kai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.1954-1971
    • /
    • 2017
  • In this work, first, a multiuser detection (MUD) algorithm based on component-level soft interference cancellation and linear minimum mean square error (CLSIC-LMMSE) is proposed, which can enhance the bit error ratio (BER) performance of the traditional SIC-LMMSE-based MUD by mitigating error propagation. Second, for non-binary low density parity check (NB-LDPC) coded high-order modulation systems, when the proposed algorithm is integrated with partial mapping, the receiver with iterative detection and decoding (IDD) achieves not only better BER performance but also significantly computational complexity reduction over the traditional SIC-LMMSE-based IDD scheme. Extrinsic information transfer chart (EXIT) analysis and numerical simulations are both used to support the conclusions.