• 제목/요약/키워드: partial heating

검색결과 154건 처리시간 0.023초

국부가열을 이용한 핫스탬핑 공정에서 Tailor Rolled Blank의 스프링백 예측 (Springback Prediction of Tailor Rolled Blank in Hot Stamping Process by Partial Heating)

  • 심규호;김재홍;김병민
    • 소성∙가공
    • /
    • 제25권6호
    • /
    • pp.396-401
    • /
    • 2016
  • Recently, Multi-strength hot stamping process has been widely used to achieve lightweight and crashworthiness in automotive industry. In concept of multi-strength hot stamping process, process design of tailor rolled blank(TRB) in partial heating is difficult because of thickness and temperature variation of blank. In this study, springback prediction of TRB in partial heating process was performed considering its thickness and temperature variation. In partial heating process, TRB was heated up to $900^{\circ}C$ for thicker side and below $Ac_3$ transformation temperature for thinner side, respectively. Johnson-Mehl-Avrami-Kolmogorov(JMAK) equation was applied to calculate austenite fraction according to heating temperature. Calculated austenite fraction was applied to FE-simulation for the prediction of springback. Experiment for partial heating process of TRB was also performed to verify prediction accuracy of FE-simulation coupled with JMAK equation.

중규모에서의 수평대류에 관한 수치모의 (A Numerical Simulation of Horizontal Convection in Mesoscale)

  • 정우식;이화운
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.233-241
    • /
    • 1998
  • This study Is concerned with properties of a thermal convection in a stably stratified Boussinesq fluid caused by partial heating at the lower boundary. For thins purpose, two-dimensional, nonrotating system was employed. U the heating is very strong, convection takes the form of a turbulent plume. Othenuse, remains laminar. If the partial heating at the bottom boundary Is symmetric. the convection takes the form of a trubuient plume. Otherwise remains but beating form Is not so signiacant as to alter the vergence in the lower layer at the center of the partial heating area. The temperature perturbation is characterized by the temperature 'Cross-Over' over the partial heating area. These features are cleared ac- cording to the Increase of temperature difference between the center and side part of the bottom boundary.

  • PDF

일반류가 수평대류에 미치는 영향에 관한 수치연구 (A Numerical Study of a Effect of the Uniform Flow in Horizontal Convection)

  • 이화운;김유근;정우식
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.349-360
    • /
    • 1998
  • Effects of uniform flow on a two-dimensional mesoscale horizontal convection were investigated by using the vorticity and thermodynamic equations. For thins purpose, We simulated properties of a thermal convection m a stably stratified Boussinesq flued caused by partial heating at the center of a lower boundary If we don't consider effects of the uniform flow, the convection takes the form of aidsymmetrlc with respect to the z-alds. But when uniform flow Is strong, velocity field and temperature field consist of a sin91e cell structure which spreads upstream side of the partial heating area. The flow pattern for strong uniform flows takes the form of positive temperatue near the ground and negative temperature perturbation soft over the partial heating area, and downward motion directly over the upwind portion of the partial heating area and upward motion on the downstream side. The downstream edge of the upstream cell Is shifted in the downstream direction with the Increase of uniform flow almost linearly.

  • PDF

Development of a PLD heater for continuous deposition and growth of superconducting layer

  • Jeongtae Kim;Insung Park;Gwantae Kim;Taekyu Kim;Hongsoo Ha
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권2호
    • /
    • pp.14-18
    • /
    • 2023
  • Superconducting layers deposited on the metal substrate using the pulsed laser deposition process (PLD) play a crucial role in exploring new applications of superconducting wires and enhancing the performance of superconducting devices. In order to improve the superconducting property and increase the throughput of superconducting wire fabricated by pulsed laser deposition, high temperature heating device is needed that provides high temperature stability and strong durability in high oxygen partial pressure environments while minimizing performance degradation caused by surface contamination. In this study, new heating device have been developed for PLD process that deposit and growth the superconducting material continuously on substrate using reel-to-reel transportation apparatus. New heating device is designed and fabricated using iron-chromium-aluminum wire and alumina tube as a heating element and sheath materials, respectively. Heating temperature of the heater was reached over 850 ℃ under 700 mTorr of oxygen partial pressure and is kept for 5 hours. The experimental results confirm the effectiveness of the developed heating device system in maintaining a stable and consistent temperature in PLD. These research findings make significant contributions to the exploration of new applications for superconducting materials and the enhancement of superconducting device performance.

Hot Gas Analysis of Circuit Breakers By Combining Partial Characteristic Method with Net Emission Coefficient

  • Park, Sang-Hun;Bae, Chae-Yoon;Jung, Hyun-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권3호
    • /
    • pp.115-121
    • /
    • 2003
  • This paper proposes a radiation model, which considers radiation transport as an important component in hot gas analysis. This radiation model is derived from combining the method of partial characteristics (MPC) with net emission coefficient (NEC), and it covers the drawbacks of existing models. Subsequently, using this proposed model, the arc-flow interaction in an arcing chamber can be efficiently computed. The arc is represented as an energy source term composed of ohmic heating and the radiation transport in the energy conservation equation. Ohmic heating term was computed by the electric field analysis within the conducting plasma region. Radiation transport was calculated by the proposed radiation model. Also, in this paper, radiation models were introduced and applied to the gas circuit breaker (GCB) model. Through simulation results, the efficiency of the proposed model was confirmed.

A techno-economic analysis of partial repowering of a 210 MW coal fired power plant

  • Samanta, Samiran;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제3권3호
    • /
    • pp.167-179
    • /
    • 2015
  • This paper presents a techno-economic analysis of a partial repowering scheme for an existing 210 MW coal fired power plant by integrating a gas turbine and by employing waste heat recovery. In this repowering scheme, one of the four operating coal mills is taken out and a new natural gas fired gas turbine (GT) block is considered to be integrated, whose exhaust is fed to the furnace of the existing boiler. Feedwater heating is proposed through the utilization of waste heat of the boiler exhaust gas. From the thermodynamic analysis it is seen that the proposed repowering scheme helps to increase the plant capacity by about 28% and the overall efficiency by 27%. It also results in 21% reduction in the plant heat rate and 29% reduction in the specific $CO_2$ emissions. The economic analysis reveals that the partial repowering scheme is cost effective resulting in a reduction of the unit cost of electricity (UCOE) by 8.4%. The economic analysis further shows that the UCOE of the repowered plant is lower than that of a new green-field power plant of similar capacity.

실리콘러버 기반의 히터제작에 관한 연구 (A Study on the Fabrication of Heater based on Silicone Rubber)

  • 홍정오;홍재택;최신형
    • 산업과 과학
    • /
    • 제2권2호
    • /
    • pp.9-15
    • /
    • 2023
  • 실리콘러버히터는 플렉시블하기 때문에 평면, 곡면, 입체적인 형태에서도 직접 접착이나 피가열물에 넣어 설치할 수 있다. 현재의 가열방식은 열이 필요하지 않은 영역 또는 위치를 무시하고 피가열물체 전체를 가열하여 필요한 온도로 상승시키기 때문에 일부분만을 부분집중 가열할 수 없었다. 멀티히팅존을 이용하면 피가열물체 전체를 가열하는 것보다는 공정에 따라 열이 필요한 부분만 집중가열하기 때문에 열이 필요한 장소마다 적은 전기용량으로 발열량을 다르게 적용하여 국소 위치별로 빠르게 가열할 수 있고, 열에너지를 줄일 수 있다. 본 연구에서는 열융착이 필요한 영역에서 균일한 온도 또는 온도 차이가 발생하도록 다중 가열영역 구조내의 부분집중 영역에 대한 온도 및 가열 시간을 측정한다. 최적의 전력밀도 범위 결정 및 전기용량을 감소하기 위해 멀티히팅존 구조로 제작된 실리콘러버히터의 안전성을 알아본다. 이와 같이 다중가열방식으로 실리콘러버히터를 제작하면 다중집중 가열기술을 모든 가열공정에 이상적으로 적용할 수 있다.

열병합발전 아파트의 난방조절방식과 온열환경 (Thermal Environment and Heating Regulation System of the Co-Generation Apartment)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제30권3호
    • /
    • pp.131-140
    • /
    • 1992
  • The purpose of this study was to investigate the heating regulation systems and the thermal environment of the Co-Generation apartment house in winter. Personal self-administration and interview method were used in the survey of this study. The respondents were 352 housewives who resided in Mokdong apartement using Co-Generation heating systems. Data was analyzed using SPSS PC+ computer package. The results of this study were summarised as follow; The typical patterns of heating regulation systems were intermittent and partial heating in the living room and bedroom exclusive of kitchen area. The present condition of the thermal environment were relatively warm in winter and Heatng regulation systems were influenced by type of location. Determinants of the thermal sensation and thermal comfort were the type of location of apartment as a architectural factor, clo as a personal factor.

  • PDF

인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter)

  • 조성환;홍성기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.

물-공기 히트펌프 시스템의 부분부하 난방운전 특성 (Performance Characteristics of Water-to-Air Heat Pump under Partial Load Heating Operation)

  • 조용;이남영;김용열;김대근;정응태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.170.1-170.1
    • /
    • 2010
  • Performance of water-to-air heat pump using raw water has been analyzed under part load heating operation in March, 2010. The water source heat pump of 30 RT was installed for 24 hours cooling and heating ventilation, and the gravity inflow water from Daechung dam is used as the heat source. The daily averaged water and air temperatures are $5.7^{\circ}C$ and $9.9^{\circ}C$ respectively, and the heat pump is operated under part load condition for 7.5 hours in 24 hours. The daily averaged heat pump COP calculated with heat transferred from the brine water is 2.49 and the monthly averaged COP is 2.25 in March. Based on the database of the California Energy Commission, the monthly averaged COPs of air source heat pumps installed in U.S.A. are 1.97 in March and 2.03 in April. Therefore it is confirmed again that the performance of the heat pump using raw water is better than that of air source heat pumps.

  • PDF