• 제목/요약/키워드: partial factor method

검색결과 286건 처리시간 0.037초

Prediction on the Chiral Behaviors of Drugs with Amine Moiety on the Chiral Cellobiohydrolase Stationary Phase Using a Partial Least Square Method

  • Choi, Sun-Ok;Lee, Seok-Ho;Park Choo , Hea-Young
    • Archives of Pharmacal Research
    • /
    • 제27권10호
    • /
    • pp.1009-1015
    • /
    • 2004
  • Quantitative Structure-Resolution Relationship (QSRR) using the Comparative Molecular Field Analysis (CoMFA) software was applied to predict the chromatographic behaviors of chiral drugs with an amine moiety on the chiral cellobiohydrolase (CBH) columns. As a result of the Quantitative CoMFA-Resolution Relationship study, using the partial least square method, prediction of the behavior of drugs with amine moiety upon chiral separation became possible from their three dimensional molecular structures. When a mixed mobile phase of 10 mM aqueous phosphate buffer (pH 7.0) - isopropanol (95 : 5) was employed, the best Quantitative CoMFA-Resolution Relationship, derived from the study, provided a cross-validated $q^2$ = 0.933, a normal $r^2$ = 0.995, while the best Quantitative CoMFA-Separation Factor Relationship, also derived from the study, yielded a cross-validated $q^2$ = 0.939, a normal $r^2$ = 0.991. When all of these results are considered, this QSRR-CoMFA analysis appears to be a very useful tool for the preliminary prediction on the chromatographic behaviors of drugs with an amine moiety inside chiral CBH columns.

간이 스위칭법에 의한 단상 역률개선형 컨버터 (The Single Phase Converter of Power Factor Collection Type with Simple Switching Method)

  • 문경희;고강훈;김은수;곽동걸;조판제;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.323-326
    • /
    • 1999
  • For decrease the harmonic current components of the power source, a first method is insert the choke coil that used the choke input type rectifier, the booster chopper circuit and buck chopper circuit. And the several method are studying like as the PWM(Pulse Width Modulation) converter and the active filter type which is used the high frequency switching and the sinusoidal wave formed input current. In this type, there are many problem as a low efficiency, increased the noise, the high leakage current and cost up by the high frequency switching. For improve this problems, the partial resonan method is used on the booster inducter and lossles snubber condenser. This method decreased the distortion factor has lower harmonic components than the hard switching and there is no switching loss by the ZCS(Zero Current Switching) at switch turn-on and the ZVS(Zero Voltage Swithcing) at switch turn-off

  • PDF

5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구 (Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly)

  • 이강희;윤경호;송기남
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

절연형 고효율 PFC AC-DC 컨버터에 관한 연구 (A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation)

  • 곽동걸;김상훈
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

Sensitivity Analysis by Parametric Study of Load Factor for a Concrete Box Girder Railway Bridge Using Limit State Design

  • Yeo, Inho;Sim, Hyung-Bo;Kim, Daehwan;Kim, Yonghan
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.5-9
    • /
    • 2015
  • Reliability based limit state design method is replacing traditional deterministic designs such as allowable stress design and/or ultimate strength design methods in world trends. European design code(Eurocode) has adopted limit state design, and Korea road bridge design standard has also recently been transferred to limit state design method. In this trend, Korea railroad design standard is also preparing for adopting the same design concept. While safety factors are determined empirically in traditional design, load combinations as well as load factors are determined by solving limit state equations. General partial safety factors are evaluated by using AFORM(Advanced First Order Reliability Method) in the reliability based limit state design method. In this study sensitivity analysis is carried out for a dead load factor and a live load factor. Relative precisions of the dead load and the live load factors are discussed prior to the AFORM analysis. Furthermore the sectional forces of design and the material quantities required by two different design methods are compared for a PSC box girder railway bridge.

Electrical Parameter Extraction of High Performance Package Using PEEC Method

  • Pu, Bo;Lee, Jung-Sang;Nah, Wan-Soo
    • Journal of electromagnetic engineering and science
    • /
    • 제11권1호
    • /
    • pp.62-69
    • /
    • 2011
  • This paper proposes a novel electrical characterization approach for a high-performance package system using an improved Partial Element Equivalent Circuit (PEEC). As the effect of interconnects becomes a pivotal factor for the performance of high-speed electronic systems, there is a great demand for an accurate equivalent model for interconnects. In particular, an equivalent model of interconnects is established in this paper for the Fine-Pitch Ball Grid Array (FBGA) package using the improved PEEC method. Based on the equivalent model, electrical characteristics are analyzed; furthermore, these are verified through the measurement results of a Vector Network Analyzer (VNA).

부분공진기법을 이용한 태양광발전 제어시스템 (The Photovoltaic generation control system using partial resonant method)

  • 고강훈;이현우;김영철;최광주
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.16-22
    • /
    • 2000
  • 본 논문은 트렌스포머를 제거하고 부분공짚 스위칭 기법올 적용한 승.강압초퍼와 고효율의 PWM 인버터를 결합한 트렌스포머리스형 계통연계 시스템을 구성하게 되므로 소형경량화가 가능하며, 비용저지감과 신뢰성 향상을 도모할 수 있다. 이러한 시스템의 장점으로서는 태양잔지의 발전전압의 크기에 관계없이 임의의 전력올 부하와 계통에 송전할 수 있으며, 계통과 동상의 신호로 제어함으로서 상 고역률올 얻을 수 있다.

  • PDF

Reliability-based assessment of damaged concrete buildings

  • Sakka, Zafer I.;Assakkaf, Ibrahim A.;Qazweeni, Jamal S.
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.751-760
    • /
    • 2018
  • Damages in concrete structures due to aging and other factors could be a serious and immense matter. Making the best selection of the most viable and practical repairing and strengthening techniques are relatively difficult tasks using traditional methods of structural analyses. This is due to the fact that the traditional methods used for assessing aging structure are not fully capable when considering the randomness in strength, loads and cost. This paper presents a reliability-based methodology for assessing reinforced concrete members. The methodology of this study is based on probabilistic analysis, using statistics of the random variables in the performance function equations. Principles of reliability updating are used in the assessment process, as new information is taken into account and combined with prior probabilistic models. The methodology can result in a reliability index ${\beta}$ that can be used to assess the structural component by comparing its value with a standard value. In addition, these methods result in partial safety factor values that can be used for the purpose of strengthening the R/C elements of the existing structure. Calculations and computations of the reliability indices and the partial safety factors values are conducted using the First-order Reliability Method and Monte Carlo simulation.

p-수렴 부분층별모델에 의한 일변균열판의 패치재료 및 기하형상에 따른 응력확대계수 (Stress Intensity Factor of Single Edge Cracked Plates Considering Materials and Geometry of Patch by p-Convergent Partial Layerwise Model)

  • 안현지;안재석;우광성
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.191-198
    • /
    • 2010
  • 이 연구에서는 접착패치보강의 서로 다른 형태 즉, 패치와 접착제의 재료, 크기, 두께 뿐만 아니라 일면보강 또는 양면보강에 따른 일변균열판의 응력감소에 대한 연구가 수행되었다. 수치해석 도구로는 p-수렴 부분층별 모델이 사용되었다. 이 모델의 면내 변위는 구간별 연속인 선형변화로 가정하였고, 두께방향으로의 면외 변위는 일정한 상수로 가정하여 적용하였다. 변위장의 정의는 적분형 르장드르 다항식을 적용하였고, 수치적분은 별도의 외삽법 없이 각 층별의 절점에서 발생하는 적분값을 바로 얻을 수 있는 가우스-로바토 적분법을 사용 하였다. 또, 에너지 방출률법을 사용하여 응력확대계수를 산출하였다. 수치예제를 통해 제안된 모델의 정확도는 물론이고 접착패치 보강형태에 따라 변화되는 무차원 응력확대계수와 처짐의 항으로 응력감소 효과를 분석하였다.

청소년의 사회적 지지가 공격성에 미치는 영향: 그릿의 매개효과 (Effects of Social Support on Aggression in Adolescents: The Mediating Role of Grit)

  • 신명옥;방해순
    • 산업융합연구
    • /
    • 제20권10호
    • /
    • pp.147-156
    • /
    • 2022
  • 본 논문의 연구목적은 청소년의 사회적 지지가 공격성에 미치는 영향과 그 관계에서 그릿의 매개효과를 검증하는데 있다. 이를 위해 2018 아동·청소년 패널(KCYPS)조사 데이터를 사용하였으며, 조사 대상자는 중학교 1학년 2,590명을 선정하여 분석을 진행하였다. 분석 방법은 Baron & Kenny의 회귀분석과 Sobel Test를 실시하였다. 주요 분석결과 첫째, 청소년의 사회적 지지의 하위요인인 부모지지가 공격성에 미치는 영향에서 그릿이 부분매개 효과가 있는 것으로 나타났다. 둘째, 청소년의 사회적 지지의 하위요인인 친구지지가 공격성에 미치는 영향에서 그릿이 부분매개 효과가 있는 것으로 나타났다. 셋째, 청소년의 사회적 지지의 하위요인인 교사지지가 공격성에 미치는 영향에서 그릿이 부분매개 효과가 있는 것으로 나타났다. 이상의 연구결과를 토대로 청소년의 공격성을 낮추고 그릿을 향상시킬 수 있는 다양한 프로그램 개발과 정책적 대안을 제시하였다.