• Title/Summary/Keyword: parameter conversion

Search Result 238, Processing Time 0.022 seconds

SI Engine Closed-loop Spark Advance Control Using Cylinder Pressure (실린더 압력을 이용한 SI엔진의 페루프 점화시기 제어에 관한 연구)

  • Park, Seung-Beom;Yun, Pal-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2361-2370
    • /
    • 2000
  • The introduction of inexpensive cylinder pressure sensors provides new opportunities for precise engine control. This paper presents a control strategy of spark advance based upon cylinder pressure of spark ignition engines. A location of peak pressure(LPP) is the major parameter for controlling the spark timing, and also the UP is estimated, using a multi-layer feedforward neural network, which needs only five pressure sensor output voltage samples at -40˚, -20˚, 0˚, 20˚, 40˚ after top dead center. The neural network plays an important role in mitigating the A/D conversion load of an electronic engine controller by increasing the sampling interval from 10 crank angle(CA) to 20˚ CA. A proposed control algorithm does not need a sensor calibration and pegging(bias calculation) procedure because the neural network estimates the UP from the raw sensor output voltage. The estimated LPP can be regarded as a good index for combustion phasing, and can also be used as an MBT control parameter. The feasibility of this methodology is closely examined through steady and transient engine operations to control individual cylinder spark advance. The experimental results have revealed a favorable agreement of individual cylinder optimal combustion phasing.

Determination of Derived Release Limits for a CANDU Nuclear Power Plant (CANDU형 원전에서의 유도방출한도 결정)

  • Kim, Kyo-Youn;Hwang, Hae-Ryong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.23-35
    • /
    • 1994
  • A computer code DRL was developed to calculate the derived release limits at CANDU type nuclear power plants. The derived release limits resulting from DRL code is to set guidelines for the release of radionuclides in airborne and water-borne effuents during normal operations of a CANDU type nuclear power plant. The DRL code generally follows the methodology Prescribed in the CSA standard N288.1-M87 and uses the Parameter values recommended in the same standards. The DRL code was used to calculate a set of preliminary derived release limits for the Wolsong NPP.

  • PDF

Maximizing Network Utilization in IEEE 802.21 Assisted Vertical Handover over Wireless Heterogeneous Networks

  • Pandey, Dinesh;Kim, Beom Hun;Gang, Hui-Seon;Kwon, Goo-Rak;Pyun, Jae-Young
    • Journal of Information Processing Systems
    • /
    • v.14 no.3
    • /
    • pp.771-789
    • /
    • 2018
  • In heterogeneous wireless networks supporting multi-access services, selecting the best network from among the possible heterogeneous connections and providing seamless service during handover for a higher Quality of Services (QoSs) is a big challenge. Thus, we need an intelligent vertical handover (VHO) decision using suitable network parameters. In the conventional VHOs, various network parameters (i.e., signal strength, bandwidth, dropping probability, monetary cost of service, and power consumption) have been used to measure network status and select the preferred network. Because of various parameter features defined in each wireless/mobile network, the parameter conversion between different networks is required for a handover decision. Therefore, the handover process is highly complex and the selection of parameters is always an issue. In this paper, we present how to maximize network utilization as more than one target network exists during VHO. Also, we show how network parameters can be imbedded into IEEE 802.21-based signaling procedures to provide seamless connectivity during a handover. The network simulation showed that QoS-effective target network selection could be achieved by choosing the suitable parameters from Layers 1 and 2 in each candidate network.

A Study on the Errors for the Improved Version of the Virtual Transmission-Line Model (개선된 가상의 전송선로 모델의 오차 연구)

  • 조유선;김세윤;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.971-981
    • /
    • 2002
  • An open-ended coaxial probe method has been considered as one of effective tools for measuring electrical properties of its contacted material without shaping and fitting. The measured reflection coefficient at the probe's end is able to convert into the corresponding complex permittivity by employing the improved version of virtual transmission-line model Presented by our lab already. But the error of complex permittivity converted by equivalent model increases as the operating frequency ascends high. The errors of complex permittivity in the open-ended coaxial probe can be yielded compositively by the imperfect contact or probe, manufacture error of probe and complex permittivity error of reference material etc. Therefore it is necessary to limit the problem to identify the error causes in high frequency. In this paper, the errors which are resulted from the measurement of reflection coefficient are removed by using the FDTD(Finite-Difference Time-Domain) method, the error causes are limited the conversion model problem. And the error study of the improved conversion model is performed from several viewpoints. At first, the local minimum of parameter to be calculated by the iteration method in the conversion model is checked. At second, the modeling of the equivalent model is checked in the frequency range. From this study, we know the valid range of the improved conversion model.

Effects of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter in ducks under scorching heat wave (폭염 하에서 음수 내 비타민 C와 트리메칠글리신 공급이 오리의 혈액 매개변수 및 생산성에 미치는 효과)

  • Kang, H.K.;Park, B.S.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.411-420
    • /
    • 2016
  • The objective of this study was to determine the effect of drinking water containing trimethyl glycine or ascorbic acid on growth performance and blood parameter profiles of duck exposed to scorching heat stress. A total of 480 ducks were randomly assigned to the following eight experiment groups for 42 days : control group C with general water, treatment group 1 (T1) with drinking water containing 100 ppm ascorbic acid, treatment group 2 (T2) with drinking water containing 200 ppm ascorbic acid, treatment group 3 (T3) with drinking water containing 300 ppm ascorbic acid, treatment group 4 (T4) with drinking water containing 400 ppm trimethyl glycine, treatment group 5 (T5) with drinking water containing 800 ppm trimethyl glycine, treatment group 6 (T6) with drinking water containing 1,200 ppm trimethyl glycine, treatment group 7 (T7) with electrolytes of KCl (0.5%) + $NaHCO_3$ (1.0%)+NaCl (0.5%). Our results revealed that the body weights and feed intakes of treatment groups, especially T3 and T6, were increased compared to the control group, where as the feed conversion ratios of treatment groups were decreased (p<0.05). Blood levels of total cholesterol, triglyceride, LDL-C, glucose, AST, ALT and pH in treatment groups were lower compared to those in the control group (p<0.05). Blood levels of red blood cell, platelets profiles, electrolyte and gas in treatment groups were higher compared to those of the control group (p<0.05).

A Study on the World Geodetic System Transformation of Cadastral Record Using by Three parameters (3변수를 이용한 지적공부의 세계측지계 변환 연구)

  • Jung, Wan-Suk;Kang, Sang-Gu
    • Journal of Cadastre & Land InformatiX
    • /
    • v.44 no.2
    • /
    • pp.139-153
    • /
    • 2014
  • The world geodetic system transformation of cadastral record have to minimize differences of boundary and area being in cadastral record according to transformation for that is direct connected with the land owner and property protection. However it is very difficult to accurately maintain the before and after transformation because coordinate transformation is generally using a mathematical conversion formula. At present, Helmert model by using 4-parameter is official coordinate transformation model for Cadastral Resurvey Project but scale factor is most sensitive to changes of area and relative position in the same parcel. In this study, it was proposed 3-parameter method using by scale factor fixing through the application of a Helmert in order to avoid changing the area difference and keeping the error within the tolerance range of the boundary which is related to the boundary point coordinate region.

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Analysis and Control Parameter Estimation of a Tubular Linear Motor with Halbach and Radial Magnet Array

  • Jang Seok-Myeong;Choi Jang-Young;Cho Han-Wook;Lee Sung-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.154-161
    • /
    • 2005
  • In the machine tool industry, direct drive linear motor technology is an interesting means to achieve high acceleration, and to increase reliability. This paper analyzes and compares the characteristics of a tubular linear motor with Halbach and radial magnet array, respectively. First, the governing equations are established analytically in terms of the magnetic vector potential and two dimensional cylindrical coordinate systems. Then, we derive magnetic field solutions due to the PMs and the currents. Motor thrust, flux linkage and back emf are also derived. The results are shown to be in good conformity with those obtained from the commonly used finite element method. Finally, control parameters are obtained from analytical solutions.

PROCESS OPTIMIZATION OF METHANE REFORMING IN ARC JET (아크젯 플라즈마에서의 메탄개질의 최적화)

  • Hwang, Na-Kyung;Lee, Dae-Hoon;Song, Young-Hoon
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.266-271
    • /
    • 2006
  • Characteristic of partial oxidation of methane using arc-jet plasma by AC power is investigated. Arc-jet reactor used in this work is slightly modified from typical arc jet reactor so that it can make and sustain stable state of plasma. Methane conversion, selectivity of chemicals such as hydrogen and hydrocarbon materials in the product are analyzed. Parametric approach on the performance of the reactor or detail on the partial oxidation process is carried with $O_2/C$ ratio as parameter. In addition to the results, SED and arc length is changed to understand the effect of current-voltage correlation on the reforming performance and relative role of thermal process.

  • PDF

A Study on Experimental Method of Impulse turbine for OWC-type Wave Energy Conversion (파력발전용 임펄스터빈의 모형시험 기법연구)

  • LEE YOUNG-YEON;HONG SEOK-WON;HYUN BEOM-SOO
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.268-273
    • /
    • 2004
  • A study on experimental method of the model test for the impulse turbine is carried out. the wave simulator is used to reproduce the real wave condition. It controls two parameter correspond to wave height and wave frequency. The optimum design which is reported by T. Setoguchi is manufactured and tested for the validation of our test facilities. The comparison of model test show that our facilities produce little bit higher efficiency at maximum efficiency point. To increase the efficiency of turbine, the new rotor with negative tip clearance is designed and being tested.

  • PDF