• 제목/요약/키워드: paper wastewater

검색결과 414건 처리시간 0.029초

초전도 자기분리에 의한 제지폐수의 정수 (Purification of wastewater from paper factory by superconducting magnetic separator)

  • 하동우;김태형;권준모;손명환;백승규;오상수;하홍수;고락길;김호섭;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.342-343
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to purity and recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purity the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purity rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

전도냉각형 고온초전도 자석을 이용한 제지폐수의 자기분리에 의한 정수 (Purification of wastewater from paper factory by cryo-cooled high-$T_c$ superconducting magnetic separator)

  • 하동우;김태형;손명환;권준모;백승규;오상수;고락길;하홍수;김호섭;김영훈;강채훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.4-4
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purify the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purify rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

침적 생물막법에 의한 제지폐수처리에 관한 연구 (A Study on the Treatment of Paper Making Wastewater Using Submerged biological Film Process)

  • 이태호;은종극
    • 환경위생공학
    • /
    • 제23권3호
    • /
    • pp.23-30
    • /
    • 2008
  • This study was carried out to get efficient of nutrient removal effects on the treatment of paper making wastewater using submerged biological film process. The concentration of average BOD at raw wastewater was $324mg/{\ell}$ and COD was $435mg/{\ell}$. The average BOD of effluent was maintained $24.2mg/{\ell}$ and average COD was $37mg/{\ell}$. The concentration of average T-N at raw wastewater was $16.5mg/{\ell}$ and T-P was $1.2mg/{\ell}$. The average T-P of effluent was maintained $2.3mg/{\ell}$ and average T-P was $0.08mg/{\ell}$. The concentration of average SS at influent wastewater was $263mg/{\ell}$. The average SS of effluent was maintained $28.2mg/{\ell}$. The result of this experiment was wastage sludge did generated and the removal efficiency of nutrients were kept equilibrium.

The Effect of Photocatalysis using $TiO_2$ and UV for COD Degradation of Wastewater in Linerboard Mill

  • Kang, Kwang-Ho;Kim, Hyoung-Jin
    • 펄프종이기술
    • /
    • 제40권5호
    • /
    • pp.53-59
    • /
    • 2008
  • This study was carried out to investigate the effect of photocatalysis using $TiO_2$ and UV applied for the COD reduction of wastewater in linerboard mill. Trials were done to obtain the optimum addition amounts of $TiO_2$ and $H_2O_2$ to the wastewater and find an appropriate pH condition for photocatalysis on $TiO_2$ for degrading COD. The photocatalytic reaction was applied to the wastewater collected after secondary activated sludge treatment in WWTP of linerboard mill. The optimum application of photocatalysis reaction was obtained under the addition conditions of 2 g/L of $TiO_2$ and 200 mg/L of $H_2O_2$ at pH 3.0, respectively. The removal efficiency of $SCOD_{Cr}$ by photocatalytic treatment was 86.4 % and higher than Fenton treatment in which removal efficiency was 67.4 %. It was concluded that the photocatalytic process using $TiO_2$ and UV could be applied to the wastewater treatment in linerboard mill and also to the dramatic drop-off in NBDCOD load from wastewater of tertiary treatment in WWTP.

막을 이용한 염색폐수의 재활용 연구 (A Study on Reuse System of Dyeing Wastewater using Membrane)

  • 서명포
    • 한국염색가공학회지
    • /
    • 제10권4호
    • /
    • pp.45-52
    • /
    • 1998
  • Reuse of wastewater become an important consideration to solve the environmental pollution problems in recent industriallzation and urbanization. Especially, he characteristic of dyeing process is subject to use much water and thus has serious problems for removal of color and organic pollutants in their wastewater. This report is divided into two main parts : The purpose of the first part was to determine if alkaline wastewater discharged from textile dyeing operation factory could be flocculated directly by Fenton oxidation method. This study was conducted to investigate Fenton reagent dose and reaction condition of Fenton method as pretreatment for dyeing wastewater in K dyeing industry were investigated. In the second part of this research, to treat dyeing wastewater it was found that the most effective way is to use ultrafiltation and reverse osmosis at the conditions of the pH 7.0~8.0 and operating pressure of $2.5~35kg_f/cm^2$. This paper is mainly dealt with the application on reuse system of dyeing wastewater treatment using ultrafiltration and reverse osmosis membranes. The results showed that dyeing wastewater could be reused by chemical, filter and membrane sequential treatment process.

  • PDF

순산소 활성오니 공정을 이용한 제지폐수의 처리특성 (Treatment Characteristics of Paper-mill Wastewater Using Pure Oxygen Activated Sludge Process)

  • 김성순;정태학
    • 상하수도학회지
    • /
    • 제13권4호
    • /
    • pp.27-34
    • /
    • 1999
  • An experimental study on improvement of the paper-mill wastewater treatment using the pure oxygen activated sludge process was conducted. The effects of hydraulic retention time(HRT) and BOD loading on organic removal efficiency were investigated. The BOD removal efficiencies were above 90% under all examined HRTs except for HRT of 3 hours. The increase of HRT from 3 hours to 6 hours, and to 12 hours significantly improved BOD and COD removal efficiencies, respectively. However, additional increase of HRT did not affect organic removal efficiency. F/M ratio change at fixed HRT did not affect organic removal efficiency. However, F/M ratio investigated in this study(0.11~1.98kgBOD/kgMLVSS/day) was 5 times greater in maximum than that of conventional activated sludge process, which implies that pure oxygen activated sludge process can treat wastewater with high organic strength. Under the same HRT, the volumetric BOD loading change cause no effect on organic removal efficiency also.

  • PDF

포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성 (Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment)

  • 곽동희;유승준;박종천
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

하수처리수의 농업용수 재이용에 관한 기초 연구 (Fundamental Study on the Wastewater Reuses for Agriculture)

  • 강문성;박승우;김상민
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.393-396
    • /
    • 2002
  • The objectives of the paper are to develop the infra-technologies for reclaiming the effluents from wastewater treatment plants and reusing for agriculture water. The Suwon wastewater treatment plant has been selected for wastewater reuse tests and the water quality and treatment efficiencies are investigated. Three levels of wastewater treatments that are the effluent from the plant, sand filtering, and ultra-violet treatment are applied in the pilot system. The randomized block method was applied to wastewater application to paddy rice with five treatments, three blocks, and two replica. The control was the plots with groundwater irrigation, the other treatments are to use polluted stream flow by pumping, in addition to three wastewater treatments. The block test plots and field plots have been monitored for the water quality, soil pollution, and health hazards during the crop stages.

  • PDF

하수처리수의 공업용수 재이용 활성화 방안 연구 (A Case Study on Utilization of Industrial Wastewater Reuse)

  • 이강옥;박정엽
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.17-24
    • /
    • 2020
  • This study analyzes economic feasibility by looking at the case of wastewater reclamation and reuse system of Osan, the only place currently operated in Korea, exploiting wastewater uniquely reused as industrial water. Furthermore, this paper examines the problem in wastewater recycling and present the method to expand the potential of using reclaimed water. Method to activate the reuse of wastewater as industrial water. First, it is required to provide self-governing body and demander with diverse information on this project so that they correctly recognize the reuse of wastewater as industrial water. Second, law should be amended so that the water quality requirement of reused water can be given in the national level to supply industrial water depending on right standard. Third, financial support should be expanded in diverse parts so that more private investment advantageous to investor can be made, for instance, BTL, BTO.

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • 공업화학
    • /
    • 제33권5호
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.