• 제목/요약/키워드: parameter conversion

검색결과 239건 처리시간 0.027초

고음질을 갖는 음색변경에 관한 연구 (A Study on the Voice Conversion Algorithm with High Quality)

  • 박형빈;배명진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 제13회 신호처리 합동 학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2000
  • In the generally a voice conversion has used VQ(Vector Quantization) for partitioning the spectral feature and has performed by adding an appropriate offset vector to the source speaker's spectral vector. But there is not represented the target speaker's various characteristics because of discrete characteristics of transformed parameter. In this paper, these problems are solved by using the LMR(Linear Multivariate Regression) instead of the mapping codebook which is determined to the relationship of source and target speaker vocal tract characteristics. Also we propose the method for solved the discontinuity which is caused by applying to time aligned parameters using Dynamic Time Warping the time or pitch-scale modified speech. In our proposed algorithm for overcoming the transitional discontinuities, first of all, we don't change time or pitch scale and by using the LMR change a speaker's vocal tract characteristics in speech with non-modified time or pitch. Compared to existed methods based on VQ and LMR, we have much better voice quality in the result of the proposed algorithm.

  • PDF

낮은 차원의 벡터 변환을 통한 음성 변환 (Voice conversion using low dimensional vector mapping)

  • 이기승;도원;윤대희
    • 전자공학회논문지S
    • /
    • 제35S권4호
    • /
    • pp.118-127
    • /
    • 1998
  • In this paper, we propose a voice personality transformation method which makes one person's voice sound like another person's voice. In order to transform the voice personality, vocal tract transfer function is used as a transformation parameter. Comparing with previous methods, the proposed method can obtain high-quality transformed speech with low computational complexity. Conversion between the vocal tract transfer functions is implemented by a linear mapping based on soft clustering. In this process, mean LPC cepstrum coefficients and mean removed LPC cepstrum modeled by the low dimensional vector are used as transformation parameters. To evaluate the performance of the proposed method, mapping rules are generated from 61 Korean words uttered by two male and one female speakers. These rules are then applied to 9 sentences uttered by the same persons, and objective evaluation and subjective listening tests for the transformed speech are performed.

  • PDF

Analytic equation to energy conversion between electromagnetically coupled superconducting and copper coils

  • An, Soobin;Choi, Kibum;Bang, Jeseok;Bong, Uijong;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권1호
    • /
    • pp.36-39
    • /
    • 2019
  • This paper presents an analytic method to calculate energy conversion between electromagnetically coupled high-temperature superconducting and copper coils. The energy transfer from one coil to the other is commonly observed during quench of a no-insulation (NI) high temperature superconductor (HTS) magnet. Proper understanding of this phenomenon is particularly important to protect an NI HTS magnet, especially to avoid any potential mechanical damages. In this paper, analytic equations are obtained to estimate the energy transfer between the NI and copper coils. The well-known lumped-parameter circuit model is adopted provided that key parameters of the coils are given.

물리 기반의 염료 감응형 태양전지 등가회로 모델링 및 성능 분석 (Physical-based Dye-sensitized Solar Cell Equivalent Circuit Modeling and Performance Analysis)

  • 이운복;송준혁;최휘준;구본용;이종환
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.67-72
    • /
    • 2023
  • In this paper, a dye-sensitized solar cell (DSSC), one of the representative third-generation solar cells with eco-friendly materials and processes compared to other solar cells, was modeled using MATLAB/Simulink. The simulation was conducted by designating values of series resistance, parallel resistance, light absorption coefficient, and thin film electrode thickness, which are directly related to the efficiency of dye-sensitized solar cells, as arbitrary experimental values. In order to analyze the performance of dye-sensitized solar cells, the optimal value among each parameter experimental value related to efficiency was found using formulas for fill factor (FF) and conversion efficiency.

  • PDF

자기동조 적응제어를 이용한 여자제어기 설계에 관한 연구 (A Study on the Design of Excitation Controller using Self Tuning Adaptive Control)

  • 유현호;이상근;김준현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.375-378
    • /
    • 1991
  • This paper presents a design method of synchronous generator excitation controller using self-tuning PID algorithm. Controller parameter is determined by using adaptive control theory in order to maintain optimal operation of generator under the various operating conditions. To determine the optimal parameter of controller. minimum variance algorithm using the recursive leastsquare(RLS) indentification method is adopted and the difference between the speed deviation with weighted factor and voltage deviation is used as the input signal of adaptive controller, which provides good damping and conversion characteristics. The results tested on a single machine infinite bus system verify that the proposed controller has better dynamic performances than conventional controller.

  • PDF

3상 2레벨 계통연계형 태양광 인버터의 강인제어 (Robust Control of a Grid Connected Three-Phase Two-Level Photovoltaic Inverter)

  • 안경필;이영일
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.538-548
    • /
    • 2014
  • This study provides a robust control of a grid-connected three-phase two-level photo voltaic inverter. The introduced control method uses the cascade control strategy to regulate AC-side current and DC-link voltage. A robust controller with integration action is used for the inner-loop AC-side current control, which maximizes the convergence rate using a linear matrix inequality-based optimization design method and eliminates the offset error. The robust controller design method considers the parameter uncertainty set to accommodate parameter mismatch and un-modeled components in the inverter model. An outer-loop proportional-integral controller is used to regulate DC-link voltage with linearization of DC/AC relation. The proposed control strategy is applied to a grid-connected 100 kW photo voltaic inverter.

Identification of the Relationship between Operating Conditions and Polymer Qualities in a Continuous Polymerization Reactor

  • Jeong, Boong-Goon;Yoo, Kee-Youn;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.501-506
    • /
    • 1998
  • A mathematical model is developed to describe the relationship between the manipulated variables (e.g. jacket inlet temperature and feed flow rate) and the important qualities (e.g conversion and weight average molecular weight (Mw)) in a continuous polymerization reactor. The subspace-based identification method for Wiener model is used to retrieve from the discrete sample data the accurate information about both the structure and initial parameter estimates for iterative parameter optimization methods. The comparison of the output of the identified Wiener model with the outputs of a non-linear plant model shows a fairly satisfactory degree of accordance.

  • PDF

오버행을 고려한 영구자석 동기 발전기의 동특성 해석 연구 (The Study on a Dynamic Analysis of Permanent Magnet Generator considering Overhang Effect)

  • 김기찬;이주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.58-62
    • /
    • 2006
  • The purpose of this paper is characteristic analysis of permanent magnet generator (PMG) for automatic voltage regulator (AVR)power of brush less synchronous generator. However, this PMG has a spoke type permanent magnet rotor with large overhang for high power density, characteristic analysis considering concentration effect of air-gap flux density due to the overhang should be performed. 30 transient finite element method (FEM)analysis is good solution for overhang parameter, but this method needs too much calculation time. In this paper, we examined the overhang effects based on overhang length and material of rotor core by using 20 and 30 static FEM analysis, and proposed 20 dynamic FEA model considering overhang parameter which gives good and rapid results. The proposed method is verified by the test results of no load, load and short circuit test.

  • PDF

고속 동기형 릴럭턴스 전동기의 회전자 설계 및 특성 해석 (Rotor Design and Characteristics Analysis of High Speed Reluctance Synchronous Motor)

  • 장석명;문정술;서진호;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.269-271
    • /
    • 1998
  • Reluctance Synchronous Motors(RSM) with new rotor shape are considered in this paper. Since the stator of a RSM is similar as that of an induction motor, attention is focused here on the rotor structure. We have designed the parameter of RSM and analyzed the characteristics of the electromagnetic energy conversion.

  • PDF

잡음에 강인한 음성 인식을 위한 환경 파라미터 보상에 관한 연구 (A Study on Environment Parameter Compensation Method for Robust Speech Recognition)

  • 홍미정;이호웅
    • 한국ITS학회 논문지
    • /
    • 제5권2호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 논문에서는 강인한 음성인식 기술의 하나인 모델 파라미터 변환 기법 중 Carnegie Mellon University(1996)에서 Moreno가 제안한 최신 VTS(Vector Taylor Series) 알고리즘을 이용하여 주어진 잡음 환경에서 실험하였다. 이러한 VTS 알고리즘의 성능평가를 위해서 기존의 잡음 처리 방법 중 CMN(Cepstral Mean Normalization) 기법을 도입하였으며, 데시벨별로 설정한 백색 잡음과 거리잡음을 환경잡음으로 주어졌을 때의 인식률을 비교하였다. 또한 기존 Moreno가 제안한 실험환경의 인식 결과와 본 논문에서의 실험결과를 비교 분석하였다. 인식 알고리즘으로는 실시간 구현이 가능한 이산HMM(Hidden Markov Model)을 사용하였다.

  • PDF