• Title/Summary/Keyword: partial factor method

Search Result 286, Processing Time 0.041 seconds

A Noel Soft-Switching AC-DC Converter using $L^2SC$

  • Kim C. S.;Lee H. W.;Suh K. Y.;Kim H. D.;Kim K. T.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.271-275
    • /
    • 2001
  • In this paper, proposes a novel AC-DC converter of high power factor and high efficiency by partial resonant method. The input current waveform in proposed circuit is got to be a discontinuous sinusoidal form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Thereupon, the input power factor is nearly unity and the control circuit is simple. Also the switching devices in a proposed circuit are operated with soft switching by the partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. The partial resonant circuit makes use of a inductor using step up and $L^2SC$ (Loss-Less Snubber Condenser). The switching control technique of the converter is simplified for switches to drive in constant duty cycle. Some simulative results and experimental results are included to confirm the validity of the analytical results.

  • PDF

SINGULAR AND DUAL SINGULAR FUNCTIONS FOR PARTIAL DIFFERENTIAL EQUATION WITH AN INPUT FUNCTION IN H1(Ω)

  • Woo, Gyungsoo;Kim, Seokchan
    • East Asian mathematical journal
    • /
    • v.38 no.5
    • /
    • pp.603-610
    • /
    • 2022
  • In [6, 7] they introduced a new finite element method for accurate numerical solutions of Poisson equations with corner singularities. They consider the Poisson equations with homogeneous boundary conditions, compute the finite element solutions using standard FEM and use the extraction formula to compute the stress intensity factor(s), then they posed new PDE with a regular solution by imposing the nonhomogeneous boundary condition using the computed stress intensity factor(s), which converges with optimal speed. From the solution they could get an accurate solution just by adding the singular part. They considered a partial differential equation with the input function f ∈ L2(Ω). In this paper we consider a PDE with the input function f ∈ H1(Ω) and find the corresponding singular and dual singular functions. We also induce the corresponding extraction formula which are the basic element for the approach.

High Power Factor and High Efficiency DC-DC Converter using Single-Pulse Soft-Switching (단일 펄스 소프트 스위칭을 이용한 고역률 고효율 DC-DC 컨버터)

  • Jung, S.H.;Kwon, S.K.;Suh, K.Y.;Lee, H.W.;Gac, D.K.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1148-1150
    • /
    • 2003
  • Power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. However, the switches of converter are subjected to high switching power losses and switching stresses. As a result of those, the power system brings on a low efficiency. To improved these, a large number of soft switching topologies included a resonant circuit has been prosed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose a high power factor and high efficiency DC-DC converter using single-pulse soft switching by partial resonant switching node. The switching devices in a prosed circuit are operated with soft switching by the partial resonant method, that is, Partial Resonant Switch Mode Power Converter. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. Also the proposed converter is deemed the most suitable for high power applications where the power switching devices are used. Some simulative results on computer results are included to confirm the validity of the analytical results.

  • PDF

A performance-based design method for chloride-induced cover cracking of RC structures

  • Yang, Dong-Hui;Yi, Ting-Hua;Li, Hong-Nan
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.573-582
    • /
    • 2017
  • Chloride-induced cover cracking will aggravate the performance deterioration for RC structures under the chlorideladen environment, which may endanger the safety of structures and occupants. Traditional design method cannot ensure that a definite performance is satisfied. To overcome the defects, a study on the performance-based design method was carried out in this paper. Firstly, the limit state functions were established for the corrosion initiation and cover cracking. Thereafter, the uncertainty analysis was performed to study the effects of random factors on the time-dependent performances. Partial factor formulae were deduced through the first-order reliability method for performance verification. Finally, an illustrative example was presented and the sensitivity of cover depth to other parameters was carried out. It is found that the uncertainties of the random variables have great effects on the required cover depth. It is demonstrated that the performance-based design method can ensure that the target performance can be satisfied and support to formulate a rational maintenance and repair strategy for RC structures under the chloride environment.

PRICING CONVERTIBLE BONDS WITH KNOWN INTEREST RATE

  • Kim, Jong Heon
    • Korean Journal of Mathematics
    • /
    • v.14 no.2
    • /
    • pp.185-202
    • /
    • 2006
  • In this paper, using the Black-Scholes analysis, we will derive the partial differential equation of convertible bonds with both non-stochastic and stochastic interest rate. We also find numerical solutions of convertible bonds equation with known interest rate using the finite element method.

  • PDF

The Utility Interaction type PV system by using partial resonant system (부분공진기법을 이용한 연계형 태양광발전시스템)

  • 고강훈;이현우;김영철;최광주
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.290-295
    • /
    • 1999
  • This paper describes Trans-less type utility interactive system that is combined with buck/boost chopper applying partial resonant method, which remove Trans, and high efficient PWM inverter. Therefore, it is possible to make it lightweight, to cut down the cost, and to improve its reliability. What the merits of this system are that we con transmit arbitrary power to load and utility regardless of generating voltage magnitude and we can always obtain high factor controlling by equal phase signal with utility.

  • PDF

Clinical Results of Partial Zona Dissection for Infertility (불임환자에 있어서 Partial Zona Dissection(PZD) 의한 임상적인 결과)

  • Park, Sung-Eun;Choi, Dong-Hee;Rho, Hwan-Cheol;Ko, Jung-Jae;Park, Jong-Young;Cha, Kwang-Yul
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.20 no.1
    • /
    • pp.45-51
    • /
    • 1993
  • Micromanipulation procedures have been used to improve fertilization rates in patients with male factor or with unexplained infertility. Partial zona disseetion(PZD), a method using mechanical force to open the zona pellucida increase the chances of fertilization. The purpose of this study is to increase rates of fertilization and pregnacy in the ART program by using PZD. The influence of PZD on the fertilization rate was investigated in 57 couples with semen defects, antisperm antibodies(ASA), or unknown factors. PZD directly performed in 35 couples with a history of fertilization failure in previous cycle (Group 1), and PZD applied in 22 couples with the failure of initial fertilization in the same cycle (Group 2). The fertilization rates of the male facor, ASA positive factor and unknown factor in Group 1 were 37.6%, 20.0% and 59.2%, respectively. The rates of fertilization of male factor, ASA positive factor and unknown factor in Group 2 were 34.8%, 20.0% and 26.5%, respectively. The incidences of polyspermy in Group 1 and Group 2 were 5.9% and 9.0%, respectively. Among 35 patients of Group 1, one patient was pregnant and successfully delivered, whereas 1 of 22 patients of Group 2 became pregnant, but aborted at 7 weeks.

  • PDF

A Study of New Technical Standards for Slope Stability in Port Structures (항만구조물의 사면안정 신 설계기준 연구)

  • Yoon, Gil-Lim;Yoon, Yeo-Won;Kim, Hong-Yeon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2009
  • Technical design codes of slope stability for port structures were studied by comparing local Korean code with international codes; Japanese, EC and China codes. Three international design codes are based on limit state design method. Although Chinese code was based on the modified Fellenius method in slope stability analyses, it is currently changing to the simplified Bishop method. In Eurocode, the Morgenstern & Price method or the Bishop method is recommended. In Japanese code, however, the modified Fellenius method is preferentially recommended, but the simplified Bishop method could be alternatively used in case of thick sandy ground conditions. As for design parameter determination, Eurocode has stipulated comprehensive partial factors and partial material factors, however Japanese code has clarified empirical partial material factors for each port structure. Chinese code, the minimum ranges of the comprehensive partial factors are stipulated, and the use of the strength index by specific tests is concretely clarified with the safety condition. Case study of slope stability analyses showed the safety factors were higher in order of Chinese, Japanese and Eurocode, respectively.

Analysis of Probabilities of Failure and Partial Safety Factors of Armor Units on Tranding and Coastal Harbors (무역항 및 연안항 피복재의 파괴확률과 부분안전계수 해석)

  • Lee, Cheol-Eung;Park, Dong-Heon
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.157-165
    • /
    • 2008
  • Level II AFDA and Level III MCS reliability models are applied to analyze the stability of armor units on trading and coastal harbors in Korea. Hudson's formula and Van der Meer's formula are used in this reliability analysis. Also, probability density functions of reliability index and probability of failure are derived by the additional analysis. In addition, the partial safety factors of all harbors related to armor units can be straightforwardly evaluated by the inverse-reliability method. The upper and lower limits and average level of partial safety factors can be statistically investigated with the results of all cases applied in this paper. Therefore, it may be possible to design armor units of new breakwaters including the uncertainty of random variable and target level by using the present results.

  • PDF

A New Partial Resonant Switching $3\phi$ Boost Converter with High Efficiency Using Lossless Snubber (새로운 무손실 스너버를 이용한 부분공진형 고효율 $3\phi$ AC-DC 부스터 컨버터)

  • 전종함;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.9
    • /
    • pp.118-125
    • /
    • 1997
  • This paper proposed a new partial resonant 3.PHI. AC-DC boost converter of high efficiency using lossless snubber. The proposed converter, DCM (Discontinuous Current Mode) has a merit of simple controlled circuit because the input current control discontinuously. But turned off switching loss and stress of the switching device increase when the switch turned off at the peak of current. Therefore, the paper improves efficiency by adopting the PRS$^{2}$(Partial Resonant Soft Switching) in 3.PHI. AC-DC boost converter and makes the unity power factor. The PRS$^{2}$ is reduced a current/voltage stresses of switching devices. Also, a DCMPRS$^{2}$M(Discontinuous Conduction Mode Partial Resonant Soft Switching Method) appear the current and voltage equation of this circuit. The paepr examine in a 3.PHI. AC-DC boost converter and show the result of that.

  • PDF