• Title/Summary/Keyword: partial function

Search Result 1,248, Processing Time 0.025 seconds

Study on Behavior Characteristics of L-Type Flange Bolt Connection for Supporting Structures of Wind Turbines (풍력터빈 지지구조물 L형 플랜지 볼트 접합부의 거동 특성에 관한 연구)

  • Jung, Dae-Jin;Hong, Kwan-Young;Choi, Ik-Chang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.279-286
    • /
    • 2021
  • In this study, we investigated the behavior characteristics of the L-type flange bolt connection, which is used to connect upper and lower flanges having L-type ring sections, by bolts. This connection is mainly used in domestic wind turbine structures, wherein it is a vital component as any imperfection could cause the collapse of the entire structural system. Therefore, understanding the behavior characteristics of the L-type flange bolt connection is imperative. In this study, the connection's response to external force was simulated using finite element (FE) analysis and the FE model was idealized to behave as a single L-type bolt flange. The variation in the bolt tension and the L-type flange stress were analyzed to understand the behavior characteristics of the connection. Moreover, the bolt-load function models proposed by Petersen, Schmidt/Neuper and VDI 2230, theoretically expressing a relation between bolt tension and external force, were compared to evaluate the suitability of the FE analysis and analyze the significant behavior characteristics of the connection. Furthermore, the changes in the bolt-load curve due to the variations in the partial dimensions of the L-type flange bolt connection were analyzed.

Full mouth rehabilitation of a patient with excessive worn dentition by increasing vertical dimension of occlusion: a case report (과도한 치아 마모 환자에서 교합수직고경 증가를 동반한 완전구강회복 증례)

  • Jong Seok Lee;Ji Suk Shim;Jae Jun Ryu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.234-244
    • /
    • 2023
  • Tooth wear refers to the loss of dental hard tissue caused by various physiological and pathological causes, and excessive pathological wear can cause complications such as pathological changes in dimensions, occlusal disharmony, loss of function, and aesthetic problems. The cause of tooth wear can be caused by attrition, abrasion, corrosion and abfraction, and it is known to act in a multifactorial etiology in interocclusal activity. In patients with excessive pathological wear, it is important to determine whether or not the vertical dimension of occlusion is reduced, and complete oral rehabilitation should be achieved with the adaptation of the neuromuscular and temporomandibular joint through accurate diagnosis and analysis. The patient in this case was a 63-year-old male patient, who presented discomfort to cold beverage due to severe tooth wear. After analysis of the patient's vertical dimension of occlusion, a full mouth rehabilitation was performed with increasing vertical dimension of occlusion. The goal of treatment was to improve the occlusal plane with the equal-intensity contact of all teeth, harmonious anterior guidance and immediate disclusion of all posterior contacts. After rehabilitation, the patient was satisfied with function and esthetic appearance.

An Evaluation of the Impact of Ammonium Nitrate Explosion Occurred in Beirut Port (베이루트항에서 발생한 질산암모늄 폭발에 의한 영향 평가)

  • Yong-Kyun Yoon
    • Explosives and Blasting
    • /
    • v.41 no.4
    • /
    • pp.1-8
    • /
    • 2023
  • On August 4, 2020, 2750 tons of ammonium nitrate stored in a storage warehouse at the Port of Beirut exploded. This explosion is said to be the largest ammonium nitrate explosion ever. By applying the TNT equivalency method, TNT equivalent amount corresponding to the explosion energy of 2750 tons of ammonium nitrate was calculated, and it is found to be 856 tons. Overpressure and impulse were calculated in a range up to 3600 m from the blast using the Kingery-Bulmash explosion parameter calculator tool. As the distance from the explosion center increases, the overpressure and impulse decrease exponentially, but the overpressure decreases more significantly, showing that overpressure is more affected by distance than the impact. As a result of applying the damage criteria to evaluate the effects of overpressure and impulse on the structure, the critical distances at which partial collapse, major damage, and minor damage to the structure occur are found to be approximately 500, 800, and 2200 m from the center of the explosion, respectively. The probit function was applied to evaluate the probability of damage to structures and human body. The points where the probability of collapse, major damage, minor damage, and breakage of window-panes to structures are greater than 50% are found to be approximately 500, 810, 2200, and 3200 m, respectively. For people within 200 m from the center of the explosion, the probability of death due to lung damage is more than 99%, and the 50% probability of eardrum rupture is approximately 300 m. The points with a 100% probability of death due to skull rupture and whole body impact due to whole body displacement are evaluated to be 300 and 100 m, respectively.

Application of Back Analysis Technique Based on Direct Search Method to Estimate Tension of Suspension Bridge Hanger Cable (현수교 행어케이블의 장력 추정을 위한 직접탐색법 기반의 역해석 기법의 적용 )

  • Jin-Soo Kim;Jae-Bong Park;Kwang-Rim Park;Dong-Uk Park;Sung-Wan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.120-129
    • /
    • 2023
  • Hanger cable tension is a major response that can determine the integrity and safety of suspension bridges. In general, the vibration method is used to estimate hanger cable tension on operational suspension bridges. It measures natural frequencies from hanger cables and indirectly estimates tension using the geometry conditions of the hanger cables. This study estimated the hanger cable tension of the Palyeong Bridge using a vision-based system. The vision-based system used digital camcorders and tripods considering the convenience and economic efficiency of measurement. Measuring the natural frequencies for high-order modes required for the vibration method is difficult because the hanger cable response measured using the vision-based system is displacement-based. Therefore, this study proposed a back analysis technique for estimating tension using the natural frequencies of low-order modes. Optimization for the back analysis technique was performed by defining the difference between the natural frequencies of hanger cables measured in the field and those calculated using finite element analysis as the objective function. The direct search method that does not require the partial derivatives of the objective function was applied as the optimization method. The reliability and accuracy of the back analysis technique were verified by comparing the tension calculated using the method with that estimated using the vibration method. Tension was accurately estimated using the natural frequencies of low-order modes by applying the back analysis technique.

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Changes of Coagulability after Off-pump CABG: Comparison with On-pump CABG (심폐바이패스 없이 시행하는 관상동맥우회술 후 혈액응고 기늠의 변화: 심폐바이패스하 관상동맥우회술 후 혈액응고 상태와의 비교)

  • 장우익;김기봉;김욱성;정철현;허재학;장지민;이동순;한규섭
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Hemostatic function is regarded to be preserved after an off-pump coronary artery bypass grafting (CABG), compared to conventional CABG, and the preserved hemostatic function may increase thrombotic occlusion of the graft. We studied the changes of hemostatic variables in patients undergoing off-pump CABG, and compared to those of on-pump CABG. We studied the changes of coagulation function in 11 patients who underwent off-pump CABG (group I), and compared them with those of 11 patients who underwent on-pump CABG and Dor procedure (group II). Coagulation status was evaluated by thromboelastography and blood coagulation test preoperatively, postoperative 1$^{st}$ day, 2$^{nd}$ day, 3$^{rd}$ day, and 5$^{th}$ day, respectively. Among the variables measured by thromboelastography (such as r time, k time, $\alpha$ angle, and MA value) and blood coagulation test (such as factor Ⅶ, protein S, protein C, antithrombin III, activated protein C resistance test, plasminogen, D-dimer, prothrombin time, activated partial thromboplastin time, platelet count, hemoglobin, and fibrinogen), there were significant differences in the MA value, $\alpha$ angle, and platelet counts between the two groups. MA values were 140$\pm$72% and 153$\pm$98% in group I, and 87$\pm$27% and 78$\pm$28% in group II, at postoperative 3$^{rd}$ and 5$^{th}$ days, respectively (p<0.05). $\alpha$ angle was 122$\pm$92% in group I and 69$\pm$23% in group II at postoperative 3$^{rd}$ day (p=0.09). Platelet count was 63$\pm$55% in group I and 33$\pm$13% in group II at postoperative 3$^{rd}$ day (p<0.05). Patients who underwent off-pump CABG showed increased coagulability during postoperative periods, compared to those who underwent on-pump CABG. Our data suggest that aggressive perioperative anticoagulation therapy is warranted in patients undergoing off-pump CABG. CABG.

Comparison of Deep Learning Frameworks: About Theano, Tensorflow, and Cognitive Toolkit (딥러닝 프레임워크의 비교: 티아노, 텐서플로, CNTK를 중심으로)

  • Chung, Yeojin;Ahn, SungMahn;Yang, Jiheon;Lee, Jaejoon
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.1-17
    • /
    • 2017
  • The deep learning framework is software designed to help develop deep learning models. Some of its important functions include "automatic differentiation" and "utilization of GPU". The list of popular deep learning framework includes Caffe (BVLC) and Theano (University of Montreal). And recently, Microsoft's deep learning framework, Microsoft Cognitive Toolkit, was released as open-source license, following Google's Tensorflow a year earlier. The early deep learning frameworks have been developed mainly for research at universities. Beginning with the inception of Tensorflow, however, it seems that companies such as Microsoft and Facebook have started to join the competition of framework development. Given the trend, Google and other companies are expected to continue investing in the deep learning framework to bring forward the initiative in the artificial intelligence business. From this point of view, we think it is a good time to compare some of deep learning frameworks. So we compare three deep learning frameworks which can be used as a Python library. Those are Google's Tensorflow, Microsoft's CNTK, and Theano which is sort of a predecessor of the preceding two. The most common and important function of deep learning frameworks is the ability to perform automatic differentiation. Basically all the mathematical expressions of deep learning models can be represented as computational graphs, which consist of nodes and edges. Partial derivatives on each edge of a computational graph can then be obtained. With the partial derivatives, we can let software compute differentiation of any node with respect to any variable by utilizing chain rule of Calculus. First of all, the convenience of coding is in the order of CNTK, Tensorflow, and Theano. The criterion is simply based on the lengths of the codes and the learning curve and the ease of coding are not the main concern. According to the criteria, Theano was the most difficult to implement with, and CNTK and Tensorflow were somewhat easier. With Tensorflow, we need to define weight variables and biases explicitly. The reason that CNTK and Tensorflow are easier to implement with is that those frameworks provide us with more abstraction than Theano. We, however, need to mention that low-level coding is not always bad. It gives us flexibility of coding. With the low-level coding such as in Theano, we can implement and test any new deep learning models or any new search methods that we can think of. The assessment of the execution speed of each framework is that there is not meaningful difference. According to the experiment, execution speeds of Theano and Tensorflow are very similar, although the experiment was limited to a CNN model. In the case of CNTK, the experimental environment was not maintained as the same. The code written in CNTK has to be run in PC environment without GPU where codes execute as much as 50 times slower than with GPU. But we concluded that the difference of execution speed was within the range of variation caused by the different hardware setup. In this study, we compared three types of deep learning framework: Theano, Tensorflow, and CNTK. According to Wikipedia, there are 12 available deep learning frameworks. And 15 different attributes differentiate each framework. Some of the important attributes would include interface language (Python, C ++, Java, etc.) and the availability of libraries on various deep learning models such as CNN, RNN, DBN, and etc. And if a user implements a large scale deep learning model, it will also be important to support multiple GPU or multiple servers. Also, if you are learning the deep learning model, it would also be important if there are enough examples and references.

A Study on Make-up Culture of Korea, China and Japan (한국.중국.일본 여성의 색조대장문화)

  • 박보영;황춘섭
    • Journal of the Korean Society of Costume
    • /
    • v.39
    • /
    • pp.217-237
    • /
    • 1998
  • The present research is to study the make-up culture of Korea and its neighboring countries such as China and Japan during the period from the prehistoric age to the 19th cen-tury. The research was made by documents analysis. The results are summerised as follows : (1) A man has a basic instinct to beautify himself. There was not a significant difference between the make-up behavior of men and women in its primal stage. It was by the start of farming and the division of labor that made the make-up behavior as a feminine culture. The difference of sexual role caused the con-ceptual difference between manly beauty and womanly beauty. It was very natural for women to regard the make-up as the best way for showing their feminine beauty. In Korea, China and Japan, there were vari-ous kinds of primal actions such as tattooing, body-painting, and tooth make-up which were used in the purpose of body protection, incantation, ornament, and so on. Ass their ornamental purpose was becoming more important, these primal actions became the basis of the feminine make-up culture. Nowadays make-up, having mental and emo-tional function, is helpful to increasing self-satisfaction, promoting good personal relation-ship, and attracting attention from the other sex. It also has other functions of showing social status, wealth, age, sex, courage, power, and so on. (2) The representative make-up product used widely in the three countries was Boon (powder) which decides the overall color of face. The key point in the production of Boon was to increase its power of adsorption. The invention of Yunboon (power mixed with lead) solved this major problem of Boon. Yeonji which decides the color of cheek was the mixture of Boon and the powder of Honghwa (a kind of red-colored flower or tree). Mimook (eyebrow pencil) was developed to match up with the various and changing currencies of penciling eyebrows in each nation and times, Yeonji and Joosa (red sand) were used as Jinji (lip stick). The predominant color of Jinji was red. As miscellaneous methods of partial make-up, there were Kon-ji used in a wedding cer-emony in korea, Aek-hwang, Hwa-jeon, Sa-hong, and Myun-yup in China, and Chi-heuk, a peculial method of partial make-up in japan. (3) There were various factors which decided the characteristics of make-up culture usually reflects international atmosphere, the form of government, economic situation, re-ligious and social ideology, aesthetic sense, symbolizing meanings of colors, and so on. The up and down of an influentian country was one of the major factors which decided the characteristics of the make-up culture of its neighboring countries. When a country took a liberal form of government, it had diverse and splendid tendencies in its make-up culture. The better a nation's economic situation is, the more abandant and various its make-up culture is, and sometimes, the more eccentric and decadents it was. In the field of make-up production, the three countries had their own characteristics. But, as a whole, China was the leading nation who spread the culture and products of make-up to Korea and Japan. Though the Chinese make-up culture and products were usually spread to Japan through Korean, there was some evidence of direct exchanges between China and Japan through its dispatches of Kyun-Tang-Sa(Japanese delegation to the Tang Dynasty). While religion had a positive influence on the development of make-up culture by introducing new methods of make-up, Confucianism exercised strict control over the make-up cul-ture. The currencies in arts and changes of esthetic sense introduced new methods and booms to the make-up culture. Literature made people pay increasing attentions to the countenances of women and changed the standards of esthetic sense. We can find out that the social status of woman was also reflected in the make-up culture. As the social status of women became higher, the feminine make-up culture also developed more then ever. As mentioned above, the make-up cultures of the three countries reflected their social values, esthetic senses, and emotional feelings. Through their cultural exchanges, the three countries could develop various make-up products and methods.

  • PDF

Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis (상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석)

  • Park, Jong-Hee;Wang, Yuan-Kun;Lee, Jeong-Jin;Park, Yeon-Hee;Seo, Jae-Min;Kim, Kyoung-A
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.70-79
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the effect of attachments and palatal coverage on stress distribution in maxillary implant overdenture using finite element analysis. Materials and Methods: Four maxillary overdenture 3-D models with four implants placed in the anterior region were fabricated with computer-aided design. 1) Ball-F: Non-splinted ball attachment and full palatal coverage, 2) Ball-P: Non-splinted ball attachment and U-shaped partial palatal coverage, 3) Bar-F: Splinted milled bar attachment and full palatal coverage, 4) Bar-P: Splinted milled bar attachment and U-shaped partial palatal coverage. Stress distribution analysis was performed with ANSYS workbench 14. 100 N vertical load was applied at the right first molar unilaterally and maximum stress was calculated at the implant, peri-implant bone and mucosa. Results: The use of the ball attachment showed lower maximum stress on implant and peri-implant bone than the use of the milled bar attachment. But it showed contrary tendency in the mucosa. Regardless of attachment, full palatal coverage showed lower maximum stress on implant, peri-implant bone and mucosa. Conclusion: Within the limitation of this study, ball attachment improved stress distribution on implant and peri-implant bone rather than milled bar attachment in maxillary implant overdenture. Also, full palatal coverage is more favorable in stress distribution.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.