• Title/Summary/Keyword: partial measurement

Search Result 736, Processing Time 0.029 seconds

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

The Development of HFPD System for Mibile-loading Vehicles (차량탑재형 HFPD의 개발)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A Study on the PD Measurement System for Estimating Reliabilities of Low-voltage Electrical and Electronic Components (저압용 전기전자부품의 신뢰성 평가를 위한 부분방전 측정시스템에 관한 연구)

  • Seo, Hwang-Dong;Snog, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kang, Dong-Sik;Hwang, Don-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.321-322
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement system that has been accepted as an effective and non-destructive technique for estimating reliabilities of low-voltage electrical and electronic components. Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 37.6 mv/pC. In an application test on photo coupler, we could detect 0.1 pC level of partial discharge at the applied voltage of AC 520 $V_{peak}$.

  • PDF

HFPD Characteristic Analysis of Simulated Transformer According To Applied Voltage (인가전압에 따른 모의변압기의 HFPD 특성분석)

  • Kim, Duck-Keun;Im, Young-Sham;Lim, Jang-Seob;Moon, Chae-Joo;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1957-1959
    • /
    • 2000
  • The PD measurement method is very useful to detect insulation degradation. Recently, the HFPD(High Frequency Partial Discharge) measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires in-service diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In this study, simulated transformer is manufactured and HFPD occurred from simulated transformer is measured with broad band antenna and active-line RF measurement system in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages. Also the PD pattern which was measured with EMC analyzer and RF measurement system is compared.

  • PDF

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable (고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구)

  • Song Jae-Yong;Seo Hwang-Dong;Park Dae-Won;Kil Gyung-Suk;Han Moon-Sup;Jang Dong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.

Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance (절연유-절연지에서 이중 임피던스에 의해 부분방전측정)

  • Kim, K.H.;Ryu, H.S.;Sun, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing (분포형 광음향센싱 기반 부분방전 모니터링 기술 연구)

  • Huioon, Kim;Joo-young, Lee;Hyoyoung, Jung;Young Ho, Kim;Myoung Jin, Kim
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.

A Transfer Alignment Considering Measurement Time-Delay and Ship Body Flexure (측정치 시간지연과 선체의 유연성을 고려한 전달정렬 기법)

  • Lim, You-Chol;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.225-233
    • /
    • 2001
  • This paper deals with the transfer alignment problem of SDINS(StrapDown Inertial Navigation System) subjected to roll and pitch motions of the ship. Specifically, to reduce alignment errors induced by measurement time-delay and ship body flexure, an error compensation method is suggested based on delay state augmentation and DCM(Direction Cosine Matrix) partial matching. A linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonlinear measurement equation with respect to its time delay and augmenting the delay state into the conventional linear state equations. And then DCM partial matching is properly combined to reduce effects of a ship's Y axis flexure. The simulation results show that the suggested method is effective enough resulting in considerably less azimuth alignment errors.

  • PDF