• 제목/요약/키워드: partial heating

검색결과 154건 처리시간 0.03초

Effects of partial pressures of various gases on the qualities of long coated conductors fabricated in vacuum

  • Lee, Byoung-Su;Kim, Ho-Sup;Youm, Do-Jun
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.140-140
    • /
    • 2000
  • The effects of partial pressures of various gases on the qualities of coated conductors are studied, where the long samples were fabricated in a vacuum of a large physical vapour deposition system. The various gases such as $0_25,$H_2$,H_20$,$C_n H_m$, and CO come out from the large heating system and gives somewhat complicated effects on the interfacial chemistry at CeO/Ni which Is Important for the epitaxial growth of the film. The results of XRD measurements on the films fabricated in the controlled partial pressures of thoes gases will be presented.

  • PDF

소결조건이 Mn-Zn Ferrites의 전자기적 물성에 미치는 효과 (Effect of Sintering Conditions on the Electromagnetic Properties of Mn-Zn Ferrites)

  • 최윤호;신명승;한승기;한영호
    • 한국세라믹학회지
    • /
    • 제34권6호
    • /
    • pp.561-568
    • /
    • 1997
  • The effects of sintering temperature and oxygen partial pressure on the electromagnetic properties of Mn-Zn ferrites were investigated. The grain increased with increasing temperature. The power loss at 100 kHz was decreased, while the power loss at 500 kHz was increased as the grain size increased with sintering temperature. Sintering with low oxygen partial pressure at 115$0^{\circ}C$ resulted in high density and initial permeability, and decreased the power loss at 100 kHz and 500 kHz. The oxygen partial pressure lower than 10-2 atm. during heating, significantly suppressed the hysteresis loss. However, the oxygen activity did not affect the grain size of sintered cores.

  • PDF

학교 건물에 설치된 지열원 열펌프 시스템의 실사용을 통한 냉난방성능 연구 (Cooling and Heating Performance Under the Actual Operating Condition of a Ground Source Heat Pump System in a School Building)

  • 김의영;정영만;송재도;이재근;김인규;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.586-589
    • /
    • 2009
  • This paper presents the performance of a water-to-refrigerant type ground source heat pump (GSHP) system installed in a school building in Korea. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the input power of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.5 at 60% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 6.5 at 45% partial load condition, while the overall system COP was found to be 5.0.

  • PDF

온돌난방제어 시 시스템저항 변화에 따른 유량 밸런싱에 관한 연구 (A Study for Flow-rate Balancing when the System Resistance Changes in the Control of the Radiant Floor Heating System)

  • 최정민;이규남;류성룡;김광우;여명석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2005
  • The behavior of whole system is affected by a minor change of system in the hydronic radiant floor heating system. Under partial load condition, the change of system resistance causes overflow of supply water. This unexpected effect is the cause of several problems in the heating system. In this study, we find some factors were validated with several computer simulations. After validation of this result, several conceptual solutions are evaluated to prevent overflow.

  • PDF

밑면에서 부분가열을 받는 경사4각형 밀폐공간내의 자연대류 열전달 및 유동특성 (Natural Convective Heat Transfer and Flow Characteristics in Inclined Rectangular Enclosures with Localized Heating from Below)

  • 김상호;정인기;김중엽
    • 대한설비공학회지:설비저널
    • /
    • 제13권3호
    • /
    • pp.148-156
    • /
    • 1984
  • The effect of inclination on the steady, two-dimensional, laminar natural convection in rectangular enclosures with localized heating from below has been investigated numerically. The enclosure was uniformly heated with a partial heat source at the center of the bottom wall and cooled from the upper wall while the other walls were insulated. The governing equations were solved numerically by using the ADI finite difference method with the SOR method. The computations were carrid out with air, Pr =0.733, in the Grashof number range, $1\times10^4\~3\times10^4$, for the inclination of the enclosures was varied from $0^{\circ}\;to\;90^{\circ}$. The effects of Grashof number and aspect ratio on the inclination for the transition of the flow pattern in enclosures were determined. From the results, it was found that the transition angles of the flow in the enclosures were greater in localized heating than in uniform heating from below, and that the inclination was to strongly effect on the heat transfer and the flow pattern within the enclosure.

  • PDF

지역난방 2차측 공급수 온도 제어방안(설정온도 제어, 외기온 보상제어, 외기온 예측제어)에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis on Temperature Control Strategies (Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control) of Secondary Side Hot Water of District Heating System)

  • 조성환;홍성기;이상준
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.137-145
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side of District Heating System (DHS) with different hot water supply temperature control methods are compared. Three methods are Set-point Control, Outdoor Temperature Reset Control and Outdoor Temperature Prediction Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side of the system, the results show that Outdoor Temperature Prediction Control method saves more energy. In general, Outdoor Temperature Prediction Control method lowers the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, Outdoor Temperature Prediction Control method saves about 7.1% in comparison to Outdoor Temperature Reset Control method and about 15.7% in comparison to Set-point Control method. Also, it is found that at when partial load condition, such as daytime, the fluctuation of hot water supply temperature with Set-point Control is more severe than Outdoor Temperature Prediction Control. Therefore, it proves that Outdoor Temperature Prediction Control is more stable even at the partial load conditions.

$(R_{0.8}Ca_{0.2})Ba_2Cu_3O_{7-z}$ (R = Lu 및 Y)의 상 안정도 특성 (Phase Stability of bulk $(R_{0.8}Ca_{0.2})Ba_2Cu_3O_z$ (R = Lu and Y) Compounds)

  • 배수민;이호근
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.25-29
    • /
    • 2009
  • Polycrystalline samples of $(R_{0.8}Ca_{0.2})Ba_2Cu_3O_{7-z}$ (R = Lu and Y) were synthesized by a solid-state reaction route, and the phase stabilities were examined by heating at temperatures between $800^{\circ}C$ and $900^{\circ}C$ in various atmospheres. A comparative analyses of the x-ray diffraction data of the $(Lu_{0.8}Ca_{0.2})Ba_2Cu_3O_{7-z}$ and $(Y_{0.8}Ca_{0.2})Ba_2Cu_3O_{7-z}$ compounds showed that the 123 phase of both compounds is stable under heating in air and $O_2$ of 1 atm. However, contrary to the $(Y_{0.8}Ca_{0.2})Ba_2Cu_3O_{7-z}$ compound, the $(Lu_{0.8}Ca_{0.2})Ba_2Cu_3O_z$ compound was found to become unstable when heated in the low oxygen partial pressure below about 8 % $O_2\;in\;N_2$, Considering the instability of parent $LuBa_2Cu_3O_z$ compound, this result suggests that the phase stability of Lu-based 123 compounds is sensitive to both the composition and the oxygen partial pressure.

  • PDF

Effects of Oxygen Partial Pressure on Oxidation Behavior of CMnSi TRIP Steel in an Oxidation-Reduction Scheme

  • Kim, Seong-Hwan;Huh, Joo-Youl;Kim, Myung-Soo;Kim, Jong-Sang
    • Corrosion Science and Technology
    • /
    • 제16권1호
    • /
    • pp.15-22
    • /
    • 2017
  • An oxidation-reduction scheme is an alternative approach for improving the galvanizability of advanced high-strength steel in the continuous hot-dip galvanizing process. Here, we investigated the effect of oxygen partial pressure ($P_{O_2}$) on the oxidation behavior of a transformation-induced plasticity steel containing 1.5 wt% Si and 1.6 wt% Mn during heating to and holding for 60 s at $700^{\circ}C$ under atmospheres with various $P_{O_2}$ values. Irrespective of $P_{O_2}$, a thin amorphous Si-rich layer of Si-Mn-O was formed underneath the Fe oxide scale (a $Fe_2O_3/Fe_3O_4$ bilayer) in the heating stage. In contrast to Si, Mn tended to segregate at the scale surface as $(Fe,Mn)_2O_3$. The multilayered structure of $(Fe,Mn)_2O_3/Fe_2O_3/Fe_3O_4$/amorphous Si-Mn-O remained even after extended oxidizing at $700^{\circ}C$ for 60 s. $Fe_2O_3$ was the dominantly growing oxide phase in the scale. The enhanced growth rate of $Fe_2O_3$ with increasing $P_{O_2}$ resulted in the formation of more Kirkendall voids in the amorphous Si-rich layer and a less Mn segregation at the scale surface. The mechanisms underlying the absence of FeO and the formation of Kirkendall voids are discussed.

PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석 (The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short)

  • 고석환;주영철;소정훈;황혜미;정영석;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향 (Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature)

  • 박다인;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.